Relations of mechanical properties to density and CT numbers in human bone
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Mechanical properties of cortical and cancellous bone from eight human subjects were determined using an ultrasonic transmission technique. Raw computerized tomography (CT) values obtained from scans of the bones in water were corrected to Hounsfield units. The correlations between CT numbers and mechanical property estimated from cortical bone were found to be low (r2 < 0.2), while these relationships for cancellous bone were found to be higher (r2 > 0.6). These results suggest that CT values may be useful in predicting mechanical properties only for cancellous bone. Poor correlations were found between modulus in the radial or circumferential direction and modulus in the superior-inferior direction for cortical bone, whereas good correlations were found between modulus in the anterior-posterior direction or medial-lateral direction and modulus in the S-I direction for cancellous bone. These results indicate that modulus in the radial or circumferential direction could not be predicted from modulus in the S-I direction for cortical bone, but could be predicted for cancellous bone. The predictive capabilities of linear and power models evaluated for cancellous bone alone were approximately equal. However, the power function gives a better fit of data at the low and high density values. The specific relationships, depending on the types of bone, that predict elastic modulus from density and CT numbers were suggested for human cortical and cancellous bone. These specific correlations may help a number of researchers develop more accurate models; however, these hypotheses should be proven by further study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Self-citationThe mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
The Mechanical Adaptations of Bones
Currey, J. D. (1984) · Princeton University Press eBooks · doi:10.1515/9781400853724 · Cited by 896
The effect of porosity and mineral content on the Young's modulus of elasticity of compact bone
Currey, J. D. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90006-1 · Cited by 799
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationThe mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Stiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Self-citationBioactive glass in tissue engineering
Rahaman, M. N., Day, D. E., Sonny Bal, B., Fu, Q., Jung, S. B., Bonewald, L. F., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.016 · Cited by 1,794
Bioactive glass scaffolds for bone tissue engineering: state of the art and future perspectives
Fu, Q., Saiz, E., Rahaman, M. N., & Tomsia, A. P. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2011.04.022 · Cited by 703
Aubry, J.-F., Tanter, M., Pernot, M., Thomas, J.-L., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1529663 · Cited by 581
Bio-CAD modeling and its applications in computer-aided tissue engineering
Sun, W., Starly, B., Nam, J., & Darling, A. (2005) · Computer-Aided Design · doi:10.1016/j.cad.2005.02.002 · Cited by 386
Fu, Q., Saiz, E., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.030 · Cited by 366
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“Their relation has been extensively studied in the past [93,97,63,88,104,133,25,10].”
BackgroundThe dependence of transversely isotropic elasticity of human femoral cortical bone on porosity
Neil Dong, X., & Edward Guo, X. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.011 · Cited by 302
Taddei, F., Pancanti, A., & Viceconti, M. (2004) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00138-3 · Cited by 274
Peng, L., Bai, J., Zeng, X., & Zhou, Y. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.06.003 · Cited by 262
Bioinspired Strong and Highly Porous Glass Scaffolds
Fu, Q., Saiz, E., & Tomsia, A. P. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002030 · Cited by 252
Sun, W., Starly, B., Darling, A., & Gomez, C. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030109 · Cited by 223
Material properties assignment to finite element models of bone structures: a new method
Zannoni, C., Mantovani, R., & Viceconti, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00081-2 · Cited by 210
“In the particular case of living tissues, however, the relationship between CT numbers, Hounsfield Units (HU), and tissue density is monotonic and, as a first approximation, linear [3–5].”
BackgroundDental implant induced bone remodeling and associated algorithms
Lin, D., Li, Q., Li, W., & Swain, M. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.11.007 · Cited by 194
Jaecques, S. V. N., Van Oosterwyck, H., Muraru, L., Van Cleynenbreugel, T., De Smet, E., Wevers, M., Naert, I., & Vander Sloten, J. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00516-7 · Cited by 186
“As to the latter, it has been shown experimentally that the Hounsfield values (grey values), which are a measure for the attenuation coefficient of the material (relative to the attenuation coefficient of water), can be used to predict the Young’s modulus of trabecular bone [17,18].”
MethodSurface morphology optimization for osseointegration of coated implants
Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.077 · Cited by 105
The investigation of bone fracture healing under intramembranous and endochondral ossification
Ghimire, S., Miramini, S., Edwards, G., Rotne, R., Xu, J., Ebeling, P., & Zhang, L. (2021) · Bone Reports · doi:10.1016/j.bonr.2020.100740 · Cited by 83
Elastic and physicochemical relationships within cortical bone
Kohles, S. S., & Martinez, D. A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000315)49:4<479::aid-jbm6>3.0.co;2-6 · Cited by 29
Metadata
- Authors
- Rho, J. Y., Hobatho, M. C., & Ashman, R. B.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1995-07-01
- Volume
- 17
- Issue
- 5
- Pages
- 347-355
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2046354206
- Cited by
- 822
- References
- 29
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.