DXA-equivalent quantification of bone mineral density using dual-layer spectral CT scout scans
Abstract
Objectives To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. Methods A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. Results Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p Conclusions Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. Key points • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to au…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These findings are in line with previous reports using quantitative CT, dual-energy CT, and dual-energy CT-based localizer radiographs.
“These findings are in line with previous reports using quantitative CT,18 dual-energy CT,18–20 and dual-energy CT–based localizer radiographs.10”
From In Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT (2025) · cites this paper as [10]
Alternatively, 1 localizer radiograph obtained with a dual-layer CT scanner enables quantification of the aBMD.
“Alternatively, 1 localizer radiograph obtained with a dual-layer CT scanner enables quantification of the aBMD.10”
From In Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT (2025) · cites this paper as [10]
Cites
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947 · see citing works
Osteoporosis in the European Union: medical management, epidemiology and economic burden
Hernlund, E., Svedbom, A., Ivergård, M., Compston, J., Cooper, C. C., Stenmark, J., McCloskey, E. V., Jönsson, B., & Kanis, J. A. (2013) · Archives of Osteoporosis · doi:10.1007/s11657-013-0136-1 · Cited by 2,674 · see citing works
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,016 · see citing works
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,608 · see citing works
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,341 · see citing works
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 951 · see citing works
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 454 · see citing works
Radiation exposure in X-ray-based imaging techniques used in osteoporosis
Damilakis, J. E., Adams, J. E., Guglielmi, G., & Link, T. M. (2010) · European Radiology · doi:10.1007/s00330-010-1845-0 · Cited by 355 · see citing works
Epidemiology, treatment and costs of osteoporosis in Germany—the BoneEVA Study
Häussler, B., Gothe, H., Göl, D., Glaeske, G., Pientka, L., & Felsenberg, D. (2006) · Osteoporosis International · doi:10.1007/s00198-006-0206-y · Cited by 342 · see citing works
Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
Yu, E. W., Thomas, B. J., Brown, J. K., & Finkelstein, J. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.506 · Cited by 300 · see citing works
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels
Gutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S. G., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282 · see citing works
Kalender, W. A., Felsenberg, D., Genant, H. K., Fischer, M., Dequeker, J., & Reeve, J. (1995) · European Journal of Radiology · doi:10.1016/0720-048x(95)00631-y · Cited by 263 · see citing works
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, A., Symons, R., Sandfort, V., Mallek, M., Fuld, M. K., Henderson, G., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2016) · Radiology · doi:10.1148/radiol.2016152601 · Cited by 208 · see citing works
(2012) · Radiology · doi:10.1148/radiol.2633201203 · Cited by 174 · see citing works
(2012) · Radiology · doi:10.1148/radiol.2631201201 · Cited by 164 · see citing works
Cormode, D. P., Si-Mohamed, S. A., Bar-Ness, D., Sigovan, M., Naha, P. C., Balegamire, J., Lavenne, F., Coulon, P., Roessl, E., Bartels, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-04659-9 · Cited by 150 · see citing works
Spectral Photon-counting CT: Initial Experience with Dual–Contrast Agent K-Edge Colonography
Muenzel, D., Bar-Ness, D., Roessl, E., Blevis, I. M., Bartels, M., Fingerle, A. A., Ruschke, S., Coulon, P., Daerr, H., Kopp, F. K., et al. (2016) · Radiology · doi:10.1148/radiol.2016160890 · Cited by 143 · see citing works
Self-citationLongitudinal Trends in Use of Bone Mass Measurement Among Older Americans, 1999–2005
Curtis, J. R., Carbone, L. D., Cheng, H. M., Hayes, B. L., Laster, A. J., Matthews, R., Saag, K. G., Sepanski, R. J., Tanner, S. B., & Delzell, E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080232 · Cited by 132 · see citing works
Wu, X., Liao, E. Y., Huang, G., Dai, R. C., & Zhang, H. (2003) · Calcified Tissue International · doi:10.1007/s00223-002-1069-7 · Cited by 122 · see citing works
Material Separation with Dual-Layer CT
Carmi, R., Naveh, G., & Altman, A. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2005.1596697 · Cited by 110 · see citing works
Brett, A., & Brown, J. K. (2015) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.08.006 · Cited by 103 · see citing works
van Hamersvelt, R. W., Schilham, A. M. R., Engelke, K., den Harder, A. M., de Keizer, B., Verhaar, H. J., Leiner, T., de Jong, P. A., & Willemink, M. J. (2017) · European Radiology · doi:10.1007/s00330-017-4801-4 · Cited by 94 · see citing works
Dangelmaier, J., Bar-Ness, D., Daerr, H., Muenzel, D., Si-Mohamed, S. A., Ehn, S., Fingerle, A. A., Kimm, M. A., Kopp, F. K., Boussel, L., et al. (2018) · European Radiology · doi:10.1007/s00330-017-5252-7 · Cited by 94 · see citing works
Self-citationAssessment of quantification accuracy and image quality of a full‐body dual‐layer spectral CT system
Ehn, S., Sellerer, T., Muenzel, D., Fingerle, A. A., Kopp, F. K., Duda, M., Mei, K., Renger, B. C., Herzen, J., Dangelmaier, J., et al. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12243 · Cited by 82 · see citing works
Self-citation30 years of DXA technology innovations
Glüer, C. (2017) · Bone · doi:10.1016/j.bone.2017.05.020 · Cited by 53 · see citing works
Assessment of patient dose from CT localizer radiographs
Schmidt, B. T., Saltybaeva, N., Kolditz, D., & Kalender, W. A. (2013) · Medical Physics · doi:10.1118/1.4813296 · Cited by 50 · see citing works
Mei, K., Schwaiger, B. J., Kopp, F. K., Ehn, S., Gersing, A. S., Kirschke, J. S., Muenzel, D., Fingerle, A. A., Rummeny, E. J., Pfeiffer, F., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-17855-4 · Cited by 42 · see citing works
Self-citationVlassenbroek, A. (2010) · Medical radiology · doi:10.1007/174_2010_56 · Cited by 40 · see citing works
Jia, Q., Hu, X., Shi, D., Zhang, Y., Sun, M., Wang, J., Mi, K., & Zhu, G. (2017) · Scientific Reports · doi:10.1038/srep44966 · Cited by 40 · see citing works
Schwaiger, B. J., Kopperdahl, D. L., Nardo, L., Facchetti, L., Gersing, A. S., Neumann, J., Lee, K. J., Keaveny, T. M., & Link, T. M. (2017) · Bone · doi:10.1016/j.bone.2017.04.008 · Cited by 33 · see citing works
Self-citationMonitoring Changes in Bone Density
Bonnick, S. L. (2008) · Women s Health · doi:10.2217/17455057.4.1.89 · Cited by 27 · see citing works
Aubert, B., Vázquez, C., Cresson, T., Stefan Parent, D., & de Guise, J. A. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493535 · Cited by 24 · see citing works
Optimizing radiation exposure for CT localizer radiographs
Bohrer, E., Schäfer, S., Mäder, U., Noël, P. B., Krombach, G. A., & Fiebich, M. (2016) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2016.09.004 · Cited by 12 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Nowak, T., Eberhard, M., Schmidt, B., Frey, D., Distler, O., Saltybaeva, N., Alkadhi, H., & Euler, A. (2021) · Radiology · doi:10.1148/radiol.2020202767 · Cited by 41 · see citing works
Euler, A., Nowak, T., Bucher, B., Eberhard, M., Schmidt, B., Flohr, T. G., Frey, D., Distler, O., & Alkadhi, H. (2021) · Investigative Radiology · doi:10.1097/rli.0000000000000781 · Cited by 19 · see citing works
Woisetschläger, M., Hägg, M., & Spångéus, A. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-1013 · Cited by 17 · see citing works
Zopfs, D., Lennartz, S., Zaeske, C., Merkt, M., Laukamp, K. R., Reimer, R. P., Maintz, D. C., Borggrefe, J., & Hokamp, N. G. (2020) · British Journal of Radiology · doi:10.1259/bjr.20190992 · Cited by 16 · see citing works
Liu, Z., Zhang, Y., Liu, Z., Kong, J., Huang, D., Zhang, X., & Jiang, Y. (2021) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001168 · Cited by 16 · see citing works
A Comprehensive Review on Real-Time Viscosity and Density Measuring Sensors
Kumari, K., Sathiya, S., & Sikander, A. (2025) · MAPAN · doi:10.1007/s12647-024-00799-2 · Cited by 14 · see citing works
Photon-counting CT: Scouting for Quantitative Imaging Biomarkers
Pourmorteza, A. (2020) · Radiology · doi:10.1148/radiol.2020203896 · Cited by 11 · see citing works
A machine learning method for precise detection of spine bone mineral density
Wang, J., Yang, G., Liu, S., Qiao, R., Cao, Y., Fan, B., Yang, H., & Lyu, F. (2024) · Alexandria Engineering Journal · doi:10.1016/j.aej.2024.04.059 · Cited by 9 · see citing works
Accuracy, agreement, and reliability of DECT-derived vBMD measurements: an initial ex vivo study
Qin, L., Huang, J., Yu, P., Yan, J., Ge, Y., Lü, Y., Yan, F., Wang, L., & Du, L. (2020) · European Radiology · doi:10.1007/s00330-020-07118-8 · Cited by 9 · see citing works
Quantitative calcium-based assessment of osteoporosis in dual-layer spectral CT
Do, T. D., Rahn, S., Melzig, C., Heußel, C. P., Stiller, W., Kauczor, H., Weber, T. F., & Skornitzke, S. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111606 · Cited by 9 · see citing works
Moser, L. J., Klambauer, K., Diaz Machicado, M. C., Frey, D., Mergen, V., Eberhard, M., Nowak, T., Schmidt, B., Flohr, T., Distler, O., et al. (2025) · Investigative Radiology · doi:10.1097/rli.0000000000001159 · Cited by 8 · see citing works
Kim, J.-E., Yoo, H. J., Chae, H.-D., Choi, J.-Y., Hong, S. H., Kang, J. H., & Yeoh, H. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.19.22697 · Cited by 8 · see citing works
Assessment the Accuracy of Densitometry Measurements Using DMA PP2 Phantom
Petraikin, A. V., Смолярчук, М. Я., Petryaykin, F. A., Низовцова, Л. А., Artyukova, Z. R., Анатольевна, С. К., Akhmad, E. S., Семенов, Д. С., Vladzymyrsky, A. V., & Morozov, S. P. (2019) · Traumatology and Orthopedics of Russia · doi:10.21823/2311-2905-2019-25-3-124-134 · Cited by 7 · see citing works
Zhou, S., Zhao, S., Chang, J. R., Dong, H., Du, L., Lü, Y., Zhang, Q., Zhang, Y., Chen, Z., Nowak, T., et al. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.01.038 · Cited by 6 · see citing works
Namikawa, T., Yokota, K., Iwabu, J., Munekage, M., Uemura, S., Tsujii, S., Maeda, H., Kitagawa, H., Karashima, T., Kumon, M., et al. (2020) · JGH Open · doi:10.1002/jgh3.12347 · Cited by 6 · see citing works
Neumann, J., Nowak, T., Schmidt, B. T., & von Zanthier, J. (2024) · Diagnostics · doi:10.3390/diagnostics14121262 · Cited by 6 · see citing works
Hammel, J., Birnbacher, L., Campbell, G. M., Coulon, P., Ushakov, L., Pfeiffer, F., Makowski, M. R., Kirschke, J. S., & Pfeiffer, D. (2023) · European Radiology Experimental · doi:10.1186/s41747-023-00356-7 · Cited by 5 · see citing works
Self-citationGruenewald, L. D., Booz, C., Gotta, J., Reschke, P., Martin, S. S., Mahmoudi, S., Bernatz, S., Eichler, K., D’Angelo, T., Chernyak, V., et al. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.111283 · Cited by 5 · see citing works
Laugerette, A., Baum, T. H., Gersing, A. S., Schwaiger, B. J., Brown, K., Frerking, L. C., Shapira, N., Pfeiffer, D., Rummeny, E. J., Proksa, R., et al. (2020) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abab6b · Cited by 5 · see citing works
Self-citationSlot‐scan dual‐energy bone densitometry using motorized X‐ray systems
Zhao, C., Herbst, M., Weber, T., Luckner, C., Vogt, S. K., Ritschl, L., Kappler, S. G., Siewerdsen, J. H., & Zbijewski, W. B. (2021) · Medical Physics · doi:10.1002/mp.15272 · Cited by 4 · see citing works
Hayashi, H., Nishigami, R., Asahara, T., Kimoto, N., Kobayashi, D., Mitani, M., Akagi, N., Higaki, F., & Iguchi, T. (2026) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2026.112768 · Cited by 3 · see citing works
Lumbar muscle involvement in the occurrence of osteoporotic vertebral fracture
Lambeaux, C., Lapègue, F., Fayolle, H., Degboé, Y., Chiavassa-Gandois, H., Basselerie, H., Goumarre, C., Bilger, R., Sans, N., & Faruch, M. (2024) · Research in Diagnostic and Interventional Imaging · doi:10.1016/j.redii.2023.100037 · Cited by 2 · see citing works
CT Scout Scans with Deep Learning for Ultra-low Dose Attenuation Correction in PET
Muller, F. M., Daube-Witherspoon, M. E., Liu, L. P., Parma, M. J., Perkins, A. E., Li, E., Pantel, A. R., Noël, P. B., Vanhove, C., Vandenberghe, S., et al. (2024) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nss/mic/rtsd57108.2024.10658404 · Cited by 1 · see citing works
Self-citationDifferent Models of Dual-Energy Bone DXA Scanners: A Comparative Study
Petraikin, A. V., Akhmad, E. S., Семенов, Д. С., Artyukova, Z. R., Kudryavtsev, N. D., Петряйкин, Ф. А., & Низовцова, Л. А. (2022) · Traumatology and Orthopedics of Russia · doi:10.17816/2311-2905-1731 · Cited by 1 · see citing works
Yu, J., Song, Y., Yang, A., Zhang, X., & Li, L. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23787
Visceral adipose tissue volume effect in Crohn's disease using reduced exposure CT enterography
Hunter, S. A., Baker, M. E., Ream, J., Sweet, D. E., Austin, N. A., Remer, E. M., Primak, A. N., Bullen, J. A., Obuchowski, N. A., Karim, W., et al. (2023) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.14235
Kuang, J., & Tang, Z. (2025) · Radiology Science · doi:10.15212/radsci-2024-0003
Patzer, T. S., Schwartz, F. R., Panta, R. K., Farhadi, F., Liu, F., Bouxsein, M., Palmer, W. E., Guermazi, A., Jóhannesdóttir, F., & Jarraya, M. (2026) · Skeletal Radiology · doi:10.1007/s00256-026-05218-y
Liu, Z., & Ge, H. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1923817
- Authors
- Laugerette, A., Schwaiger, B. J., Brown, K., Frerking, L. C., Kopp, F. K., Mei, K., Sellerer, T., Kirschke, J., Baum, T., Gersing, A. S., Pfeiffer, D., Fingerle, A. A., Rummeny, E. J., Proksa, R., Noël, P. B., & Pfeiffer, F.
- Affiliations
- TUM Klinikum (DE)
- Philips (Germany) (DE)
- Technical University of Munich (DE)
- Corresponding author
- Noël, Peter B.
- ORCID
- Venue
- European Radiology
- Published
- 2019-02-13
- Volume
- 29
- Issue
- 9
- Pages
- 4624-4634
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2911756823
- Cited by
- 29
- References
- 33
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 2 · 2022: 1 · 2021: 6 · 2020: 6 · 2019: 1
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
- Funders
- BMBF (13GW0072C)
- DFG (GRK2274)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Keywords
- spectral CT, dual-layer spectral CT, spine, osteoporosis screening, opportunistic screening, tube current, soft tissue segmentation, vertebral segmentation, precision and accuracy, female patients
- MeSH terms
- Adult, Age Factors, Aged, Algorithms, Feasibility Studies, Female, Humans, Image Processing, Computer-Assisted, Middle Aged, Osteoporosis, Spine, Tomography, X-Ray Computed, Reproducibility of Results, Bone Density, Phantoms, Imaging, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review