Cited by 28

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Blood Glucose Determination: Effect of Tube Additives

·2018·Advances in Clinical Chemistry

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/bs.acc.2017.12.003

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 39

  1. Narla, 2016, Critical care glucose point-of-care testing, Adv. Clin. Chem., 76, 97, 10.1016/bs.acc.2016.05.002 · DOI
  2. Lippi, 2012, Haemoglobin A1c and diagnosis of diabetes, not ready for the prime time?, Ann. Clin. Biochem., 49, 508, 10.1258/acb.2012.012026 · DOI
  3. Mikesh, 2008, Stabilization of glucose in blood specimens: mechanism of delay in fluoride inhibition of glycolysis, Clin. Chem., 54, 930, 10.1373/clinchem.2007.102160 · DOI
  4. Peake, 2013, It's time for a better blood collection tube to improve the reliability of glucose results, Diabetes Care, 36, 10.2337/dc12-1312 · DOI
  5. Montagnana, 2017, Overcoming preanalytical issues for diagnosing diabetes with fasting plasma glucose, Ann. Transl. Med., 5, 257, 10.21037/atm.2017.05.19 · DOI
  6. Sacks, 2011, Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Clin. Chem., 57, 793, 10.1373/clinchem.2011.163634 · DOI
  7. Lippi, 2012, Laboratory networking and sample quality: a still relevant issue for patient safety, Clin. Chem. Lab. Med., 50, 1703, 10.1515/cclm-2012-0245 · DOI
  8. van den Berg, 2015, Inventarisatie van de (pre)analytische aspecten van de glucose bepaling in nederlandse laboratoria; tijd voor uniformiteit, Ned. Tijdschr. Klin. Chem. Labgeneesk, 40, 68
  9. Pasqualetti, 2016, Optimal collection tubes for plasma glucose determination: confusion reigns supreme, Clin. Chem. Lab. Med., 54, e281, 10.1515/cclm-2016-0137 · DOI
  10. Bruns, 2013, Are fluoride-containing blood tubes still needed for glucose testing?, Clin. Biochem., 46, 289, 10.1016/j.clinbiochem.2013.01.009 · DOI
  11. Gambino, 2013, Sodium fluoride: an ineffective inhibitor of glycolysis, Ann. Clin. Biochem., 50, 3, 10.1258/acb.2012.012135 · DOI
  12. Yagmur, 2012, Effective inhibition of glycolysis in venous whole blood and plasma samples, J. Lab. Med., 36, 169
  13. del Pino, 2013, Citric/citrate buffer: an effective antiglycolytic agent, Clin. Chem. Lab. Med., 51, 1943, 10.1515/cclm-2012-0735 · DOI
  14. Longini, 2014, Management of blood glucose in the clinical analysis laboratory: evaluation of old and new inhibitors of glycolysis. Preliminary data, Riv. Ital. Med. Lab., 10, 44, 10.1007/s13631-013-0047-6 · DOI
  15. Szoke, 2014, Better blood collection tubes for plasma glucose: ready for prime time?, Clin. Chem. Lab. Med., 52, e87, 10.1515/cclm-2013-1006 · DOI
  16. Fobker, 2014, Stability of glucose in plasma with different anticoagulants, Clin. Chem. Lab. Med., 52, 1057, 10.1515/cclm-2013-1049 · DOI · Paper page
  17. Dimeski, 2015, What is the most suitable blood collection tube for glucose estimation?, Ann. Clin. Biochem., 52, 270, 10.1177/0004563214544708 · DOI
  18. van den Berg, 2015, It takes acid, rather than ice, to freeze glucose, Sci. Rep., 5, 8875, 10.1038/srep08875 · DOI · Paper page
  19. van den Berg, 2015, Pregnancy diabetes: a comparison of diagnostic protocols based on point-of-care, routine and optimized laboratory condition, Sci. Rep., 5, 16302, 10.1038/srep16302 · DOI
  20. Bonetti, 2016, Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis, Biochem. Med. (Zagreb), 26, 68, 10.11613/BM.2016.006 · DOI
  21. Juricic, 2016, Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes, Clin. Chem. Lab. Med., 54, 411, 10.1515/cclm-2015-0746 · DOI
  22. Carey, 2016, Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation, Clin. Biochem., 49, 1406, 10.1016/j.clinbiochem.2016.05.017 · DOI · Paper page
  23. Bonetti, 2016, Which sample tube should be used for routine glucose determination?, Prim. Care Diabetes, 10, 227, 10.1016/j.pcd.2015.11.003 · DOI
  24. Gupta, 2016, A study to compare the plasma glucose levels obtained in sodium fluoride and citrate buffer tubes at a tertiary care hospital in Punjab, Int. J. Appl. Basic Med. Res., 6, 50, 10.4103/2229-516X.174010 · DOI
  25. Juricic, 2016, The evidence for clinically significant bias in plasma glucose between liquid and lyophilized citrate buffer additive, Clin. Biochem., 49, 1402, 10.1016/j.clinbiochem.2016.03.006 · DOI
  26. Zhang, 2016, Glucose stability study: NaF/citrate plasma versus serum, Clin. Lab., 62, 389, 10.7754/Clin.Lab.2015.150712 · DOI
  27. van der Hagen, 2017, Technical and clinical validation of the Greiner FC-Mix glycaemia tube, Clin. Chem. Lab. Med., 55, 1530, 10.1515/cclm-2016-0944 · DOI
  28. Stapleton, 2017, Time and temperature affect glycolysis in blood samples regardless of fluoride-based preservatives: a potential underestimation of diabetes, Ann. Clin. Biochem., 54, 671, 10.1177/0004563216682978 · DOI
  29. Juricic, 2016, Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes, Clin. Chem. Lab. Med., 54, 363, 10.1515/cclm-2015-0358 · DOI
  30. Dimeski, 2017, Evaluation of the accuracy of the Greiner Bio-One FC Mix Glucose tube, Clin. Chem. Lab. Med., 55, e96
  31. Simundic, 2010, Hemolysis detection and management of hemolysed specimens, Biochem. Med. (Zagreb), 20, 154, 10.11613/BM.2010.018 · DOI
  32. Chan, 1989, Effectiveness of sodium fluoride as a preservative of glucose in blood, Clin. Chem., 35, 315, 10.1093/clinchem/35.2.315 · DOI · Paper page
  33. Major, 1923, Potassium fluoride as a preservative for blood, JAMA, 81, 1952, 10.1001/jama.1923.26510230002012a · DOI
  34. Ricos, 1999, Current databases on biologic variation: pros, cons and progress, Scand. J. Clin. Lab. Invest., 59, 491, 10.1080/00365519950185229 · DOI · Paper page
  35. Grafmeyer, 1995, The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study, Eur. J. Clin. Chem. Clin. Biochem., 33, 31
  36. Koseoglu, 2011, Effects of hemolysis interference on routine biochemistry parameters, Biochem. Med. (Zagreb), 21, 79, 10.11613/BM.2011.015 · DOI
  37. Ridefelt, 2014, Increased plasma glucose levels after change of recommendation from NaF to citrate blood collection tubes, Clin. Biochem., 47, 625, 10.1016/j.clinbiochem.2014.02.022 · DOI · Paper page
  38. Norman, 2014, The shift from fluoride/oxalate to acid citrate/fluoride blood collection tubes for glucose testing—the impact upon patient results, Clin. Biochem., 47, 683, 10.1016/j.clinbiochem.2014.01.011 · DOI
  39. Gambino, 2013, Stabilization of glucose in blood samples: out with the old, in with the new, Clin. Chem. Lab. Med., 51, 1883, 10.1515/cclm-2013-0341 · DOI

Cited by

Sorted by citations

See all 28

Metadata

Venue
Advances in Clinical Chemistry
Publisher
Elsevier
Published
2018
Pages
101-123
ISSN
0065-2423
Cited by
28
References
6
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›