CoChat

Coacervative extraction of Ochratoxin A in wines prior to liquid chromatography/fluorescence determination

Open access
García-Fonseca, Sergio, Ballesteros-Gómez, Ana, Rubio, Soledad, Pérez-Bendito, Dolores · 2008 · Analytica Chimica Acta
Cited by 45

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Coacervates made up of reverse micelles of decanoic acid were assessed as a new strategy for the simplification of wine sample treatment in the determination of Ochratoxin A (OTA). Simultaneous extraction/concentration of this contaminant was based on both hydrophobic and hydrogen bond OTA:coacervate interactions. Parameters affecting extraction efficiency and concentration factors were studied. Concentrations of decanoic acid and tetrahydrofuran (THF) were the most influential parameters, being 0.5% of acid and 5% of THF the selected ones. The procedure was very robust, so that the extractions were not influenced by the pH and the nature or concentration of matrix components. OTA recoveries from different types of wines (white, rosé and red) ranged between 85 and 100% and the actual concentration factors varied from 105 to 125 for sample volumes of 15 mL. The detection limits for OTA, after liquid chromatography/fluorimetry (LC/FL) analysis of the coacervate (20 microL), were 4.5 ng L(-1) in white and rosé wines and 15 ng L(-1) in red wines, values which were far below the threshold limit established for OTA by EU directives (2.0 microg L(-1)). No clean-up of the extracts was required for any of the samples analysed. The overall sample treatment took about 15-20 min and several samples could be simultaneously treated using conventional lab equipment. The precision of the method, expressed as relative standard deviation, was about 5%. The approach developed was successfully applied to the determination of OTA in different wine samples from the South of Spain. The concentrations found ranged between 0.015 and 0.091 microg L(-1).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.aca.2007.11.002

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 45

Metadata

Authors
García-Fonseca, S., Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D.
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2008-06
Volume
617
Issue
1-2
Pages
3-10
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2025034679
Cited by
45
References
2
FWCI
2.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coacervative extraction of Ochratoxin A in wines prior to liquid chromatography/fluorescence determination. https://app.cochat.ai/papers/10.1016/j.aca.2007.11.002
The paper
García-Fonseca, S., Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D. (2008). Coacervative extraction of Ochratoxin A in wines prior to liquid chromatography/fluorescence determination. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2007.11.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.