Cited by 234Analytical chemistry methods developmentAnalytical Chemistry and ChromatographyPesticide Residue Analysis and Safety

Dispersive liquid–liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants

Farajzadeh, Mir Ali, Bahram, Morteza, Jönsson, Jan Åke·2007·Analytica Chimica Acta

Abstract

Dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography-diode array detection (HPLC-DAD) was presented for extraction and determination of Irganox 1010, Irganox 1076 and Irgafos 168 (antioxidants) in aqueous samples. Carbon tetrachloride at microliter volume level and acetonitrile were used as extraction and dispersive solvents, respectively. The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microL level. Limit of detection for analytes is between 3 and 7 ng mL(-1). One variable at a time optimization and response surface modeling were used to obtain optimum conditions for microextraction procedure and nearly same experimental conditions were obtained using both optimization methods. Recoveries in the ranges 78-86% and 84-110% were obtained by one variable at a time and response surface modeling, respectively. Using tap water and packed water as matrices do not show any detrimental effect on the extraction recoveries and enrichment factors of analytes.

Integrity signals

Registry

Crossref · 10.1016/j.aca.2007.03.040

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In comparison of sample-preparation techniques for antioxidants, LLE provided lower enrichment factors and higher solvent consumption, whereas SPE gave higher enrichment factors but was also more time consuming.

    “LLE provided lower enrichment factors and higher solvent consumption, whereas SPE gave higher enrichment factors but was also more time consuming.”
  • When SPE was compared with DLLME in terms of consumption of organic solvents, DLLME was better.

    “When SPE was compared with DLLME in terms of consumption of organic solvents, it was clear that DLLME was better.”
  • Endocrine disrupters, antioxidants, PAHs and other organic compounds of different natures have been analyzed by DLLME, IL-DLLME and DLLME-SFO.

    “Endocrine disrupters [10,18,57,59,80-83], antioxidants [62,84], PAHs [9,11,66,67,85,86] and other organic compounds of different natures [7,8,63, 87-104] have been analyzed by DLLME, IL-DLLME and DLLME-SFO.”
  • For DLLME of antioxidants, enrichment factors about 200 and recoveries of nearly 100% were attained.

    “Enrichment factors about 200 and recoveries of nearly 100% were attained in this study.”
  • Efficient experimental design methodologies have also been carried out for extraction parameter optimization in some works in Table 4, but to a lesser extent.

    “however, efficient experimental design methodologies have also been carried out, but to a lesser extent [10,62,63,84,90,97].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Farajzadeh, M. A., Bahram, M., & Jönsson, J. Å.
Affiliations
  • Urmia University (IR)
  • Lund University (SE)
Corresponding author
Jönsson, Jan Åke
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2007-05
Volume
591
Issue
1
Pages
69-79
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2087026944
Cited by
234
References
1
Citations by year
2026: 1 · 2025: 2 · 2024: 5 · 2023: 2 · 2022: 2 · 2020: 8 · 2019: 4 · 2018: 9 · 2017: 8 · 2016: 13 · 2015: 9 · 2014: 19 · 2013: 11 · 2012: 21
FWCI
33.41
Type
journal article
Language
en
Open access
closed
Locations
  • Analytica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
Keywords
dispersive liquid-liquid microextraction, antioxidants, Irganox 1010, Irganox 1076, Irgafos 168, HPLC-DAD, carbon tetrachloride, acetonitrile, response surface optimization, tap water, bottled water, aqueous sample

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review