Electrocorticography and functional mapping
The DOI matches its Crossref record; 63 of the 66 references it cites were found in a registry or an index.
Abstract
Brain mapping is often critical to the success of epilepsy and brain tumor surgeries. Mapping the cerebral cortex can be performed either extraoperatively or intraoperatively. When considering the optimal venue for a particular patient, a number of important considerations need to be considered including: the intended goals for the mapping, patient factors, anesthetic effects, stimulation parameters, cortical functions of interest, as well as the mapping modalities being considered. In this chapter, we will cover electrocorticography, cortical somatosensory evoked potentials, and the various neurophysiologic techniques used to map sensorimotor and cognitive functions, including language. One of the main uses of electrocorticography in epilepsy surgery is to map the cortical regions associated with epileptiform activity. This information is used to plan resection boundaries. Electrocorticography can also be used to monitor for afterdischarges (ADs) during direct cortical stimulation as well as for mapping high-frequency activity during various cognitive tasks. Cortical somatosensory evoked potentials can identify the central sulcus by mapping the dipolar activation of the primary somatosensory cortex that results from stimulation of the large fiber somatosensory pathway by peripheral nerve stimulation. Motor, sensory, and language cortex can also be identified by direct electrical cortical stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“ECoG has been used clinically for decades for localizing seizures and for brain mapping in surgical work-up for epilepsy treatment90.”
From The speech neuroprosthesis (2024) · cites this paper as [90]
In the citing paper
“Previously, data on the long-term safety and stability of ECoG primarily came from its application in epilepsy82,90–92, including the paddle-style surface strip electrodes with the Neuropace responsive neurostimulation system, which has demonstrated safety and signal stability for at least 9 years92.”
From The speech neuroprosthesis (2024) · cites this paper as [90]
Citations
Cites
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Hickok, G., & Poeppel, D. (2004) · Cognition · doi:10.1016/j.cognition.2003.10.011 · Cited by 2,212
Functional Outcome after Language Mapping for Glioma Resection
Sanai, N., Mirzadeh, Z., & Berger, M. S. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa067819 · Cited by 1,065
Palmini, A., Gambardella, A., Andermann, F., Dubeau, F., da Costa, J. C., Olivier, A., Tampieri, D., Gloor, P., Quesney, F., Andermann, E., et al. (1995) · Annals of Neurology · doi:10.1002/ana.410370410 · Cited by 754
High‐frequency oscillations as a new biomarker in epilepsy
Zijlmans, M., Jiruska, P., Zelmann, R., Leijten, F. S. S., Jefferys, J. G. R., & Gotman, J. (2012) · Annals of Neurology · doi:10.1002/ana.22548 · Cited by 524
Lachaux, J.-P., Axmacher, N., Mormann, F., Halgren, E., & Crone, N. E. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.06.008 · Cited by 506
Stimulation mapping of white matter tracts to study brain functional connectivity.
Duffau, H. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.51 · Cited by 437
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Yamakura, T., & Harris, R. A. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00034 · Cited by 367
Propofol: A Review of its Role in Pediatric Anesthesia and Sedation
Chidambaran, V., Costandi, A., & D’Mello, A. (2015) · CNS Drugs · doi:10.1007/s40263-015-0259-6 · Cited by 356
Removing interictal fast ripples on electrocorticography linked with seizure freedom in children
Wu, J. Y., Sankar, R., Lerner, J. T., Matsumoto, J. H., Vinters, H. V., & Mathern, G. W. (2010) · Neurology · doi:10.1212/wnl.0b013e3181fc27d0 · Cited by 306
Complications of invasive video-EEG monitoring with subdural grid electrodes
Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., et al. (2002) · Neurology · doi:10.1212/wnl.58.1.97 · Cited by 289
Pro-and Anticonvulsant Effects of Anesthetics (Part I)
Modica, P. A., Tempelhoff, R., & White, P. F. (1990) · Anesthesia & Analgesia · doi:10.1213/00000539-199003000-00013 · Cited by 270
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E. (2005) · Brain · doi:10.1093/brain/awh491 · Cited by 266
High frequency oscillations in the intact brain
Buzsáki, G., & Silva, F. L. D. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.02.004 · Cited by 252
Seizure-like phenomena and propofol: A systematic review
Walder, B., Tramèr, M. R., & Seeck, M. (2002) · Neurology · doi:10.1212/wnl.58.9.1327 · Cited by 248
Mirsattari, S. M., Sharpe, M. D., & Young, G. B. (2004) · Archives of Neurology · doi:10.1001/archneur.61.8.1254 · Cited by 248
Epileptic Seizures: Pathophysiology And Clinical Semiology
Lüders, H. O., & Noachtar, S. (2000) · Cited by 241
A fingerprint of the epileptogenic zone in human epilepsies
Grinenko, O., Li, J., Mosher, J. C., Wang, I. Z., Bulacio, J. C., Gonzalez-Martinez, J., Nair, D., Najm, I., Leahy, R. M., & Chauvel, P. (2018) · Brain · doi:10.1093/brain/awx306 · Cited by 226
Self-citationCortical somatosensory evoked potentials in response to hand stimulation
Lueders, H., Lesser, R. P., Hahn, J., Dinner, D. S., & Klem, G. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.58.6.0885 · Cited by 215
Stereotactic placement of depth electrodes in medically intractable epilepsy: Technical note
Gonzalez-Martinez, J., Mullin, J., Vadera, S., Bulacio, J., Hughes, G., Jones, S., Enatsu, R., & Najm, I. (2014) · Journal of Neurosurgery · doi:10.3171/2013.11.jns13635 · Cited by 209
Electrical Stimulation for Seizure Induction and Functional Mapping in Stereoelectroencephalography
Trébuchon, A., & Chauvel, P. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000313 · Cited by 161
Elektrobiologische Vorgänge an der menschlichen Hirnrinde
Foerster, O., & Altenburger, H. (1935) · Journal of Neurology · doi:10.1007/bf01732786 · Cited by 156
Chronic subdural electrodes in the management of epilepsy
Nair, D. R., Burgess, R. C., McIntyre, C. C., & Lüders, H. O. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.117 · Cited by 147
Self-citationSouter, M. J., Rozet, I., Ojemann, J. G., Souter, K. J., Holmes, M., Lee, L., & Lam, A. M. (2006) · Journal of Neurosurgical Anesthesiology · doi:10.1097/01.ana.0000211027.26550.24 · Cited by 146
Allison, T., McCarthy, G., Luby, M., Puce, A., & Spencer, D. D. (1996) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0013-4694(95)00226-x · Cited by 144
Pro- and Anticonvulsant Effects of Anesthetics (Part II)
Modica, P. A., Tempelhoff, R., & White, P. F. (1990) · Anesthesia & Analgesia · doi:10.1213/00000539-199004000-00016 · Cited by 141
Why we still use intravenous drugs as the basic regimen for neurosurgical anaesthesia
Hans, P., & Bonhomme, V. L. (2006) · Current Opinion in Anaesthesiology · doi:10.1097/01.aco.0000245274.69292.ad · Cited by 140
Mandonnet, E., Sarubbo, S., & Duffau, H. (2016) · Neurosurgical Review · doi:10.1007/s10143-016-0723-x · Cited by 121
The neurolinguistic approach to awake surgery reviewed
Witte, E. D., & Mariën, P. (2012) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2012.09.015 · Cited by 114
Intraoperative ElectroCorticoGraphy (ECog): indications, techniques, and utility in epilepsy surgery
Yang, T., Hakimian, S., & Schwartz, T. H. (2014) · Epileptic Disorders · doi:10.1684/epd.2014.0675 · Cited by 113
[Hans Berger (1873-1941)--the history of electroencephalography].
Tudor, M., Car, L. T., & Tudor, K. I. (2005) · PubMed · Cited by 93
Significance of spikes recorded on electrocorticography in nonlesional medial temporal lobe epilepsy
Tran, T. A., Spencer, S. S., Marks, D. A., Javidan, M., Pacia, S. V., & Spencer, D. D. (1995) · Annals of Neurology · doi:10.1002/ana.410380511 · Cited by 82
Herrick, I. A., Craen, R. A., Gelb, A. W., McLachlan, R. S., Girvin, J. P., Parrent, A. G., Eliasziw, M., & Kirkby, J. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199706000-00020 · Cited by 79
Intraoperative Localization of an Epileptogenic Focus with Alfentanil and Fentanyl
Manninen, P. H., Burke, S. J., Wennberg, R. A., Lozano, A. M., & Beheiry, H. E. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199905000-00025 · Cited by 77
Balzamo, E., Marquis, P., Chauvel, P., & Régis, J. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.012 · Cited by 77
PROPROFOL AND THE ELECTROENCEPHALOGRAM
Hodkinson, B., Frith, R., & Mee, E. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92644-4 · Cited by 73
Cortical generators of somatosensory evoked potentials to median nerve stimulation
Dinner, D. S., Lüders, H. O., Lesser, R. P., & Morris, H. H. (1987) · Neurology · doi:10.1212/wnl.37.7.1141 · Cited by 70
Wass, C. T., Grady, R. E., Fessler, A. J., Cascino, G. D., Lozada, L., Bechtle, P. S., Marsh, W. R., Sharbrough, F. W., & Schroeder, D. R. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.05901.x · Cited by 68
Electrocorticography for Seizure Foci Mapping in Epilepsy Surgery
Fernández, I. S., & Loddenkemper, T. (2013) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000436898.10125.70 · Cited by 64
Hisada, K., Morioka, T., Fukui, K., Nishio, S., KURUMA, T., Irita, K., Takahashi, S., & Fukui, M. (2001) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-200110000-00010 · Cited by 60
Samra, S. K., Sneyd, J. R., Ross, D. A., & Henry, T. R. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00005 · Cited by 58
The Stereo-Electroencephalography: The Epileptogenic Zone
Gonzalez-Martinez, J. A. (2016) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000327 · Cited by 58
Ikeda, A., Miyamoto, S., & Shibasaki, H. (2002) · Epilepsia · doi:10.1046/j.1528-1157.43.s.9.13.x · Cited by 56
Proceedings of the Third International Workshop on Advances in Electrocorticography
Ritaccio, A., Beauchamp, M., Bosman, C., Brunner, P., Chang, E., Crone, N., Gunduz, A., Gupta, D., Knight, R., Leuthardt, E., et al. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2012.09.016 · Cited by 56
Increased neocortical spiking and surgical outcome after selective amygdalo-hippocampectomy
Cendes, F., Dubeau, F., Olivier, A., Cukiert, A., Andermann, E., QUESNEY, L. F., & Andermann, F. (1993) · Epilepsy Research · doi:10.1016/0920-1211(93)90080-q · Cited by 51
Penfield, W. (1956) · PubMed · Cited by 51
Cortical stimulation parameters for functional mapping
Corley, J. A., Nazari, P., Rossi, V. J., Kim, N. C., Fogg, L., Hoeppner, T. J., Stoub, T. R., & Byrne, R. W. (2016) · Seizure · doi:10.1016/j.seizure.2016.11.015 · Cited by 46
Masking of Epileptiform Activity by Propofol during Seizure Surgery
Drummond, J. C., Iragui‐Madoz, V., Alksne, J. F., & Kalkman, C. J. (1992) · Anesthesiology · doi:10.1097/00000542-199204000-00029 · Cited by 41
Cottrell and Young’s Neuroanesthesia
Smith, M. (2011) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06618.x · Cited by 39
Effect of Isoflurane (Forane) on Intraoperative Electrocorticogram
Fiol, M. E., Boening, J. A., Cruz‐Rodriguez, R., & Maxwell, R. E. (1993) · Epilepsia · doi:10.1111/j.1528-1157.1993.tb02108.x · Cited by 39
Presurgical Assessment of the Epilepsies with Clinical Neurophysiology and Functional Imaging
(2003) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(00)x0002-0 · Cited by 37
Effects of Sevoflurane on Electrocorticography in Patients With Intractable Temporal Lobe Epilepsy
Endo, T., Sato, K., Shamoto, H., & Yoshimoto, T. (2002) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-200201000-00012 · Cited by 33
[Surgical indications in so-called temporal epilepsy].
Guillaume, J., Mazars, G., & Mazars, Y. (1953) · PubMed · Cited by 32
Bindra, A., Chouhan, R. S., Prabhakar, H., Dash, H. H., Chandra, P. S., & Tripathi, M. (2012) · Seizure · doi:10.1016/j.seizure.2012.05.002 · Cited by 24
Effects of nitrous oxide on electrocorticography during epilepsy surgery
Hosain, S. A., Nagarajan, L., Fraser, R. A. R., Poznak, A. V., & Labar, D. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95028-2 · Cited by 23
Effects of Propofol on Electrocorticography in Patients With Intractable Partial Epilepsy
Schneider, F., Herzer, W., Schroeder, H. W. S., Mueller, J. U., Kolyschkow, P., Sommer, M., Piek, J., Kessler, C., & Runge, U. (2010) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0b013e3181ff6024 · Cited by 17
Proceedings of the Fifth International Workshop on Advances in Electrocorticography
Ritaccio, A. L., Brunner, P., Gunduz, A., Hermes, D., Hirsch, L. J., Jacobs, J., Kamada, K., Kästner, S., Knight, R. T., Lesser, R. P., et al. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.09.015 · Cited by 17
Long-term surgical results of supplementary motor area epilepsy surgery
Alonso‐Vanegas, M., San‐Juan, D., García, R. M. B., Castillo‐Montoya, C., Sentíes-Madrid, H., Mascher, E. B., Bialik, P. S., & Trenado, C. (2017) · Journal of neurosurgery · doi:10.3171/2016.8.jns16333 · Cited by 14
[Surgical indications in the so-called temporal epilepsy].
Guillaume, J., Mazars, G., & Mazars, Y. (1953) · PubMed · Cited by 10
AWAKE CRANIOTOMY, EPILEPSY, MINIMALLY INVASIVE, AND ROBOTIC SURGERY
Schubert, A., & Lotto, M. L. (2010) · Elsevier eBooks · doi:10.1016/b978-0-323-05908-4.10022-3 · Cited by 9
Cortical somatosensory evoked potential mapping
Iwasaki, M., Nair, D. R., & Lüders, H. O. (2003) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(03)03021-1 · Cited by 4
Self-citation
Cited by
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
Soft, conformal PDMS-based ECoG electrode array for long-term in vivo applications
Moon, H., Jang, J., Park, S., Kim, J.-H., Kim, J. S., & Kim, S. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.135099 · Cited by 40
Entropy and Complexity Tools Across Scales in Neuroscience: A Review
Cofré, R., & Destexhe, A. (2025) · Entropy · doi:10.3390/e27020115 · Cited by 30
“ECoG captures continuous electrical signals representing the aggregate activity of neuronal populations with greater spatial and temporal resolutions compared to non-invasive methods (like EEG or MEG), enabling precise mapping of neural processes [35].”
Clinical neuroscience and neurotechnology: An amazing symbiosis
Cometa, A., Falasconi, A., Biasizzo, M., Carpaneto, J., Horn, A., Mazzoni, A., & Micera, S. (2022) · iScience · doi:10.1016/j.isci.2022.105124 · Cited by 24
Brain‐to‐brain interface technology: A brief history, current state, and future goals
Vakilipour, P., & Fekrvand, S. (2024) · International Journal of Developmental Neuroscience · doi:10.1002/jdn.10334 · Cited by 15
“Semi-invasive BCIs use electrocorticography, which is the electroencephalographic (EEG) recording made with intracranial subdural or depth electrodes (Vakani & Nair, 2019), to identify electrical impulses deriving from the cerebral cortex.”
Metadata
- Authors
- Vakani, R., & Nair, D. R.
- Affiliations
- Cedars-Sinai Medical Center (US)
- Cleveland Clinic (US)
- Corresponding author
- Dileep R Nair
- ORCID
- Dileep R Nair
- Venue
- Handbook of Clinical Neurology
- Publisher
- Elsevier
- Published
- 2019
- Volume
- 160
- Pages
- 313-327
- ISSN
- 0072-9752 (ISSN-L)
- OpenAlex
- W2953966375
- Cited by
- 28
- References
- 66
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 7 · 2023: 3 · 2022: 3 · 2021: 3 · 2020: 1
- FWCI
- 7.59
- Type
- book chapter
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Handbook of clinical neurology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Surgery › Intraoperative Neuromonitoring and Anesthetic Effects
- Keywords
- electrocorticography, functional brain mapping, epilepsy surgery, brain tumor surgery, cortical somatosensory evoked potentials, language mapping, motor cortex mapping, central sulcus, afterdischarge, epileptiform activity
- MeSH terms
- Electrocorticography, Brain Mapping, Electroencephalography, Humans, Somatosensory Cortex, Monitoring, Intraoperative
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.