Circumventing Photodamage in Live-Cell Microscopy
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Fluorescence microscopy has become an essential tool in cell biology. This technique allows researchers to visualize the dynamics of tissue, cells, individual organelles and macromolecular assemblies inside the cell. Unfortunately, fluorescence microscopy is not completely ‘non-invasive’ as the high-intensity excitation light required for excitation of fluorophores is inherently toxic for live cells. Physiological changes induced by excessive illumination can lead to artifacts and abnormal responses. In this chapter we review major factors that contribute to phototoxicity and discuss practical solutions for circumventing photodamage. These solutions include the proper choice of image acquisition parameters, optimization of filter sets, hardware synchronization, and the use of intelligent illumination to avoid unnecessary light exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guns, Germs, and Steel: The Fates of Human Societies.
Hardin, G., & Diamond, J. (1997) · Population and Development Review · doi:10.2307/2137390 · Cited by 4,979
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355 · cited 4×
“Most notable hardware-based approaches to decreasing phototoxicity include Selective Plane Illumination Microscopy (SPIM) (Huisken et al., 2004), its more recent variant termed Bessel-beam Plane Illumination (Planchon et al.”
InfluentialFluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375 · cited 1×
“Absorption spectra of fluorescent proteins are usually wide (Chudakov et al., 2010).”
Rapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination
Planchon, T. A., Gao, L., Milkie, D. E., Davidson, M. W., Galbraith, J. A., Galbraith, C. G., & Betzig, E. (2011) · Nature Methods · doi:10.1038/nmeth.1586 · Cited by 1,112 · cited 3×
“, 2004), its more recent variant termed Bessel-beam Plane Illumination (Planchon et al., 2011), and Controlled Light Exposure Microscopy (CLEM) (Hoebe et al.”
Improving the photostability of bright monomeric orange and red fluorescent proteins
Shaner, N. C., Lin, M. Z., McKeown, M. R., Steinbach, P. A., Hazelwood, K. L., Davidson, M. W., & Tsien, R. Y. (2008) · Nature Methods · doi:10.1038/nmeth.1209 · Cited by 1,009
A Mechanism for Nuclear Positioning in Fission Yeast Based on Microtubule Pushing
Tran, P. T., Marsh, L., Doye, V., Inoué, S., & Chang, F. (2001) · The Journal of Cell Biology · doi:10.1083/jcb.153.2.397 · Cited by 479 · cited 2×
“This approach has been proven quite beneficial when the objects are morphologically distinct (Chang et al., 1999; Tran et al., 2001) or when morphologically-similar objects exhibit distinctly different behavior (Magidson et al.”
Hoebe, R. A., Van Oven, C. H., Gadella, T. W. J., Dhonukshe, P. B., Van Noorden, C. J. F., & Manders, E. M. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1278 · Cited by 435 · cited 5×
“Most notable hardware-based approaches to decreasing phototoxicity include Selective Plane Illumination Microscopy (SPIM) (Huisken et al., 2004), its more recent variant termed Bessel-beam Plane Illumination (Planchon et al., 2011), and Controlled Light Exposure Microscopy (CLEM) (Hoebe et al., 2007).”
InfluentialKhodjakov, A., & Rieder, C. L. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.146.3.585 · Cited by 350 · cited 1×
“The percentage of cells that undergo cell cycle reversion is greater if the population is stressed by anti-microtubule drugs (Khodjakov and Rieder, 1999).”
Self-citationKhodjakov, A., & Rieder, C. L. (2001) · The Journal of Cell Biology · doi:10.1083/jcb.153.1.237 · Cited by 345 · cited 2×
“For example, physical removal of the centrosome from mammalian cells has been reported to result in a cell-cycle arrest during G1 phase of the cell cycle (Hinchcliffe et al., 2001; Khodjakov and Rieder, 2001).”
Self-citationRequirement of a Centrosomal Activity for Cell Cycle Progression Through G 1 into S Phase
Hinchcliffe, E. H., Miller, F. J., Cham, M., Khodjakov, A., & Sluder, G. (2001) · Science · doi:10.1126/science.1056866 · Cited by 339 · cited 2×
“For example, physical removal of the centrosome from mammalian cells has been reported to result in a cell-cycle arrest during G1 phase of the cell cycle (Hinchcliffe et al., 2001; Khodjakov and Rieder, 2001).”
Self-citationNoninvasive Imaging beyond the Diffraction Limit of 3D Dynamics in Thickly Fluorescent Specimens
Gao, L., Shao, L., Higgins, C. D., Poulton, J. S., Peifer, M., Davidson, M. W., Wu, X., Goldstein, B., & Betzig, E. (2012) · Cell · doi:10.1016/j.cell.2012.10.008 · Cited by 320 · cited 1×
“Images obtained by Bessel-beam microscopy are spectacular in both resolution and clarity, particularly when this technique is combined with structured illumination (Gao et al., 2012).”
The Spatial Arrangement of Chromosomes during Prometaphase Facilitates Spindle Assembly
Magidson, V., O'Connell, C. B., Lončarek, J., Paul, R., Mogilner, A., & Khodjakov, A. (2011) · Cell · doi:10.1016/j.cell.2011.07.012 · Cited by 312 · cited 2×
“, 2001) or when morphologically-similar objects exhibit distinctly different behavior (Magidson et al., 2011).”
Self-citationMajor signal increase in fluorescence microscopy through dark-state relaxation
Donnert, G., Eggeling, C., & Hell, S. W. (2007) · Nature Methods · doi:10.1038/nmeth986 · Cited by 291 · cited 3×
“…short pulses (shorter than the lifetime of excited fluorophores) separated by intervals that exceed the lifetime of the non-fluorescent but photobleaching-prone triplets have been shown to substantially reduce photobleaching in single-spot scanning confocal microscopy (Donnert et al., 2007).”
InfluentialKinetochore microtubule dynamics and the metaphase-anaphase transition.
Zhai, Y., Kronebusch, P. J., & Borisy, G. G. (1995) · The Journal of cell biology · doi:10.1083/jcb.131.3.721 · Cited by 289 · cited 1×
“Thus, although oxygen scavengers, for example oxyrase, have been successfully used in short-term live-cell recordings (Rodionov and Borisy, 1997; Zhai et al., 1995), this approach is not applicable when the goal is to obtain data from physiologically normal and healthy cell populations.”
Microtubule Treadmilling in Vivo
Rodionov, V. I., & Borisy, G. G. (1997) · Science · doi:10.1126/science.275.5297.215 · Cited by 165 · cited 1×
“Thus, although oxygen scavengers, for example oxyrase, have been successfully used in short-term live-cell recordings (Rodionov and Borisy, 1997; Zhai et al., 1995), this approach is not applicable when the goal is to obtain data from physiologically normal and healthy cell populations.”
Uetake, Y., Lončarek, J., Nordberg, J. J., English, C. N., Terra, S. L., Khodjakov, A. L., & Sluder, G. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200607073 · Cited by 165 · cited 2×
“However, subsequent investigations revealed that lowering the intensity of excitation light allows acentrosomal cells to progress through the entire cell cycle (Uetake et al., 2007).”
Self-citationParallelized STED fluorescence nanoscopy
Bingen, P., Reuss, M., Engelhardt, J., & Hell, S. W. (2011) · Optics Express · doi:10.1364/oe.19.023716 · Cited by 140 · cited 2×
“Potential solutions to this problem include simultaneous scanning of the sample with multiple beams (Bingen et al., 2011) as well as utilizing extremely fast scanners”
Nanoscopy in a Living Multicellular Organism Expressing GFP
Rankin, B. R., Moneron, G., Wurm, C. A., Nelson, J. C., Walter, A., Schwarzer, D., Schroeder, J., Colón‐Ramos, D. A., & Hell, S. W. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.05.020 · Cited by 120 · cited 3×
“longlifetime triplet-state fluorophores (Rankin et al., 2011).”
InfluentialMikhailov, A., Shinohara, M., & Rieder, C. L. (2005) · Cell Cycle · doi:10.4161/cc.4.1.1357 · Cited by 101 · cited 1×
“This sensitization can be suppressed to an extent by inhibition of p38 kinase (Mikhailov et al., 2005; Uetake et al., 2007), a major component of the stress-response pathway.”
LOTOS-based two-photon calcium imaging of dendritic spines in vivo
Chen, X., Leischner, U., Varga, Z., Jia, H., Deca, D., Rochefort, N. L., & Konnerth, A. (2012) · Nature Protocols · doi:10.1038/nprot.2012.106 · Cited by 73 · cited 1×
“With the latter approach extremely short dwell times (~50 ns) have been shown to noticeably decrease photobleaching and improve viability of brain cells imaged via multi-photon confocal microscopy (Chen et al., 2012).”
Speckle microscopic evaluation of microtubule transport in growing nerve processes
Chang, S., Svitkina, T., Borisy, G. G., & Popov, S. V. (1999) · Nature Cell Biology · doi:10.1038/15629 · Cited by 66 · cited 2×
“This approach has been proven quite beneficial when the objects are morphologically distinct (Chang et al., 1999; Tran et al., 2001) or when morphologically-similar objects exhibit distinctly different behavior (Magidson et al.”
The G2 p38-Mediated Stress-Activated Checkpoint Pathway Becomes Attenuated in Transformed Cells
Mikhailov, A. V., Patel, D., McCance, D. J., & Rieder, C. L. (2007) · Current Biology · doi:10.1016/j.cub.2007.11.028 · Cited by 19
Predictive‐focus illumination for reducing photodamage in live‐cell microscopy
SCHILLING, Z., FRANK, E., Magidson, V., Wason, J. D., Lončarek, J., BOYER, K., Wen, J. T.-Y., & Khodjakov, A. L. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03605.x · Cited by 13 · cited 7×
“Recently, a simple software based approach, termed Predictive-Focus Illumination (PFI) was introduced (Schilling et al., 2012).”
InfluentialSelf-citation
Cited by
Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition) 1
Klionsky, D. J., Abdel-Aziz, A. K., Abdelfatah, S., Abdellatif, M., Abdoli, A., Abel, S., Abeliovich, H., Abildgaard, M. H., Abudu, Y. P., Acevedo-Arozena, A., et al. (2021) · Autophagy · doi:10.1080/15548627.2020.1797280 · Cited by 2,897
Fluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634
Phototoxicity in live fluorescence microscopy, and how to avoid it
Icha, J., Weber, M., Waters, J. C., & Norden, C. (2017) · BioEssays · doi:10.1002/bies.201700003 · Cited by 622
Light-induced cell damage in live-cell super-resolution microscopy
Wäldchen, S., Lehmann, J., Klein, T., van de Linde, S., & Sauer, M. (2015) · Scientific Reports · doi:10.1038/srep15348 · Cited by 536
Assessing phototoxicity in live fluorescence imaging
Laissue, P. P., Alghamdi, R. A., Tomancak, P., Reynaud, E. G., & Shroff, H. (2017) · Nature Methods · doi:10.1038/nmeth.4344 · Cited by 510
Metadata
- Authors
- Magidson, V., & Khodjakov, A.
- Venue
- Methods in Cell Biology
- Publisher
- Elsevier
- Published
- 2013
- Volume
- 114
- Pages
- 545-560
- ISSN
- 0091-679X (ISSN-L)
- OpenAlex
- W1896713956
- Cited by
- 231
- References
- 23
- FWCI
- 16.17
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.