The impacts of the thermal radiation field on thermal comfort, energy consumption and control—A critical overview
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Halawa et al. [105] review found that sample sizes in studies on the thermal radiation field are small, studies are predominantly confined to climate chamber experiments, and results are not consistent.
“Their literature review reveals that sample sizes are small, studies are predominantly confined to climate chamber experiments, and results are not consistent.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [105]
The use of operative temperature as a measure of the combined effect of mean radiant and air temperatures is highly questionable for many cases, especially with respect to radiation asymmetry.
“They show that the use of operative temperature as a measure of the combined effect of mean radiant and air temperatures is highly questionable for many cases, especially with respect to radiation asymmetry.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [105]
The radiant field is mostly perceived in the combined form of radiant asymmetry and mean radiant temperature (MRT), which is a result of the asymmetry.
“Moreover, the radiant field is mostly perceived in the combined form of radiant asymmetry and mean radiant temperature (MRT), which is a result of the asymmetry.”
From Drivers of diversity in human thermal perception – A review for holistic comfort models (2018) · cites this paper as [105]
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092 · see citing works
Thermal Radiation Heat Transfer
Ellison, G. (2010) · CRC Press eBooks · doi:10.1201/b12772-12 · Cited by 5,423 · see citing works
Thermal comfort: Analysis and applications in environmental engineering
Fanger, P. O. (1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,515 · see citing works
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,398 · see citing works
(1998) · eScholarship (California Digital Library) · Cited by 1,934 · see citing works
Adaptive thermal comfort and sustainable thermal standards for buildings
Nicol, F., & Humphreys, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00006-3 · Cited by 1,864 · see citing works
Extension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853 · see citing works
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733 · see citing works
Self-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534 · see citing works
Progress in thermal comfort research over the last twenty years
de Dear, R., AKIMOTO, T., Arens, E. A., Brager, G. S., Cândido, C., Cheong, D. K. W., Li, B., Nishihara, N., Sekhar, C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 524 · see citing works
Developing an adaptive control algorithm for Europe
McCartney, K. J., & Nicol, F. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00013-0 · Cited by 460 · see citing works
A review into thermal comfort in buildings
Taleghani, M., Tenpierik, M., Kurvers, S. R., & van den Dobbelsteen, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.05.050 · Cited by 358 · see citing works
The adaptive approach to thermal comfort: A critical overview
Halawa, E., & van Hoof, J. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.04.011 · Cited by 260 · see citing works
Self-citationManually-operated window shade patterns in office buildings: A critical review
O’Brien, W., Kapsis, K., & Athienitis, A. K. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.10.003 · Cited by 259 · see citing works
Hydronic radiant cooling — preliminary assessment
Feustel, H. E., & Stetiu, C. (1995) · Energy and Buildings · doi:10.1016/0378-7788(95)00922-k · Cited by 237 · see citing works
Radiant Floor Heating In Theory and Practice
Olesen, B. W. (2002) · ASHRAE journal · Cited by 237 · see citing works
Sitton, R. (2014) · Columbia University Press eBooks · doi:10.7312/columbia/9780231165785.003.0040 · Cited by 231 · see citing works
Jones, W. P. (2007) · Routledge eBooks · doi:10.4324/9780080498942 · Cited by 220 · see citing works
Expectations of indoor climate control
Fountain, M., Brager, G. S., & de Dear, R. (1996) · Energy and Buildings · doi:10.1016/s0378-7788(96)00988-7 · Cited by 210 · see citing works
Comfort limits for asymmetric thermal radiation
Fanger, P. O., Ipsen, B. M., Langkilde, G., et al. (1985) · Energy and Buildings · doi:10.1016/0378-7788(85)90006-4 · Cited by 199 · see citing works
Thermal comfort in hospitals – A literature review
Khodakarami, J., & Nasrollahi, N. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.054 · Cited by 175 · see citing works
Effects of radiant temperature on thermal comfort
Atmaca, İ., Kaynaklı, Ö., & Yiğit, A. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.08.009 · Cited by 173 · see citing works
Thermal comfort: research and practice
van Hoof, J. (2009) · Frontiers in bioscience · doi:10.2741/3645 · Cited by 173 · see citing works
Taylor, S. T. (1990) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 166 · see citing works
The Globe Thermometer in Studies of Heating and Ventilation
Bedford, T., & Warner, C. G. (1934) · Epidemiology and Infection · doi:10.1017/s0022172400043242 · Cited by 128 · see citing works
Alfano, F. R. D., Dell’Isola, M., Palella, B. I., Riccio, G., & Russi, A. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.01.026 · Cited by 123 · see citing works
Henze, G. P., Felsmann, C., Kalz, D. E., et al. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.01.014 · Cited by 117 · see citing works
Sakoi, T., Tsuzuki, K., Kato, S., et al. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.10.050 · Cited by 115 · see citing works
Lehmann, B., Dorer, V., Gwerder, M., et al. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.08.010 · Cited by 115 · see citing works
The Measurement of Radiant Heat in Relation to Human Comfort.
Vernon, H. M. (1930) · Journal of Industrial Hygiene · Cited by 92 · see citing works
Hodder, S., Loveday, D. L., Parsons, K., et al. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00038-8 · Cited by 61 · see citing works
Olesen, S. (1972) · Medical Entomology and Zoology · Cited by 50 · see citing works
Analysis of mean radiant temperature and thermal comfort
Gan, G. (2001) · Building Services Engineering Research and Technology · doi:10.1191/014362401701524154 · Cited by 44 · see citing works
The Effective Radiant Field and Operative Temperature Necessary for Comfort with Radiant Heating
Gagge, A. P. (1967) · ASHRAE winter conference papers · Cited by 41 · see citing works
Optimum control policies to minimize energy use in HVAC systems
Kaya, A., Alexander, S., Chen, C. S., et al. (1982) · ASHRAE winter conference papers · Cited by 32 · see citing works
Combined effect of two local discomfort parameters studied with a thermal manikin and human subjects
Barna, E., & Bánhidi, L. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.05.015 · Cited by 27 · see citing works
Chrenko, F. A. (1953) · Cited by 26 · see citing works
Integrating radiant/operative temperature controls into building energy simulations
Niu, J., & Burnett, J. (1998) · ASHRAE winter conference papers · Cited by 26 · see citing works
Measured radiant thermal fields in industrial spaces served by high intensity infrared heater
Dudkiewicz, E., & Jezowiecki, J. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.07.005 · Cited by 24 · see citing works
Required and Current Thermal Conditions for Occupants in Iranian Hospitals
Khodakarami, J., & Knight, I. P. (2008) · Science and Technology for the Built Environment · doi:10.1080/10789669.2008.10391002 · Cited by 20 · see citing works
McIntyre, D. A. (1974) · Building Science · doi:10.1016/0007-3628(74)90024-3 · Cited by 19 · see citing works
Sensitivity and Discomfort Associated with Overhead Thermal Radiation
McIntyre, D. A. (1977) · Ergonomics · doi:10.1080/00140137708931628 · Cited by 17 · see citing works
Al-Othmani, M., Ghali, K., & Ghaddar, N. (2009) · Science and Technology for the Built Environment · doi:10.1080/10789669.2009.10390869 · Cited by 14 · see citing works
Effect on Thermal Comfort of Radiant Heat Exchange Near Single Glazed Windows
Rowe, D. (2003) · Architectural Science Review · doi:10.1080/00038628.2003.9696961 · Cited by 12 · see citing works
Assessing indoor thermal climate — A critical discussion
Kähkönen, E., & Ilmarinen, R. (1989) · Environment International · doi:10.1016/0160-4120(89)90072-x · Cited by 8 · see citing works
Improving thermal comfort conditions by accounting for the mean radiant temperature
Halawa, E., & Marquand, C. J. (1994) · International Journal of Ambient Energy · doi:10.1080/01430750.1994.9675635 · Cited by 7 · see citing works
Self-citationOptimum Control of HVAC System to Save Energy
Kaya, A. (1981) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)63950-8 · Cited by 6 · see citing works
Discomfort Caused by Sitting Next to a Cold Window: Simulated Railway Carriage at Night
Underwood, P., & Parsons, K. (2023) · Taylor & Francis eBooks · doi:10.1201/9781003419969-52 · Cited by 3 · see citing works
Su, Chih-Chun, Hsia, et al. (2010) · 哈尔滨工业大学学报:英文版 · Cited by 1 · see citing works
Chih, S. (2010) · 哈尔滨工业大学学报:英文版 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907 · see citing works
Drivers of diversity in human thermal perception – A review for holistic comfort models
Schweiker, M., Huebner, G. M., Kingma, B. R. M., Kramer, R., & Pallubinsky, H. (2018) · Temperature · doi:10.1080/23328940.2018.1534490 · Cited by 231 · see citing works
Thermal comfort of heterogeneous and dynamic indoor conditions — An overview
Mishra, A. K., Loomans, M. G. L. C., & Hensen, J. L. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.016 · Cited by 167 · see citing works
- Authors
- Halawa, E., van Hoof, J., & Soebarto, V.
- Affiliations
- Charles Darwin University (AU)
- The University of Adelaide (AU)
- Corresponding author
- Halawa, Edward
- ORCID
- Soebarto, Veronica
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 37
- Pages
- 907-918
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2030598812
- Cited by
- 133
- References
- 50
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 17 · 2023: 17 · 2022: 12 · 2021: 9 · 2020: 10 · 2019: 8 · 2018: 12 · 2017: 9 · 2016: 9 · 2015: 4 · 2014: 2
- FWCI
- 11.85
- Type
- journal article
- Language
- en
- Open access
- green
- surfsharekit.nl
- Licence
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Keywords
- thermal radiation, mean radiant temperature, radiation asymmetry, thermal comfort, operative temperature, air conditioning control, building energy consumption
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review