CoChat

Ambulatory blood pressure monitoring (ABPM) in the normal menstrual cycle and in women using oral contraceptivesComparison with conventional blood pressure measurement

Open access
WILLIAMSON, P, BUDDLE, M, BROWN, M, WHITWORTH, J · 1996 · American Journal of Hypertension
Cited by 28

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This study was undertaken to determine if blood pressures (BP) assessed by routine sphygmomanometry and 24 h ambulatory monitoring (ABPM) alter throughout the normal menstrual cycle or in the cycle of women using oral contraceptive pills (OCP), and the interrelationships between urinary sodium (Na) and potassium (K) excretion and ABPM throughout the menstrual cycle. Eleven women with a normal ovulatory cycle (ovulatory) and ten age-matched women taking an oral contraceptive pill (OCP) were studied three times in random order during their menstrual cycle, within days 1 to 5, 13 to 16, and 25 to 28. Twenty-four hour urine Na, K, and creatinine (Cr) excretion and serum Na, K, Cr, cortisol, estradiol, progesterone and plasma renin, angiotensinogen, and aldosterone concentrations were measured. BP was measured by a mercury sphygmomanometer and by 24 h BP (Accutracker II). On days 1 to 5, daytime systolic BP was higher in OCP [mean: 123 mm Hg, 95% confidence interval: 117, 128] than ovulatory women [114 mm Hg (109, 118); P = .011] though daytime diastolic BPs were similar [OCP: 71 (68, 75), ovulatory: 69 (66, 72)]. This difference in daytime systolic BP between groups was also apparent at both of the other stages of the menstrual cycle. Nighttime systolic BPs were significantly higher in OCP users on days 13 to 16 (P < .05) and days 25 to 28 (P < .01). In women taking OCPs, daytime ABPM for days 1 to 5 were higher than their office readings by 15 (7,23)/11 (7,15) mm Hg (P = .001), whereas office and ABPM readings were similar in ovulatory women. This pattern was evident at all three stages. There was no significant change in BP throughout the menstrual cycle within either group, and no correlation between urine Na or K and BP. Systolic BPs are higher throughout the menstrual cycle in women who take OCPs than in ovulatory women but this difference is only detected when ambulatory blood pressure is assessed. Blood pressure does not change subsequently in either ovulatory or OCP-taking women throughout the menstrual cycle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0895-7061(96)00150-1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 28

Metadata

Authors
WILLIAMSON, P., BUDDLE, M., BROWN, M., & WHITWORTH, J.
Venue
American Journal of Hypertension
Published
1996-10
Volume
9
Issue
10
Pages
953-958
ISSN
0895-7061 (ISSN-L)
OpenAlex
W2021866966
Cited by
28
References
1
FWCI
0.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory blood pressure monitoring (ABPM) in the normal menstrual cycle and in women using oral contraceptivesComparison with conventional blood pressure measurement. https://app.cochat.ai/papers/10.1016/0895-7061(96)00150-1
The paper
WILLIAMSON, P., BUDDLE, M., BROWN, M., & WHITWORTH, J. (1996). Ambulatory blood pressure monitoring (ABPM) in the normal menstrual cycle and in women using oral contraceptivesComparison with conventional blood pressure measurement. American Journal of Hypertension. https://doi.org/10.1016/0895-7061(96)00150-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.