The DOI matches its Crossref record.
Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Abstract
The three-dimensional microstructure of cancellous bone seems to be one of the key factors in the prediction of mechanical bone properties like bone strength or bone stiffness. In this paper trabecular bone structure was assessed nondestructively by means of high-resolution computed tomography (CT) with a spatial resolution of 250 microns. Mineralized bone was separated from bone marrow and muscle tissue with the help of a three-dimensional segmentation algorithm based on the analysis of directional derivatives. From the three-dimensional stack of CT slices a subvolume comparable in size (3.6 x 3.4 x 3.4 mm3) to standard histologic bone sections was selected. We refer to this subvolume as non-invasive bone biopsy. A new automated mesh generator was developed to create a three-dimensional finite element model of the non-invasive bone biopsy. Four-noded tetrahedron solid elements were used to guarantee a smooth surface representation. The aim of the presented work was to demonstrate the potential of high-resolution CT imaging in the prediction of the anisotropic material properties of cancellous bone. Preliminary results of the 3D finite element stress analysis are very promising. The predicted value of the apparent Young's modulus (564 MPa) is within the range reported for uniaxial compression testings of cancellous bone specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
Self-citationA microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Self-citationMüller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Self-citationMacdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Metadata
- Authors
- Müller, R., & Rüegsegger, P.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1995-03-01
- Volume
- 17
- Issue
- 2
- Pages
- 126-133
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2009222457
- Cited by
- 240
- References
- 0
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures. https://app.cochat.ai/papers/10.1016/1350-4533(95)91884-j
- The paper
- Müller, R., & Rüegsegger, P. (1995). Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures. Medical Engineering & Physics. https://doi.org/10.1016/1350-4533(95)91884-j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.