Effects of different cooling principles on thermal sensation and physiological responses
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Schellen et al. [106] showed that operative temperature alone is not enough to assess thermal sensation under non-uniform conditions.
“Schellen et al. [106] also showed that operative temperature alone is not enough to assess thermal sensation under non-uniform conditions.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [106]
Thermal sensation of subjects could be well predicted by the PMV model in an experiment with active cooling through convection by mixing ventilation (uniform conditions), but not for the case in which active cooling through radiation by the floor was combined with displacement ventilation.
“Thermal sensation of subjects could be well predicted by the PMV model in an experiment with active cooling through convection by mixing ventilation (uniform conditions), but not for the case in which active cooling through radiation by the floor was combined with displacement ventilation.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [106]
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092 · see citing works
The assessment of the amount of fat in the human body from measurements of skinfold thickness
Durnin, J. V. G. A., & Rahaman, M. M. (1967) · British Journal Of Nutrition · doi:10.1079/bjn19670070 · Cited by 1,695 · see citing works
Awbi, H. (2002) · Routledge eBooks · doi:10.4324/9780203476307 · Cited by 902 · see citing works
Zhang, H., Arens, E. A., Huizenga, C., & Han, T. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.018 · Cited by 543 · see citing works
Zhang, H., Arens, E. A., Huizenga, C., & Han, T. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.020 · Cited by 533 · see citing works
Zhang, H., Arens, E. A., Huizenga, C., & Han, T. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.015 · Cited by 478 · see citing works
Partial- and whole-body thermal sensation and comfort—Part II: Non-uniform environmental conditions
Arens, E. A., Zhang, H., & Huizenga, C. (2006) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2005.11.027 · Cited by 437 · see citing works
Evaluation of wireless determination of skin temperature using iButtons
VANMARKENLICHTENBELT, W., DAANEN, H., WOUTERS, L., FRONCZEK, R., RAYMANN, R., SEVERENS, N., & VANSOMEREN, E. (2006) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.04.026 · Cited by 392 · see citing works
Thermal comfort and energy consumption of the radiant ceiling panel system.
Imanari, T., Omori, T., & Bogaki, K. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(98)00084-x · Cited by 334 · see citing works
Hydronic radiant cooling — preliminary assessment
Feustel, H. E., & Stetiu, C. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00922-k · Cited by 237 · see citing works
Miriel, J., Serres, L., & Trombe, A. (2002) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00087-x · Cited by 200 · see citing works
Personal Exposure in Displacement Ventilated Rooms
Brohus, H., & Nielsen, P. V. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-1-00003.x · Cited by 151 · see citing works
International standards for the indoor environment
Olesen, B. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00268.x · Cited by 149 · see citing works
Self-citationErgonomics. Evaluation of thermal strain by physiological measurements
(2004) · doi:10.3403/02995697 · Cited by 131 · see citing works
Floor heating and cooling combined with displacement ventilation: Possibilities and limitations
Causone, F., Baldin, F., Olesen, B. W., & Corgnati, S. P. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.08.001 · Cited by 122 · see citing works
Self-citationOlesen, B. W., & 경대호 (2008) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 118 · see citing works
Self-citationPassive cooling in a low-energy office building
Breesch, H., Bossaer, A., & Janssens, A. (2005) · Solar Energy · doi:10.1016/j.solener.2004.12.002 · Cited by 117 · see citing works
House, J. R., & Tipton, M. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0692-3 · Cited by 116 · see citing works
Energy saving possibilities with cooled-ceiling systems
Niu, J., Kooi, J. V. D., & Rhee, H.-J. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00937-x · Cited by 95 · see citing works
Indoor air quality in rooms with cooled ceilings.
Behne, M. J. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(98)00083-8 · Cited by 94 · see citing works
Gender differences in thermal comfort and mental performance at different vertical air temperatures
Hashiguchi, N., Feng, Y., & Tochihara, Y. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1158-7 · Cited by 92 · see citing works
Thermal sensation: a mathematical model based on neurophysiology
Kingma, B., Schellen, L., Frijns, A. A., & Lichtenbelt, W. D. V. M. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00758.x · Cited by 80 · see citing works
Self-citationIndoor climate in rooms with cooled ceiling systems
Niu, J., & Kooi, J. V. D. (1994) · Building and Environment · doi:10.1016/0360-1323(94)90024-8 · Cited by 55 · see citing works
Kildesø, J., Wyon, D., Skov, T., & Schneider, T. (1999) · Scandinavian Journal of Work, Environment and Health · doi:10.5271/sjweh.446 · Cited by 51 · see citing works
Skin-temperature gradients are a validated measure of fingertip perfusion
Sessler, D. I. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0812-8 · Cited by 44 · see citing works
Using large radiant panels for indoor climate conditioning
Roulet, C.-A., Rossy, J.-P., & Roulet, Y. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(98)00079-6 · Cited by 39 · see citing works
Airflow characteristics in the occupied zone of rooms with displacement ventilation
Melikov, A. K., Langkilde, G., & Derbiszewski, B. (1990) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 37 · see citing works
Schellen, L., Loomans, M. G. L. C., Lichtenbelt, V. W. D. M., Frijns, A. A., & de Wit, M. H. (2010) · TU/e Research Portal · Cited by 7 · see citing works
Self-citation
Flagged first, then by citations
3 of the 35 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907 · see citing works
Drivers of diversity in human thermal perception – A review for holistic comfort models
Schweiker, M., Huebner, G. M., Kingma, B. R. M., Kramer, R., & Pallubinsky, H. (2018) · Temperature · doi:10.1080/23328940.2018.1534490 · Cited by 231 · see citing works
Thermal comfort in buildings using radiant vs. all-air systems: A critical literature review
Karmann, C., Schiavon, S., & Bauman, F. S. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.10.020 · Cited by 187 · see citing works
Zhang, C., Pomianowski, M. Z., Heiselberg, P., & Yu, T. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110094 · Cited by 182 · see citing works
Thermal comfort of heterogeneous and dynamic indoor conditions — An overview
Mishra, A. K., Loomans, M. G. L. C., & Hensen, J. L. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.016 · Cited by 167 · see citing works
Self-citationXia, W., Fei, X., Wang, Q., Lu, Y., Innocent, M. T., Zhou, J., Yu, S., Xiang, H., & Zhu, M. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126369 · Cited by 104 · see citing works
Shan, X., Zhou, J. Z., Chang, V. W.-C., & Yang, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.03.025 · Cited by 101 · see citing works
A model to compare convective and radiant heating systems for intermittent space heating
Wang, Z., Luo, M., Yang, G., Lin, B., & Zhu, Y. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.01.088 · Cited by 97 · see citing works
Comparing temperature and acoustic satisfaction in 60 radiant and all-air buildings
Karmann, C., Schiavon, S., Graham, L. T., Raftery, P., & Bauman, F. S. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.10.024 · Cited by 64 · see citing works
A review of human thermal comfort experiments in controlled and semi-controlled environments
Craenendonck, S. V., Lauriks, L., Vuye, C., & Kampen, J. K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.053 · Cited by 62 · see citing works
Wu, Z., Li, N., & Schiavon, S. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109512 · Cited by 56 · see citing works
A New Personalized Cooling Protocol to Activate Brown Adipose Tissue in Young Adults
Martínez‐Téllez, B., Sánchez‐Delgado, G., García‐Rivero, Y., Alcántara, J. M. A., Martinez-Avila, W. D., Muñoz-Hernandez, M. V., Olza, J., Boon, M. R., Rensen, P. C. N., Elvira, J. M. L., et al. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00863 · Cited by 54 · see citing works
Zhou, X. J., Liu, Y., Zhang, J., Ye, L., & Luo, M. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111917 · Cited by 52 · see citing works
Chatterjee, A., & Khovalyg, D. M. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110766 · Cited by 52 · see citing works
He, Y., Li, N., & Huang, Q. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.058 · Cited by 49 · see citing works
Du, H., Lian, Z., Lai, D., Duanmu, L., Zhai, Y., Cao, B., Zhang, Y., Zhou, X. J., Wang, Z., Zhang, X., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108685 · Cited by 41 · see citing works
Yau, Y. H., Toh, H. S., Chew, B. T., & Ghazali, N. N. N. (2022) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-022-11585-0 · Cited by 35 · see citing works
O’Donovan, A., O’Sullivan, P. D., & Murphy, M. D. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.11.049 · Cited by 32 · see citing works
Liu, J., Kim, M. K., & Srebric, J. (2021) · Indoor and Built Environment · doi:10.1177/1420326x211040853 · Cited by 30 · see citing works
Cooling ceiling assisted by desk fans for comfort in hot-humid environment
He, Y., Wang, X., Li, N., He, M., He, D., & Wang, K. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.037 · Cited by 28 · see citing works
Martínez‐Téllez, B., Sánchez‐Delgado, G., Acosta, F. M., Alcántara, J. M. A., Boon, M. R., Rensen, P. C. N., & Ruiz, J. R. (2017) · Scientific Reports · doi:10.1038/s41598-017-10444-5 · Cited by 25 · see citing works
Experimental Evaluation of Radiant Heating Ceiling Systems Based on Thermal Comfort Criteria
Safizadeh, M. R., Schweiker, M., & Wagner, A. (2018) · Energies · doi:10.3390/en11112932 · Cited by 24 · see citing works
Li, X., Zhou, B., Shen, L., & Wu, Z. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20903375 · Cited by 23 · see citing works
Wu, Y., Zhang, Z., Liu, H., Cui, H., & Cheng, Y. C. (2022) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2022.103389 · Cited by 20 · see citing works
Skin temperature response to a liquid meal intake is different in men than in women
Martínez‐Téllez, B., Ortiz-Alvarez, L., Sánchez‐Delgado, G., Xu, H., Acosta, F. M., Merchán-Ramírez, E., Muñoz-Hernández, V., Martinez-Avila, W. D., Contreras-Gomez, M. A., Gil, Á., et al. (2018) · Clinical Nutrition · doi:10.1016/j.clnu.2018.05.026 · Cited by 20 · see citing works
Cui, M., Ning, B., Wu, X., Kim, M. K., Yang, B. T., Tian, Z., & Liu, J. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.102544 · Cited by 19 · see citing works
Subjective assessment of thermal comfort by radiant cooling in a tropical hot humid climate
Aryal, A., Chaiwiwatworakul, P., Chirarattananon, S., & Wongsuwan, W. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111601 · Cited by 17 · see citing works
Zhang, S., Wang, R., & Lin, Z. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.111155 · Cited by 17 · see citing works
Martínez‐Téllez, B., Xu, H., Sánchez‐Delgado, G., Acosta, F. M., Rensen, P. C. N., Elvira, J. M. L., & Ruiz, J. R. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00238.2018 · Cited by 14 · see citing works
Study on Human Physiological Adaptation of Thermal Comfort Under Building Environment
Lin, Y., Yang, L., Zheng, W., & Ren, Y. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.09.157 · Cited by 12 · see citing works
Kiil, M., Simson, R., Thalfeldt, M., & Kurnitski, J. (2020) · Atmosphere · doi:10.3390/atmos11020127 · Cited by 11 · see citing works
Pai, A., & Kumar, B. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113593 · Cited by 8 · see citing works
Scale of human thermal sensation using seasonal anchor method: A Chinese case study
Yu, D., & Shan, L. I. (2019) · 自然资源学报 · doi:10.31497/zrzyxb.20190806 · Cited by 7 · see citing works
Experimental evaluation of subjective thermal perceptions for sewing activity
Chowdhury, S., Hamada, Y., & Ahmed, K. S. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.05.006 · Cited by 5 · see citing works
Impact of outdoor air temperature during hostel-classroom commute on student’s classroom performance
Das, S., Mishra, A. K., & Subudhi, S. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115716 · Cited by 4 · see citing works
Evaluation of Skin Hardness as a Physiological Sign of Human Thermal Status
Yoon, S., Sim, J. K., Park, N., & Cho, Y.-H. (2018) · Scientific Reports · doi:10.1038/s41598-018-30206-1 · Cited by 4 · see citing works
Fan, X., Silvestri, A., Lydon, G. P., Wargocki, P. L., Borkowski, E., & Schlueter, A. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116236 · Cited by 3 · see citing works
Seo, R., Rhee, K.-N., & Jung, G.-J. (2024) · Indoor and Built Environment · doi:10.1177/1420326x241286888 · Cited by 2 · see citing works
Incorporating cooling and ventilation effects into a single IEQ indicator
Prek, M., Krese, G., & Lampret, Ž. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911102011 · Cited by 1 · see citing works
The Effect of Genders on the Perception of the Combined Effect of Local Discomfort Parameters
András-Tövissi, B., & Kajtár, L. (2021) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.18249 · Cited by 1 · see citing works
Krüger, E. L., Fernandes, L. C., & Erell, E. (2023) · Green energy and technology · doi:10.1007/978-3-031-24208-3_6 · Cited by 1 · see citing works
Variation in time of the perception of local discomfort parameters
András-Tövissi, B., Kajtár, L., & Nyers, J. M. (2021) · Thermal Science · doi:10.2298/tsci210419231a
Impact of gradual step changes in temperature on thermal comfort in hot climates
Barnawi, K. Z. (2024) · Queensland University of Technology · doi:10.5204/thesis.eprints.248958
Li, H., Yu, A., Li, M., Cai, Z., Chen, L., & Sun, J. (2026) · Journal of Energy Storage · doi:10.1016/j.est.2026.122667
Riccardi, B., Marigo, M., Tognon, G., Carli, M. D., & Zarrella, A. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.108365
- Authors
- Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M.
- Affiliations
- Avans University of Applied Sciences (NL)
- Eindhoven University of Technology (NL)
- Technical University of Denmark (DK)
- Maastricht University Medical Centre (NL)
- Corresponding author
- Schellen, Lisje
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 62
- Pages
- 116-125
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2155112914
- Cited by
- 46
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 6 · 2016: 4 · 2015: 3
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy and Buildings (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Funders
- Agentschap NL
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Keywords
- thermal comfort, thermal sensation, passive cooling, active cooling, mixing ventilation, displacement ventilation, radiant cooling, floor cooling, operative temperature, thermal discomfort
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review