Simultaneous monitoring of inorganic cations, amines and amino acids in human sweat by capillary electrophoresis
Open accessThe DOI matches its Crossref record.
Abstract
The determination of cationic constituents of sweat is widely recognized as a difficult analytical task due to its complex composition and minute sample volumes available for the individual analysis. Capillary electrophoresis (CE) has been evaluated as a simple routine method to measure sweat metal cations, biogenic amines, and amino acids using a sampling procedure previously developed in one of collaborative teams. The carrier electrolyte, which consisted of 10 mM 4-methylbenzylamine, 6.5 mM alpha-hydroxyisobutyric acid, and 2 mM 18-crown-6 at pH 4.25, allowed the separation of five cations (NH(4)(+), K(+), Ca(2+), Na(+), Mg(2+)) and four amino acids (ornithine, histidine, lysine, arginine) to be completed in about 13 min with a positive polarity of the applied voltage (30 kV). By increasing the sample volume (due to employing hydrodynamic instead of hydrostatic injection mode), it was also possible to detect indirect UV signals of Zn(2+), diethanolamine, and trithanolamine. Sweat samples were collected from the fingers and forearms of three healthy male volunteers and analyzed by CE. A good repeatability and reproducibility of peak area responses based on five intraday and three inter-day assays (average %R.S.D. less than 3.5 and 2.5, respectively) were obtained. The limits of detection were in the range of 3.2-5.8 microM for alkali and alkaline-earth cations (hydrostatic injection) and 0.27-0.79 microM for other target analytes (hydrodynamic injection). The analytical results for particular analytes were found to vary, depending on the sampling spot and individual, but in general correspond well to clinical concentration ranges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Penetration of nanoparticles and nanomaterials in the skin: Fiction or reality?
Baroli, B. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21817 · Cited by 372
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“regulators such as exercise [187], [190], [191].”
Noninvasive monitoring of plasma l-dopa concentrations using sweat samples in Parkinson's disease
Tsunoda, M., Hirayama, M., Tsuda, T., & Ohno, K. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.12.032 · Cited by 49
Self-citation
Metadata
- Authors
- Hirokawa, T., Okamoto, H., Gosyo, Y., Tsuda, T., & Timerbaev, A. R.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2007-01
- Volume
- 581
- Issue
- 1
- Pages
- 83-88
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2038188731
- Cited by
- 63
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous monitoring of inorganic cations, amines and amino acids in human sweat by capillary electrophoresis. https://app.cochat.ai/papers/10.1016/j.aca.2006.07.077
- The paper
- Hirokawa, T., Okamoto, H., Gosyo, Y., Tsuda, T., & Timerbaev, A. R. (2007). Simultaneous monitoring of inorganic cations, amines and amino acids in human sweat by capillary electrophoresis. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2006.07.077
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.