Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats
Open accessAbstract
The level at which implanted sensors and sampling devices maintain their calibration is an important research area. In this work, microdialysis probes with identical geometry and different membranes, polycarbonate/polyether (PC) or polyethersulfone (PES), were used with internal standards (Vitamin B(12) (MW 1355), antipyrine (MW 188) and 2-deoxyglucose (2-DG, MW 164)) and endogenous glucose to investigate changes in their long-term calibration after implantation into the subcutaneous space of Sprague-Dawley rats. Histological analysis confirmed an inflammatory response to the microdialysis probes and the presence of a collagen capsule. The membrane extraction efficiency (percentage delivered to the tissue space) for antipyrine and 2-DG was not altered throughout the implant lifetime for either PC- or PES membranes. Yet, Vitamin B(12) extraction efficiency and collected glucose concentrations decreased during the implant lifetime. Antipyrine was administered i.v. and its concentrations obtained in both PC- and PES-membrane probes were significantly reduced between the implant day and seven (PC) or 10 (PES) days post-implantation suggesting that solute supply is critical for in vivo extraction efficiency. For the low molecular weight solutes such as antipyrine and glucose, localized delivery is not affected by the foreign body reaction, but recovery is significantly reduced. For Vitamin B(12), a larger solute, the fibrotic capsule formed around the probe significantly restricts diffusion from the implanted microdialysis probes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Microdialysis avoids direct sensor implantation, but in vivo glucose recovery is erratic because of the foreign body response.
“Microdialysis avoids direct implantation of a sensor but the glucose measurement (i.e., recovery) remains erratic in vivo due to the foreign body response.19,24–25”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [25]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Theory and Practice of Histological Techniques
Bancroft, J. D., & Gamble, M. (1990) · Cited by 6,986 · see citing works
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1× · see citing works
“All implanted sensors and/or devices initiate an immune response [4,5].”
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · see citing works
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507 · see citing works
Theory and Practice of Histological Techniques
MacSween, R. N. M. (1977) · Journal of Clinical Pathology · doi:10.1136/jcp.30.11.1089-a · Cited by 1,035 · see citing works
Localization of the primary metabolic block produced by 2-deoxyglucose
Wick, A. N., Drury, D. R., Nakada, H. I., Wolfe, J. B., Britton, B., & Grabowski, R. (1957) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)64988-9 · Cited by 780 · see citing works
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., von Recum, H. A., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 552 · see citing works
Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro
Bungay, P. M., Morrison, P. F., & Dedrick, R. L. (1990) · Life Sciences · doi:10.1016/0024-3205(90)90043-q · Cited by 507 · see citing works
The foreign body reaction: A chronic inflammatory response
Coleman, D. L., King, R. N., & Andrade, J. D. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080503 · Cited by 289 · see citing works
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268 · see citing works
Long-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Nandi, P., & Lunte, S. M. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.064 · Cited by 220 · see citing works
In vivo glucose monitoring: the clinical reality and the promise
Pickup, J. C., Hussain, F., Evans, N. D., & Sachedina, N. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.016 · Cited by 203 · see citing works
Koschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181 · see citing works
Bungay, P. M., Newton‐Vinson, P., Isele, W., Garris, P. A., & Justice, J. B. (2003) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2003.01904.x · Cited by 173 · see citing works
Reduced foreign body response at nitric oxide-releasing subcutaneous implants
Hetrick, E. M., Prichard, H. L., Klitzman, B., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.036 · Cited by 158 · see citing works
In Vivo Chemical Sensors: Tackling Biocompatibility
Frost, M. C., & Meyerhoff, M. E. (2006) · Analytical Chemistry · doi:10.1021/ac069475k · Cited by 145 · see citing works
Methods and issues in microdialysis calibration
Stenken, J. A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00598-4 · Cited by 129 · see citing works
Self-citationBiocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126 · see citing works
Wisniewski, N., Klitzman, B. M., Miller, B., & Reichert, W. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4 · Cited by 120 · see citing works
Protein interactions with subcutaneously implanted biosensors
Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.033 · Cited by 117 · see citing works
[Measuring EEG complexity for studying the state of mental load].
Liu, J., He, T., Zheng, C., & Huang, Y. (1997) · PubMed · Cited by 91 · see citing works
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87 · see citing works
A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation
Ward, W. K., Jansen, L. B., Anderson, E., Reach, G., Klein, J.-C., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00268-8 · Cited by 81 · see citing works
Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?
Rebrin, K., Fischer, U., von Dorsche, H. H., von Woetke, T., Abel, P., & Brunstein, E. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90033-h · Cited by 81 · see citing works
Iyer, S. S., Barr, W. H., & Karnes, H. T. (2006) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.493 · Cited by 73 · see citing works
Feasibility of Continuous Long-Term Glucose Monitoring from a Subcutaneous Glucose Sensor in Humans
Gilligan, B. C., Shults, M., Rhodes, R. K., Jacobs, P. G., Brauker, J. H., Pintar, T. J., & Updike, S. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198089 · Cited by 71 · see citing works
Ju, Y. M., Yu, B., Koob, T. J., Moussy, Y., & Moussy, F. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31756 · Cited by 70 · see citing works
Continuous Glucose Monitoring: An Overview of Its Development
Skyler, J. S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0045 · Cited by 63 · see citing works
Yokel, R. A., Allen, D. D., Burgio, D. E., et al. (1992) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/1056-8719(92)90034-x · Cited by 59 · see citing works
In Vitro Characterization of Microdialysis Sampling of Macromolecules
Schutte, R. J., Oshodi, S. A., & Reichert, W. M. (2004) · Analytical Chemistry · doi:10.1021/ac0493626 · Cited by 57 · see citing works
Ju, Y. M., Yu, B., West, L., Moussy, Y., & Moussy, F. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32400 · Cited by 52 · see citing works
Deguchi, Y., Terasaki, T., KAWASAKI, S., et al. (1991) · Journal of Pharmacobio-Dynamics · doi:10.1248/bpb1978.14.483 · Cited by 49 · see citing works
Study of the effects of tissue reactions on the function of implanted glucose sensors
Dungel, P., Long, N., Yu, B., Moussy, Y., & Moussy, F. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31593 · Cited by 47 · see citing works
Winet, H., & Bao, J. Y. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4 · Cited by 44 · see citing works
Passivating protein coatings for implantable glucose sensors: Evaluation of protein retention
Geelhood, S., Horbett, T. A., Ward, W. K., et al. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30660 · Cited by 42 · see citing works
Ward, W. K., Wood, M. D., Casey, H. M., Quinn, M. J., & Federiuk, I. F. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731320 · Cited by 39 · see citing works
Groth, L., Jørgensen, A., & Serup, J. V. (1998) · Skin Pharmacology and Physiology · doi:10.1159/000029818 · Cited by 29 · see citing works
Wang, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2007) · Analytical Chemistry · doi:10.1021/ac061503b · Cited by 26 · see citing works
Self-citationMathy, F., Denet, A.-R., Vroman, B., et al. (2003) · Skin Pharmacology and Physiology · doi:10.1159/000068290 · Cited by 24 · see citing works
Ex Vivo Continuous Glucose Monitoring With Microdialysis Technique: The Example of GlucoDay
Ricci, F., Moscone, D., & Palleschi, G. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912535 · Cited by 23 · see citing works
Tissue response to subcutaneous implantation of glucose-oxidase-based glucose sensors in rats
Henninger, N., Woderer, S., Klötzer, H.-M., Staib, A., Gillen, R. C., Li, L., Yu, X., Gretz, N., Kraenzlin, B., & Pill, J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.03.016 · Cited by 18 · see citing works
Mou, X., & Stenken, J. A. (2006) · Analytical Chemistry · doi:10.1021/ac061124i · Cited by 7 · see citing works
Self-citationHaraldsson, B. S., & Rippe, B. (1991) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1991.tb09228.x · Cited by 2 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- [1]Cunningham DD Stenken JA In vivo glucose sensors 2010 Hoboken, NJ John Wiley & Sons
- [21]Westerink BHC Cremers TIFH Handbook of microdialysis sampling: Methods, applications, and clinical aspects 2007 Amsterdam Academic Press
- [35]Sharkawy AA Klitzman B Truskey GA Reichert WM Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times J. Biomed Mater Res 1998 40 598 605 9599036
Cited by
Sorted by citations
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Increased<i>In Vivo</i>Glucose Recovery via Nitric Oxide Release
Nichols, S. P., Le, N. N., Klitzman, B., & Schoenfisch, M. H. (2011) · Analytical Chemistry · doi:10.1021/ac103070t · Cited by 26 · see citing works
- Authors
- Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A.
- Affiliations
- Rensselaer Polytechnic Institute (US)
- Albany Medical College (US)
- University of Arkansas at Fayetteville (US)
- Corresponding author
- Stenken, Julie A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 31
- Issue
- 16
- Pages
- 4530-4539
- ISSN
- 0142-9612 (ISSN-L)
- PMC
- PMC3547652
- OpenAlex
- W2084752937
- Cited by
- 33
- References
- 45
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2019: 2 · 2018: 2 · 2016: 1 · 2015: 4 · 2013: 7 · 2012: 2
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (EB001441)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Keywords
- polycarbonate membranes, polyethersulfone membranes, foreign body reaction, collagen capsule, extraction efficiency, solute diffusion, antipyrine, 2-deoxyglucose, vitamin B12
- MeSH terms
- Animals, Antipyrine, Calibration, Deoxyglucose, Glucose, Injections, Subcutaneous, Polymers, Vitamin B 12, Biosensing Techniques, Rats, Sprague-Dawley, Microdialysis, Implants, Experimental, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review