Hydronic radiant cooling — preliminary assessment
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Radiant cooling systems can transfer peak cooling loads to off-peak hours, reducing peak power demand.
“Radiant cooling systems have the possibility of transferring peak cooling loads to off-peak hours, reducing peak power demand [237].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [237]
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180 · see citing works
Halawa, E., van Hoof, J., & Soebarto, V. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.040 · Cited by 133 · see citing works
A study of a polymer-based radiative cooling system
Meir, M. G., Rekstad, J. B., & LØvvik, O. M. (2002) · Solar Energy · doi:10.1016/s0038-092x(03)00019-7 · Cited by 125 · see citing works
Effects of different cooling principles on thermal sensation and physiological responses
Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.01.007 · Cited by 46 · see citing works
- Authors
- Feustel, H. E., & Stetiu, C.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 1995-08
- Volume
- 22
- Issue
- 3
- Pages
- 193-205
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2053331952
- Cited by
- 237
- References
- 0
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 16 · 2023: 9 · 2022: 15 · 2021: 16 · 2020: 14 · 2019: 12 · 2018: 11 · 2017: 17 · 2016: 12 · 2015: 14 · 2014: 16 · 2013: 16 · 2012: 14
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy and Buildings (publishedVersion)
- Funders
- U.S. Department of Energy
- U.S. Department of Veterans Affairs
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- all-air systems, air conditioning energy consumption, thermal comfort, cooling capacity, non-residential buildings
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review