CoChat

Vitamin C in mouse and human red blood cells: An HPLC assay

Open access
Li, Hongyan, Tu, Hongbin, Wang, Yaohui, Levine, Mark · 2012 · Analytical Biochemistry
Cited by 39

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Although vitamin C (ascorbate) is present in whole blood, measurements in red blood cells (RBCs) are problematic because of interference, instability, limited sensitivity, and sample volume requirements. We describe a new technique using HPLC with coulometric electrochemical detection for ascorbate measurement in RBCs of humans, wild-type mice, and mice unable to synthesize ascorbate. Exogenously added ascorbate was fully recovered even when endogenous RBC ascorbate was below the detection threshold (25 nM). Twenty microliters of whole blood or 10 μl of packed RBCs was sufficient for assay. RBC ascorbate was stable for 24 h from whole-blood samples at 4 °C. Processed, stored samples were stable for >1 month at −80 °C. Unlike other tissues, ascorbate concentrations in human and mouse RBCs were linear in relation to plasma concentrations (R = 0.8 and 0.9, respectively). In healthy humans, RBC ascorbate concentrations were 9–57 μM, corresponding to ascorbate plasma concentrations of 15–90 μM. Mouse data were similar. In human blood stored as if for transfusion, initial RBC ascorbate concentrations varied approximately sevenfold and decreased 50% after 6 weeks of storage under clinical conditions. With this assay, it becomes possible for the first time to characterize ascorbate function in relation to endogenous concentrations in RBCs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ab.2012.04.014

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 39

Metadata

Authors
Li, H., Tu, H., Wang, Y., & Levine, M.
Venue
Analytical Biochemistry
Publisher
Elsevier BV
Published
2012-07
Volume
426
Issue
2
Pages
109-117
ISSN
0003-2697 (ISSN-L)
OpenAlex
W2005358532
Cited by
39
References
8
FWCI
2.63
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vitamin C in mouse and human red blood cells: An HPLC assay. https://app.cochat.ai/papers/10.1016/j.ab.2012.04.014
The paper
Li, H., Tu, H., Wang, Y., & Levine, M. (2012). Vitamin C in mouse and human red blood cells: An HPLC assay. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2012.04.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.