The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology
Open accessAbstract
The diagnostic yield of transesophageal and transthoracic echocardiography for identifying a cardiac source of embolism was compared in 79 patients presenting with unexplained stroke or transient ischemic attack. There were 35 men and 44 women with a mean age of 59 years (range 17 to 84); 52% had clinical cardiac disease. Both transthoracic and transesophageal echocardiograms were performed using Doppler color flow and contrast imaging. Transesophageal echocardiography identified a potential cardiac source of embolism in 57% of the overall study group compared with only 15% by transthoracic echocardiography (p less than 0.0005). Compared with transthoracic echocardiography, transesophageal echocardiography more frequently identified atrial septal aneurysm associated with a patent foramen ovale (9 versus 1 of 79 patients, p less than 0.005), left atrial thrombus or tumor (6 versus 0 of 79 patients, p less than 0.05) and left atrial spontaneous contrast (13 versus 0 of 79 patients, p less than 0.0005). All cases of left atrial thrombus or spontaneous contrast were identified in patients with clinically identified cardiac disease. In the 38 patients with no cardiac disease, transesophageal echocardiography identified isolated atrial septal aneurysm and atrial septal aneurysm with a patent foramen ovale more frequently than transthoracic echocardiography (8 versus 2 of 38 patients, p less than 0.05). The two techniques had a similar rate of identifying apical thrombus and mitral valve prolapse. Overall, transesophageal echocardiography identified abnormalities in 39% of patients with no cardiac disease versus 19% for transthoracic echocardiography (p less than 0.005). Thus, transesophageal echocardiography identifies potential cardiac sources of embolism in the majority of patients presenting with unexplained stroke.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hagen, P. T., SCHOLZ, D. G., & Edwards, W. D. (1984) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60336-x · Cited by 2,528
Prevalence of Patent Foramen Ovale in Patients with Stroke
Lechat, P., Mas, J. L., Lascault, G., Loron, P., Theard, M., Klimczac, M., Drobinski, G., Thomas, D., & Grosgogeat, Y. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805053181802 · Cited by 1,657
Cardiogenic brain embolism. The second report of the Cerebral Embolism Task Force.
ASINGER, R. W., Dyken, M. L., Fisher, M., Hart, R., & Sherman, D. G. (1989) · PubMed · Cited by 548
Daniel, W. G., Nellessen, U., Schröder, E., Nonnast-Daniel, B., Bednarski, P., Nikutta, P., & Lichtlen, P. R. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90283-5 · Cited by 498
Transesophageal two-dimensional echocardiography for the detection of left atrial appendage thrombus
Aschenberg, W., Schlüter, M., Kremer, P., Schröder, E., Siglow, V., & Bleifeld, W. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80275-3 · Cited by 441
Cardiogenic Brain Embolism: The Second Report of the Cerebral Embolism Task Force
(1989) · Archives of Neurology · doi:10.1001/archneur.1989.00520430021013 · Cited by 404
Further Evidence Relating Mitral-Valve Prolapse to Cerebral Ischemic Events
Barnett, H. J. M., Boughner, D. R., Taylor, D. W., Cooper, P. E., Kostuk, W. J., & Nichol, P. M. (1980) · New England Journal of Medicine · doi:10.1056/nejm198001173020303 · Cited by 346
Levine, R. A., Stathogiannis, E., Newell, J. B., Harrigan, P., & Weyman, A. E. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)90059-6 · Cited by 315
Castello, R., Pearson, A. C., & Labovitz, A. J. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90330-4 · Cited by 202
Self-citationShrestha, N. K., Moreno, F. L., Narciso, F. V., Torres, L., & Calleja, H. B. (1983) · Circulation · doi:10.1161/01.cir.67.2.341 · Cited by 187
Two-Dimensional Echocardiography in Patients with Focal Cerebral Ischemia
LOVETT, J. L., SANDOK, B. A., GIULIANI, E. R., & NASSER, F. N. (1981) · Annals of Internal Medicine · doi:10.7326/0003-4819-95-1-1 · Cited by 118
Dynamic intracavitary left atrial echoes in mitral stenosis
Iliceto, S., Gf, A., Sorino, M., Biasco, G., & RIZZON, P. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90267-x · Cited by 72
Wald, E. R. (1962) · The Lancet · doi:10.1016/s0140-6736(62)90460-9 · Cited by 25
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,158
Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies
Overell, J. R., Bone, I., & Lees, K. R. (2000) · Neurology · doi:10.1212/wnl.55.8.1172 · Cited by 936
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Metadata
- Authors
- Pearson, A. C., Labovitz, A. J., Tatineni, S., & Gomez, C. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 17
- Issue
- 1
- Pages
- 66-72
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2056270834
- Cited by
- 570
- References
- 13
- FWCI
- 48.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.