Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats

Open access
Mou, Xiaodun, Lennartz, Michelle R., Loegering, Daniel J., Stenken, Julie A.·2010·Biomaterials

Abstract

The level at which implanted sensors and sampling devices maintain their calibration is an important research area. In this work, microdialysis probes with identical geometry and different membranes, polycarbonate/polyether (PC) or polyethersulfone (PES), were used with internal standards (Vitamin B(12) (MW 1355), antipyrine (MW 188) and 2-deoxyglucose (2-DG, MW 164)) and endogenous glucose to investigate changes in their long-term calibration after implantation into the subcutaneous space of Sprague-Dawley rats. Histological analysis confirmed an inflammatory response to the microdialysis probes and the presence of a collagen capsule. The membrane extraction efficiency (percentage delivered to the tissue space) for antipyrine and 2-DG was not altered throughout the implant lifetime for either PC- or PES membranes. Yet, Vitamin B(12) extraction efficiency and collected glucose concentrations decreased during the implant lifetime. Antipyrine was administered i.v. and its concentrations obtained in both PC- and PES-membrane probes were significantly reduced between the implant day and seven (PC) or 10 (PES) days post-implantation suggesting that solute supply is critical for in vivo extraction efficiency. For the low molecular weight solutes such as antipyrine and glucose, localized delivery is not affected by the foreign body reaction, but recovery is significantly reduced. For Vitamin B(12), a larger solute, the fibrotic capsule formed around the probe significantly restricts diffusion from the implanted microdialysis probes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2010.02.016

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Microdialysis avoids direct sensor implantation, but in vivo glucose recovery is erratic because of the foreign body response.

    “Microdialysis avoids direct implantation of a sensor but the glucose measurement (i.e., recovery) remains erratic in vivo due to the foreign body response.19,24–25”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. [1]Cunningham DD Stenken JA In vivo glucose sensors 2010 Hoboken, NJ John Wiley & Sons
  2. [21]Westerink BHC Cremers TIFH Handbook of microdialysis sampling: Methods, applications, and clinical aspects 2007 Amsterdam Academic Press
  3. [35]Sharkawy AA Klitzman B Truskey GA Reichert WM Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times J. Biomed Mater Res 1998 40 598 605 9599036

Cited by

Sorted by citations

Authors
Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A.
Affiliations
  • Rensselaer Polytechnic Institute (US)
  • Albany Medical College (US)
  • University of Arkansas at Fayetteville (US)
Corresponding author
Stenken, Julie A.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2010-06
Volume
31
Issue
16
Pages
4530-4539
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2084752937
Cited by
33
References
45
Citations by year
2026: 3 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2019: 2 · 2018: 2 · 2016: 1 · 2015: 4 · 2013: 7 · 2012: 2
FWCI
1.94
Type
journal article
Language
en
Open access
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institutes of Health (EB001441)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
polycarbonate membranes, polyethersulfone membranes, foreign body reaction, collagen capsule, extraction efficiency, solute diffusion, antipyrine, 2-deoxyglucose, vitamin B12
MeSH terms
Animals, Antipyrine, Calibration, Deoxyglucose, Glucose, Injections, Subcutaneous, Polymers, Vitamin B 12, Biosensing Techniques, Rats, Sprague-Dawley, Microdialysis, Implants, Experimental, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review