Tandem Mass Spectrometry of Small, Multiply Charged Oligonucleotides
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Multiply charged anions derived from electrospray ionization of the sodium salts of various small oligonucleotides (n = 4-8) have been subjected to tandem mass spectrometry (MS/MS) in a quadrupole ion trap. All ions were observed to dissociate with high efficiencies even under conditions not ordinarily conducive for the observance of high MS/MS efficiency. Large fractions of the total product ion signal could be attributed to single-cleavage reactions with the parent ion charge shared among the two product ions in various combinations. In every case, the most facile reaction was observed to be the loss of the adenine anion. This reaction was then observed to be followed by cleavage of the 3' C-O bond of phosphodiester linkage of the sugar from which the adenine had been lost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Recent improvements in and analytical applications of advanced ion trap technology
Stafford, G. C., Kelley, P. E., Syka, J. E. P., Reynolds, W. E., & Todd, J. F. J. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)80077-4 · Cited by 561
Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometry
Louris, J. N., Cooks, R. G., Syka, J. E. P., Kelley, P. E., Stafford, G. C., & Todd, J. F. J. (1987) · Analytical Chemistry · doi:10.1021/ac00140a021 · Cited by 500
Multiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
Electrospray ionization combined with ion trap mass spectrometry
Van Berkel, G. J., Glish, G. L., & McLuckey, S. A. (1990) · Analytical Chemistry · doi:10.1021/ac00212a016 · Cited by 246
Self-citationElectrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
High resolution on a quadrupole ion trap mass spectrometer
Schwartz, J. C., Syka, J. E. P., & Jardine, I. (1991) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(91)80044-8 · Cited by 180
McLuckey, S. A., Glish, G. L., Asano, K. G., & Grant, B. C. (1988) · Analytical Chemistry · doi:10.1021/ac00171a012 · Cited by 175
Self-citationFast atom bombardment combined with tandem mass spectrometry for the determination of nucleosides
Crow, F. W., Tomer, K. B., Gross, M. L., McCloskey, J. A., & Bergstrom, D. E. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90412-3 · Cited by 136
Extending the mass range of the quadrupole ion trap using axial modulation
KAISER, R. E., Louris, J. N., Amy, J. W., Cooks, R. G., & Hunt, D. F. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290030706 · Cited by 131
Selective ion isolation/rejection over a broad mass range in the quadrupole ion trap
McLuckey, S. A., Goeringer, D. E., & Glish, G. L. (1991) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(91)80056-d · Cited by 120
Self-citationHenry, K. D., & McLafferty, F. W. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210250912 · Cited by 115
Coupling of an atmospheric-samling ion source with an ion-trap mass spectrometer
McLuckey, S. A., Glish, G. L., & Asano, K. G. (1989) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)84591-2 · Cited by 106
Self-citationIon spray liquid chromatography/ion trap mass spectrometry determination of biomolecules
McLuckey, S. A., Berkel, G. J. V., Glish, G. L., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00004a015 · Cited by 105
Self-citationMultiple stages of mass spectrometry in a quadrupole ion trap mass spectrometer: prerequisites
McLuckey, S. A., Glish, G. L., & Berkel, G. J. V. (1991) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(91)85020-m · Cited by 84
Self-citationMass range extension in a quadrupole ion‐trap mass spectrometer
KAISER, R. E., Cooks, R. G., Moss, J., & Hemberger, P. H. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290030213 · Cited by 62
McNeal, C. J., Narang, S. A., Macfarlane, R. D., Hsiung, H. M., & Brousseau, R. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.2.735 · Cited by 46
Cited by
Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Katoh, T., Sakaguchi, Y., Miyauchi, K., Suzuki, T., Kashiwabara, S.-I., Baba, T., & Suzuki, T. (2009) · Genes & Development · doi:10.1101/gad.1761509 · Cited by 440
Schnier, P. D., Price, W. D., Jockusch, R. A., & Williams, E. R. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9609157 · Cited by 394
Metadata
- Authors
- Mcluckey, S. A., Van Berkel, G. J., & Glish, G. L.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1992-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 60-70
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2082300861
- Cited by
- 551
- References
- 24
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.