Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The three-dimensional microstructure of cancellous bone seems to be one of the key factors in the prediction of mechanical bone properties like bone strength or bone stiffness. In this paper trabecular bone structure was assessed nondestructively by means of high-resolution computed tomography (CT) with a spatial resolution of 250 microns. Mineralized bone was separated from bone marrow and muscle tissue with the help of a three-dimensional segmentation algorithm based on the analysis of directional derivatives. From the three-dimensional stack of CT slices a subvolume comparable in size (3.6 x 3.4 x 3.4 mm3) to standard histologic bone sections was selected. We refer to this subvolume as non-invasive bone biopsy. A new automated mesh generator was developed to create a three-dimensional finite element model of the non-invasive bone biopsy. Four-noded tetrahedron solid elements were used to guarantee a smooth surface representation. The aim of the presented work was to demonstrate the potential of high-resolution CT imaging in the prediction of the anisotropic material properties of cancellous bone. Preliminary results of the 3D finite element stress analysis are very promising. The predicted value of the apparent Young's modulus (564 MPa) is within the range reported for uniaxial compression testings of cancellous bone specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Kleerekoper, M., Villanueva, A. R., Stanciu, J., Rao, D. S., & Parfitt, A. M. (1985) · Calcified Tissue International · doi:10.1007/bf02554913 · Cited by 695
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603
Cited by
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
Self-citationA microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Self-citationMüller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Self-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Burghardt, A. J., Issever, A. S., Schwartz, A. V., Davis, K. A., Masharani, U., Majumdar, S., & Link, T. M. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0226 · Cited by 460
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
Increased cortical porosity in type 2 diabetic postmenopausal women with fragility fractures
Patsch, J. M., Burghardt, A. J., Yap, S. P., Baum, T., Schwartz, A. V., Joseph, G. B., & Link, T. M. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1763 · Cited by 436
Macdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
Whittier, D. E., Boyd, S. K., Burghardt, A. J., Paccou, J., Ghasem-Zadeh, A., Chapurlat, R., Engelke, K., & Bouxsein, M. L. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05438-5 · Cited by 370
Burghardt, A. J., Kazakia, G. J., Ramachandran, S., Link, T. M., & Majumdar, S. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091104 · Cited by 336
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques
Ulrich, D., van Rietbergen, B., Weinans, H., & Rüegsegger, P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00118-3 · Cited by 279
Self-citationFinite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Burghardt, A. J., Kazakia, G. J., Sode, M., de Papp, A. E., Link, T. M., & Majumdar, S. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.157 · Cited by 239
High-Resolution Imaging Techniques for the Assessment of Osteoporosis
Krug, R., Burghardt, A. J., Majumdar, S., & Link, T. M. (2010) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2010.02.015 · Cited by 234
“15).(110,111) For HR-pQCT this technique has been validated against both higher resolution models (mCT) as well as empirical measures of strength.”
Biomechanical 3-D finite element modeling of the human breast using MRI data
Samani, A., Bishop, J., Yaffe, M. J., & Plewes, D. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921476 · Cited by 217
Biological materials: A materials science approach
Meyers, M. A., Chen, P.-Y., Lopez, M. I., Seki, Y., & Lin, A. Y. M. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.08.005 · Cited by 204
Clinical Imaging of Bone Microarchitecture with HR-pQCT
Nishiyama, K. K., & Shane, E. (2013) · Current Osteoporosis Reports · doi:10.1007/s11914-013-0142-7 · Cited by 187
Shefelbine, S. J., Simon, U., Claes, L., Gold, A., Gabet, Y., Bab, I., Müller, R., & Augat, P. (2005) · Bone · doi:10.1016/j.bone.2004.11.007 · Cited by 179
“Previous studies have used finite element models derived from CT images to determine the mechanical properties of whole bones [8,12], fractured bones [33], trabecular bone [21,36], and osteoporotic bone [22].”
BackgroundSelf-citationMulti-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 177
“Finally, micro finite element (micro FE) analysis was used for computing the elastic and yield properties of trabecular bone based on 3D reconstructions (Hollister et al. 1994; Muller and Ruegsegger 1995; van Rietbergen et al. 1995; Ladd and Kinney 1998; Niebur et al. 2000, 2002; van Rietbergen 2001).”
MethodTrabecular bone fracture healing simulation with finite element analysis and fuzzy logic
Shefelbine, S. J., Augat, P., Claes, L., & Simon, U. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.10.019 · Cited by 163
Nishiyama, K. K., Macdonald, H. M., Moore, S. A., Fung, T., Boyd, S. K., & McKay, H. A. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.552 · Cited by 122
Ural, A., & Vashishth, D. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768377 · Cited by 62
Pauchard, Y., Mattmann, C., Kuhn, A., Gasser, J. A., & Boyd, S. K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.036 · Cited by 12
“Furthermore, the 3D image can be analyzed by micro-finite element ðmFEÞ techniques to determine mechanical properties such as stiffness or strength (Müller and Rüegsegger, 1995; van Rietbergen et al., 1995).”
Method
Metadata
- Authors
- Müller, R., & Rüegsegger, P.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1995-03-01
- Volume
- 17
- Issue
- 2
- Pages
- 126-133
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2009222457
- Cited by
- 240
- References
- 28
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.