The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Abstract
Although single-channel electrode arrays implanted in the scala tympani of deaf patients are useful as an aid to lip reading and for distinguishing some environmental sounds, they do not transmit intelligible speech. However, multichannel electrode arrays, which take advantage of the cochlea's tonotopic organization, may be capable of generating the complex patterns of neural activity necessary for speech discrimination. In this study, multichannel electrodes were implanted in the cochleas of four volunteers, with access to the connecting wires made through the skin via a percutaneous connector. The major portion of the data presented is from two of these subjects: one has been bilaterally deaf since birth and the other has been unilaterally deaf for 15 years. Preliminary results of experiments with two more recently implanted subjects are described as well as experiments with a fifth volunteer who was implanted with five electrodes by House in 1969. Data on pitch and loudness discrimination as well as the effects of stimulation parameters on threshold, impedance, and electrode interaction are presented. Place pitch and periodicity pitch were observed in all five volunteers. The results of pitch-matching experiments with the unilaterally deaf volunteer were consistent with tonotopic maps of the cochlea, and experiments indicated that a pitch continuum may be achieved by combining place and periodicity pitch modulation. Preliminary experiments in tune recognition with one subject demonstrate his ability to recognize simple melodies based on periodicity pitch cues. These results, coupled with the finding that subjective sensations remain stable over the long-term, support the feasibility of providing artificial hearing with a multichannel cochlear stimulation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Self-citationDobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Self-citation“Braille” reading by a blind volunteer by visual cortex stimulation
DOBELLE, W. H., MLADEJOVSKY, M. G., EVANS, J. R., ROBERTS, T. S., & GIRVIN, J. P. (1976) · Nature · doi:10.1038/259111a0 · Cited by 253
Self-citation
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Music Perception with Cochlear Implants: A Review
McDermott, H. J. (2004) · Trends in Amplification · doi:10.1177/108471380400800203 · Cited by 549
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90077-1 · Cited by 364
Metadata
- Authors
- Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 1978-11
- Volume
- 87
- Issue
- 6_suppl
- Pages
- 5-39
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2402811972
- Cited by
- 334
- References
- 3
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man. https://app.cochat.ai/papers/10.1177/00034894780870s602
- The paper
- Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978). Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/00034894780870s602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.