Cited by 46Building Energy and Comfort OptimizationUrban Heat Island MitigationThermoregulation and physiological responses

Effects of different cooling principles on thermal sensation and physiological responses

Schellen, Lisje, Loomans, Marcel G.L.C., de Wit, Martin H., Olesen, Bjarne W., Lichtenbelt, Wouter D. van Marken·2013·Energy and Buildings

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2013.01.007

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Schellen et al. [106] showed that operative temperature alone is not enough to assess thermal sensation under non-uniform conditions.

    “Schellen et al. [106] also showed that operative temperature alone is not enough to assess thermal sensation under non-uniform conditions.”
  • Thermal sensation of subjects could be well predicted by the PMV model in an experiment with active cooling through convection by mixing ventilation (uniform conditions), but not for the case in which active cooling through radiation by the floor was combined with displacement ventilation.

    “Thermal sensation of subjects could be well predicted by the PMV model in an experiment with active cooling through convection by mixing ventilation (uniform conditions), but not for the case in which active cooling through radiation by the floor was combined with displacement ventilation.”

Cites

Flagged first, then by citations

3 of the 35 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M.
Affiliations
  • Avans University of Applied Sciences (NL)
  • Eindhoven University of Technology (NL)
  • Technical University of Denmark (DK)
  • Maastricht University Medical Centre (NL)
Corresponding author
Schellen, Lisje
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2013-07
Volume
62
Pages
116-125
ISSN
0378-7788 (ISSN-L)
OpenAlex
W2155112914
Cited by
46
References
35
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 2 · 2018: 7 · 2017: 6 · 2016: 4 · 2015: 3
FWCI
4.06
Type
journal article
Language
en
Open access
closed
Locations
  • Energy and Buildings (publishedVersion)
  • TU/e Research Portal (publishedVersion)
  • TU/e Research Portal (submittedVersion)
Funders
Agentschap NL
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
Keywords
thermal comfort, thermal sensation, passive cooling, active cooling, mixing ventilation, displacement ventilation, radiant cooling, floor cooling, operative temperature, thermal discomfort

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review