Electrocorticography and functional mapping
The DOI matches its Crossref record; 64 of the 66 references it cites were found in a registry or an index.
Abstract
Brain mapping is often critical to the success of epilepsy and brain tumor surgeries. Mapping the cerebral cortex can be performed either extraoperatively or intraoperatively. When considering the optimal venue for a particular patient, a number of important considerations need to be considered including: the intended goals for the mapping, patient factors, anesthetic effects, stimulation parameters, cortical functions of interest, as well as the mapping modalities being considered. In this chapter, we will cover electrocorticography, cortical somatosensory evoked potentials, and the various neurophysiologic techniques used to map sensorimotor and cognitive functions, including language. One of the main uses of electrocorticography in epilepsy surgery is to map the cortical regions associated with epileptiform activity. This information is used to plan resection boundaries. Electrocorticography can also be used to monitor for afterdischarges (ADs) during direct cortical stimulation as well as for mapping high-frequency activity during various cognitive tasks. Cortical somatosensory evoked potentials can identify the central sulcus by mapping the dipolar activation of the primary somatosensory cortex that results from stimulation of the large fiber somatosensory pathway by peripheral nerve stimulation. Motor, sensory, and language cortex can also be identified by direct electrical cortical stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“ECoG has been used clinically for decades for localizing seizures and for brain mapping in surgical work-up for epilepsy treatment90.”
From The speech neuroprosthesis (2024) · cites this paper as [90]
In the citing paper
“Previously, data on the long-term safety and stability of ECoG primarily came from its application in epilepsy82,90–92, including the paddle-style surface strip electrodes with the Neuropace responsive neurostimulation system, which has demonstrated safety and signal stability for at least 9 years92.”
From The speech neuroprosthesis (2024) · cites this paper as [90]
Citations
Cites
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Hickok, G., & Poeppel, D. (2004) · Cognition · doi:10.1016/j.cognition.2003.10.011 · Cited by 2,212
Functional Outcome after Language Mapping for Glioma Resection
Sanai, N., Mirzadeh, Z., & Berger, M. S. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa067819 · Cited by 1,065
Palmini, A., Gambardella, A., Andermann, F., Dubeau, F., da Costa, J. C., Olivier, A., Tampieri, D., Gloor, P., Quesney, F., Andermann, E., et al. (1995) · Annals of Neurology · doi:10.1002/ana.410370410 · Cited by 754
High‐frequency oscillations as a new biomarker in epilepsy
Zijlmans, M., Jiruska, P., Zelmann, R., Leijten, F. S. S., Jefferys, J. G. R., & Gotman, J. (2012) · Annals of Neurology · doi:10.1002/ana.22548 · Cited by 524
Lachaux, J.-P., Axmacher, N., Mormann, F., Halgren, E., & Crone, N. E. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.06.008 · Cited by 506
Stimulation mapping of white matter tracts to study brain functional connectivity.
Duffau, H. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.51 · Cited by 437
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Yamakura, T., & Harris, R. A. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00034 · Cited by 367
Cited by
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
Soft, conformal PDMS-based ECoG electrode array for long-term in vivo applications
Moon, H., Jang, J., Park, S., Kim, J.-H., Kim, J. S., & Kim, S. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.135099 · Cited by 40
Entropy and Complexity Tools Across Scales in Neuroscience: A Review
Cofré, R., & Destexhe, A. (2025) · Entropy · doi:10.3390/e27020115 · Cited by 30
“ECoG captures continuous electrical signals representing the aggregate activity of neuronal populations with greater spatial and temporal resolutions compared to non-invasive methods (like EEG or MEG), enabling precise mapping of neural processes [35].”
Clinical neuroscience and neurotechnology: An amazing symbiosis
Cometa, A., Falasconi, A., Biasizzo, M., Carpaneto, J., Horn, A., Mazzoni, A., & Micera, S. (2022) · iScience · doi:10.1016/j.isci.2022.105124 · Cited by 24
Brain‐to‐brain interface technology: A brief history, current state, and future goals
Vakilipour, P., & Fekrvand, S. (2024) · International Journal of Developmental Neuroscience · doi:10.1002/jdn.10334 · Cited by 15
“Semi-invasive BCIs use electrocorticography, which is the electroencephalographic (EEG) recording made with intracranial subdural or depth electrodes (Vakani & Nair, 2019), to identify electrical impulses deriving from the cerebral cortex.”
Risk Factors for Intraoperative Seizures in Glioma Surgery: Electrocorticography Matters
Lettieri, C., Ius, T., Verriello, L., Budai, R., Isola, M., Valente, M., Škrap, M., Gigli, G. L., & Pauletto, G. (2021) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000854 · Cited by 14
Yan, T., Suzuki, K., Kameda, S., Kuratomi, T., Mihara, M., Maeda, M., & Hirata, M. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3210286 · Cited by 9
Idris, Z., Yee, A. S., Hassan, W. M. N. W., Hassan, M. H., Zain, K. A. M., & Manaf, A. A. (2021) · Therapeutic Hypothermia and Temperature Management · doi:10.1089/ther.2020.0033 · Cited by 8
“The gold standard of ECoG in detecting abnormal human brainwaves is well documented in epilepsy and brain mapping study (Idris et al. , 2013; Benbadis et al. , 2018; Vakani and Nair, 2019).”
Rapid loss of consciousness in cattle following nonstun slaughter: evidence from a systematic review
Hascalovici, J., Schipper, H. M., Regenstein, J. M., Rosen, S. D., Zivotofsky, A. Z., St‐Jean, G., Freilich, S., Morrison, T., Rabkin, S. W., & Haut, S. R. (2025) · American Journal of Veterinary Research · doi:10.2460/ajvr.25.02.0049 · Cited by 7
Straumann, S., Schaft, E. V., Noordmans, H. J., Dankbaar, J. W., Otte, W. M., van Steenis, J. L., Smits, P. L., Zweiphenning, W. J. E. M., van Eijsden, P., Gebbink, T. A., et al. (2022) · Brain Communications · doi:10.1093/braincomms/fcac302 · Cited by 8
“Intraoperative electrocorticography (ioECoG) can assist the localization of the EZ beyond the margins of MRI lesions,5,7,20–22 particularly in patients with neocortical lesions.5,23 A surgical strategy that combines a complete resection of the MRI lesion and resecting epileptogenic tissue identified through ioECoG has…”
InfluentialConsciousness and Energy Processing in Neural Systems
Pepperell, R. (2024) · Brain Sciences · doi:10.3390/brainsci14111112 · Cited by 7
Shu, Y., Yang, S., Li, P., Gou, S., Cheng, Y., Jia, Q., & Du, Z. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1476447 · Cited by 4
Menlibayeva, K., Nurimanov, C., Mammadinova, I. Z., Туржанова, А., Akshulakov, S. K., & Makhambetov, Y. T. (2025) · Brain Sciences · doi:10.3390/brainsci15090992 · Cited by 3
“Advanced surgical techniques, such as 3.0 Tesla MRI with an epilepsy-specific protocol, intraoperative electrocorticography, modern navigation systems, and cortical mapping, are critical for achieving seizure freedom after surgery [32,33].”
InfluentialShen, Y., You, C., Zhang, Y. X., Ji, N., Zhao, X., Zhang, P., Huang, S., Kang, H., Liu, X., Peng, Y., et al. (2026) · Epilepsia · doi:10.1002/epi.70273 · Cited by 3
Cepero-Escribano, V., León-Cabrera, P., Olivé, G., Cucurell, D., Gasa‐Roqué, A., Gabarrós, A., Naval‐Baudin, P., Camins, À., Rico, I., Coello, A. F., et al. (2024) · Cortex · doi:10.1016/j.cortex.2024.05.022 · Cited by 3
“A left parietal craniotomy was performed, and the ESM was carried out using an ISIS Xpert 32 channels system (Inomed Medizintechnnik GmbH) under asleep-awake-asleep surgery, following the methodology previously described by Ojemann and Mateer (1979) and Vakani and Nair (2019).”
A Novel Intraoperative Mapping Device Detects the Thermodynamic Response Function
Iorga, M., Schneider, N., Cho, J., Tate, M. C., & Parrish, T. B. (2023) · Brain Sciences · doi:10.3390/brainsci13071091 · Cited by 3
“Additionally, electrocorticography has been used for some time to track discharges during epilepsy surgery [36] and is also viable as an intraoperative mapping tool for complex functions [37,38].”
MethodRecording from the brain: an introduction
Valeriani, D., & Vaughan, T. M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24824-5.00022-3 · Cited by 1
Bustros, S., Kaur, M., Ritchey, E., Szaflarski, J. P., McGwin, G., Riley, K. O., Bentley, J. N., Memon, A., & Jaisani, Z. (2024) · Neurological Research · doi:10.1080/01616412.2024.2340879 · Cited by 1
“Intraoperative electrocorticography (ECoG) was performed in some patients who had resection to map the extent of epileptogenic cortex resection or to preserve the functional cortex [23].”
MethodSub-scalp EEG for sensorimotor brain–computer interface
Mahoney, T., Grayden, D. B., & John, S. E. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade9f1 · Cited by 1
“This is commonly seen in intracranial electrodes, such as ECoG [56], but has also been demonstrated non-invasively with ultra high density EEG [47].”
Long, M., Thiaghu, C., Cheong, T. M., Kirollos, R. W., Han, J. X., Ng, L. P., & Low, S. Y. Y. (2025) · Journal of Personalized Medicine · doi:10.3390/jpm15070319 · Cited by 1
Marawar, R., Klinger, N. V., Tarbox, S. I., Mittal, S., & Shah, A. K. (2020) · Epilepsy & Behavior Reports · doi:10.1016/j.ebr.2020.100403
“2 sulcus closest to the electrode showing phase reversal of N20 peak during bipolar recording in anterior-posterior fashion, while the highest amplitude of the N20 during referential recording defines the hand sensory area [14].”
BackgroundLetter: A Review of Passive Brain Mapping Techniques in Neurological Surgery
Muñoz-Báez, K., Lozada-Martínez, I. D., Moscote‐Salazar, L. R., Rahman, M. M., & Agrawal, A. (2021) · Neurosurgery · doi:10.1093/neuros/nyab114
Bearden, D. J., Ehrenberg, A., Harrington, R. M., Selawski, R., Abbeduto, L., Lee, S. M., Maddox, S., Alfonso, D., Kaestner, E. J., Dabiri, S., et al. (2024) · OSF Preprints (OSF Preprints) · doi:10.31219/osf.io/3ascm
Masohood, N. S., Paquin-Lanthier, G., Chui, J., Lu, N., Chowdhury, T., & Venkatraghavan, L. (2023) · Journal of Neuroanaesthesiology and Critical Care · doi:10.1055/s-0043-1777444
Advancements in Awake Glioma Surgery
Pesce, A., Dimichele, G., Novegno, F., Armocida, D., Frati, A., & Salvati, M. (2025) · Springer eBooks · doi:10.1007/978-3-031-81850-9_15
Exploring Neural Mechanisms Underlying High-Dimensional Brain ActivityPreprint
Tozzi, A. (2025) · SSRN Electronic Journal · doi:10.20944/preprints202506.0434.v1 · Cited by 1
Fan, J. L., Lee, K., Tchoe, Y., Ganji, M., Vatsyayan, R., Yoon, H. Y., Garrett, J., Dayeh, S. A., Halgren, E., & Ji, N. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.28.685211
Cruz, R. A., de Souza, J. P. S. A. S., Aragon, D. C., Thomé, Ú., Hamad, A. P. A., Sakamoto, A. C., dos Santos, A. C., Machado, H. R., & Santos, M. V. (2026) · Epileptic Disorders · doi:10.1002/epd2.70160
Patient Outcomes and Quality of Electrocorticography in Pediatric Epilepsy Surgery: A Case Series
Luo, J., Barker, N., Crawford, C. J., Singhal, A., Huh, L. L., & Bailey, K. M. (2026) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000001116
Metadata
- Authors
- Vakani, R., & Nair, D. R.
- Affiliations
- Cedars-Sinai Medical Center (US)
- Cleveland Clinic (US)
- Corresponding author
- Dileep R Nair
- ORCID
- Dileep R Nair
- Venue
- Handbook of Clinical Neurology
- Publisher
- Elsevier
- Published
- 2019
- Volume
- 160
- Pages
- 313-327
- ISSN
- 0072-9752 (ISSN-L)
- OpenAlex
- W2953966375
- Semantic Scholar
- 66117dd685ab89c33f7af6eb5a20f0e475900235
- Cited by
- 28
- References
- 66
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 7 · 2023: 3 · 2022: 3 · 2021: 3 · 2020: 1
- FWCI
- 7.59
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Handbook of clinical neurology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Surgery › Intraoperative Neuromonitoring and Anesthetic Effects
- Keywords
- electrocorticography, functional brain mapping, epilepsy surgery, brain tumor surgery, cortical somatosensory evoked potentials, language mapping, motor cortex mapping, central sulcus, afterdischarge, epileptiform activity
- MeSH terms
- Electrocorticography, Brain Mapping, Electroencephalography, Humans, Somatosensory Cortex, Monitoring, Intraoperative
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.