The European Spine Phantom — a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT

Kalender, Willi A., Felsenberg, Dieter, Genant, Harry K., Fischer, Manfred, Dequeker, Jan, Reeve, Jonathan·1995·European Journal of Radiology

Abstract

The lack of standardization in bone mineral measurements of the lumbar spine and other skeletal sites is generally recognized as an important and unresolved issue. We report and discuss efforts at standardization and cross-calibration of DXA and QCT equipment. We have designed and tested a geometrically defined, semi-anthropomorphic phantom, the European Spine Phantom (ESP). It contains a spine insert consisting of three vertebrae of increasing bone mineral densities and thicknesses of cortical structures; the respective parameters are given in tabular form for the final phantom design. Results for cross-calibration with the ESP compare well with patient results. Measurements on the first 30 phantoms confirmed that the ESP can be manufactured with a variation of about 1%. We conclude that the ESP is suitable for daily quality assurance, cross-calibration of instruments and universal standardization. The ESP was used to establish standardized BMD (sBMD) units for DXA equipment going into effect in late 1995. Its acceptance by manufacturers as a calibration standard for DXA and QCT measurements appears imminent.

Integrity signals

Registry

Crossref · 10.1016/0720-048x(95)00631-y

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A previous experimental study with spectral localizer radiographs from PCD-CT using the European Spine Phantom showed that spectral localizer radiographs were more accurate than DXA at higher bone density.

    “A previous experimental study with spectral localizer radiographs from PCD-CT using the established European Spine Phantom21 showed that spectral localizer radiographs were more accurate that DXA at higher bone density.13”

Cited by

Sorted by citations

Authors
Kalender, W. A., Felsenberg, D., Genant, H. K., Fischer, M., Dequeker, J., & Reeve, J.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • University of California, San Francisco (US)
  • KU Leuven (BE)
  • University of Cambridge (GB)
Corresponding author
Kalender, Willi A.
Venue
European Journal of Radiology
Publisher
Elsevier BV
Published
1995-07
Volume
20
Issue
2
Pages
83-92
ISSN
0720-048X (ISSN-L)
OpenAlex
W2023173649
Cited by
263
References
0
Citations by year
2026: 8 · 2025: 6 · 2024: 7 · 2023: 7 · 2022: 4 · 2021: 11 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 14 · 2016: 5 · 2015: 6 · 2014: 15 · 2013: 9 · 2012: 8
FWCI
10.64
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
lumbar spine bone mineral density, dual-energy X-ray absorptiometry, quantitative computed tomography, quality assurance, cross-calibration, bone densitometry
MeSH terms
Adult, Aged, Aged, 80 and over, Humans, Middle Aged, Models, Anatomic, Osteoporosis, Quality Control, Reference Standards, Spine, Tomography, X-Ray Computed, Absorptiometry, Photon, Bone Density

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review