The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Open accessAbstract
We review the principles of elastography and some of its accomplishments to date in the area of breast imaging in vivo. We present a literature review of a variety of methods for the estimation of tissue elasticity that have been reported in the literature in the past 15 years, and of data on the elastic properties of soft tissues. This is followed by a description of elastography and its relationship to the theory of elasticity. The principles underlying the elastography imaging technique, and methods for time delay estimations and their tradeoffs are discussed. We then present results of computer simulations, phantom and tissue studies in vitro, and some breast imaging studies in vivo. After a discussion of the origin and appearance of some important elastographic artifacts, we conclude with some general observations and conclusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationStatistics of Speckle in Ultrasound B-Scans
Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1983.31404 · Cited by 1,398
The Fourier transform and its applications
Hautus, M. L. J. (1980) · European Journal of Operational Research · doi:10.1016/0377-2217(80)90120-4 · Cited by 1,144
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
McDonough, R. N., & WHALEN, A. D. (1971) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,041
Application des potentiels : à l'etude de l'equilibre et du mouvement des solides élastiques
Boussinesq, J., & Caquot, M. A. (1885) · Medical Entomology and Zoology · Cited by 916
(1971) · Elsevier eBooks · doi:10.1016/c2013-0-07634-7 · Cited by 894
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Cited by
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Self-citationElastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationTanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Self-citation
Metadata
- Authors
- Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N.
- Venue
- European Journal of Ultrasound
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 3
- Issue
- 1
- Pages
- 49-70
- ISSN
- 0929-8266 (ISSN-L)
- OpenAlex
- W2025257705
- Cited by
- 287
- References
- 43
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo. https://app.cochat.ai/papers/10.1016/0929-8266(95)00134-4
- The paper
- Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996). Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo. European Journal of Ultrasound. https://doi.org/10.1016/0929-8266(95)00134-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.