An examination of the micromechanics of failure of bone and antler by acoustic emission tests and Laser Scanning Confocal Microscopy
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Bone fails as a result of damage accumulation in the form of microcracks. Antler is in essence less mineralized bone, but is much tougher than ordinary bone. Failure through damage accumulation also happens in antler, so it is clear that antler's microcracks must be pervasive and that natural selection has produced mechanisms for this material which make it more damage-tolerant. We have examined the development of damage in bone and antler by cyclic loading in three-point bending. We have also conducted acoustic emission studies on these two materials during monotonic tensile loading, and used Laser Scanning Confocal Microscopy (LSCM) to observe microcracks in samples which had been mechanically damaged. We found that diffuse microcracking coincides with the appearance of a macroscopic region of 'yield' in the stress/strain curve of bone and antler; it is related to the local stress (or strain) field that microcracks interact with the structure (particularly in antler). Both acoustic emissions studies and LSCM observations indicated that antler may possess additional modes of stable micromechanical failure compared with ordinary bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giloh, H., & Sedat, J. W. (1982) · Science · doi:10.1126/science.7112126 · Cited by 838
SHIINA, S., AOYAMA, H., SHIRATORI, Y., MUTOH, H., KURITA, M., OTA, S., TERANO, A., & SUGIMOTO, T. (1990) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199006000-00006 · Cited by 654
(1960) · Henry Ford Hospital medical bulletin · Cited by 397
(2020) · Encyclopedia of Continuum Mechanics · doi:10.1007/978-3-662-55771-6_300001 · Cited by 350
Mechanical properties of bone tissues with greatly differing functions
Currey, J. D. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90073-3 · Cited by 291
Self-citationBone creep-fatigue damage accumulation
Caler, W. E., & Carter, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90013-4 · Cited by 263
A cumulative damage model for bone fracture
Carter, D. R., & Caler, W. E. (1985) · Journal of Orthopaedic Research · doi:10.1002/jor.1100030110 · Cited by 260
The extent of microcracking and the morphology of microcracks in damaged bone
Zioupos, P., & Currey, J. D. (1994) · Journal of Materials Science · doi:10.1007/bf00351420 · Cited by 241
Self-citationPhysical characteristics affecting the tensile failure properties of compact bone
Currey, J. D. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90030-7 · Cited by 225
Self-citationFluorophores for Confocal Microscopy: Photophysics and Photochemistry
Tsien, R. Y., Ernst, L., & Waggoner, A. (2006) · Handbook Of Biological Confocal Microscopy · doi:10.1007/978-0-387-45524-2_16 · Cited by 201
Perspectives in Biomedical Engineering
(1973) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-01604-4 · Cited by 136
Composites with high work of fracture
Gordon, J. E., & Jeronimidis, G. (1980) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1980.0063 · Cited by 115
Voyiadjis, G. Z. (2005) · Springer eBooks · doi:10.1007/978-1-4020-3286-8_60 · Cited by 106
Anelasticity in Bone and Echinoderm Skeletons
Currey, J. D. (1965) · Journal of Experimental Biology · doi:10.1242/jeb.43.2.279 · Cited by 73
Self-citationPermanent deformation of compact bone monitored by acoustic emission
Wright, T. M., Vosburgh, F., & Burstein, A. H. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90058-0 · Cited by 71
Young's modulus of compact bone
Bonfield, W., & Datta, P. K. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90053-0 · Cited by 58
Currey, J. D. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90207-8 · Cited by 55
Self-citationCurrey, J. D., & Brear, K. (1974) · Calcified Tissue International · doi:10.1007/bf02059054 · Cited by 54
Self-citationSimple constitutive model for a cortical bone
Krajcinovic, D., Trafimow, J., & Šumarac, D. M. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90057-1 · Cited by 43
Failure Characteristics of Bone and Bone Tissue
Burstein, A. H., Reilly, D. T., & Frankel, V. H. (1973) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-01604-4_21 · Cited by 43
Creep fracture in bones with different stiffnesses
Mauch, M., Currey, J. D., & Sedman, A. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90241-r · Cited by 36
Self-citationAnalysis of the effect of using two different strain rates on the acoustic emission in bone
Fischer, R. A., Arms, S. W., Pope, M. H., & Seligson, D. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90142-9 · Cited by 28
Microcracking in dog bone under load: A biomechanical study of bone visco-elasticity
Jonsson, U., & Eriksson, K. (1984) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678408992391 · Cited by 25
Anelastic deformation and the friction stress of bone
Bonfield, W., & O'Connor, P. D. T. (1978) · Journal of Materials Science · doi:10.1007/bf00739292 · Cited by 23
Material Reaction of Diaphyseal Bone Under Torsion:An Experimental Study on Dogs
Netz, P., Eriksson, K., & Strömbkrg, L. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990790 · Cited by 20
Ultimate Failure of Diaphyseal Bone:An Experimental Study on Dogs
Netz, P., Eriksson, K., & Stromberg, L. R. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990846 · Cited by 12
Acoustic emission in human bone tissue subjected to longitudinal extension
Knēts, I., Krauya, U. �., & Vilks, Y. K. (1976) · Mechanics of Composite Materials · doi:10.1007/bf00856790 · Cited by 12
Cited by
Biological materials: Functional adaptations and bioinspired designs
Chen, P.-Y., McKittrick, J., & Meyers, M. A. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.03.001 · Cited by 766
“The low yield strength in the longitudinal direction allows crack-tip plastic zones to form at lower stresses than in human bone [65,236], which contributes to the large inelastic deformation and thereby to its intrinsic toughness.”
BackgroundStructure and mechanics of interfaces in biological materials
Barthelat, F., Yin, Z., & Buehler, M. J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.7 · Cited by 765
On the Mechanistic Origins of Toughness in Bone
Launey, M. E., Buehler, M. J., & Ritchie, R. O. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070909-104427 · Cited by 741
Changes in the Stiffness, Strength, and Toughness of Human Cortical Bone With Age
Zioupos, P., & Currey, J. D. (1998) · Bone · doi:10.1016/s8756-3282(97)00228-7 · Cited by 643
Self-citationModelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
Metadata
- Authors
- Zioupos, P., Currey, J. D., & Sedman, A. J.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1994-05-01
- Volume
- 16
- Issue
- 3
- Pages
- 203-212
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2016205361
- Cited by
- 162
- References
- 27
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.