Recent trends in microdialysis sampling integrated with conventional and microanalytical systems for monitoring biological events: A review
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microdialysis (MD) is a sampling technique that can be employed to monitor biological events both in vivo and in vitro. When it is coupled to an analytical system, microdialysis can provide near realtime information on the time-dependent concentration changes of analytes in the extracellular space or other aqueous environments. Online systems for the analysis of microdialysis samples enable fast, selective and sensitive analysis while preserving the temporal information. Analytical methods employed for online analysis include liquid chromatography (LC), capillary (CE) and microchip electrophoresis and flow-through biosensor devices. This review article provides an overview of microdialysis sampling and online analysis systems with emphasis on in vivo analysis. Factors that affect the frequency of analysis and, hence, the temporal resolution of these systems are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo calibration of microdialysis probes for exogenous compounds
Menacherry, S., Hubert, W., & Justice, J. B. (1992) · Analytical Chemistry · doi:10.1021/ac00030a003 · Cited by 217 · cited 3×
“If a flow rate of 100nLmin−1 is employed, the relative recovery approaches 100% [37].”
Cited by
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Problems with measuring peripheral oxytocin: can the data on oxytocin and human behavior be trusted?
McCullough, M. E., Churchland, P. S., & Mendez, A. J. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.04.018 · Cited by 416
In Vivo Analysis with Electrochemical Sensors and Biosensors
Xiao, T., Wu, F., Hao, J., Zhang, M., Yu, P., & Mao, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04308 · Cited by 190
Zhang, M., Yu, P., & Mao, L. (2012) · Accounts of Chemical Research · doi:10.1021/ar200196h · Cited by 176
Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats
Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.016 · Cited by 33
“Microdialysis sampling is a well-established in vivo collection method [21,22].”
Metadata
- Authors
- Nandi, P., & Lunte, S. M.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2009-09
- Volume
- 651
- Issue
- 1
- Pages
- 1-14
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2071501745
- Cited by
- 220
- References
- 1
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.