Determination of halides using Ag nanoparticles-modified disposable electrodes. A first approach to a wearable sensor for quantification of chloride ions
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This work reports a simple voltammetric method for the determination of chloride, bromide, and iodide ions using screen-printed carbon electrodes modified with silver nanoparticles electrochemically deposited on the working electrode surface. UV/Vis absorption spectroelectrochemistry was used to study the electrodeposition of silver nanoparticles on the working carbon electrode on PET or Gore-Tex ® supports, and their subsequent oxidation in the presence of halide ions. The main figures of merit of the developed sensors, such as reproducibility and detection limit, have been calculated. Reproducibility values of 2.22%, 2.83% and 3.23% were obtained for chloride, bromide and iodide determinations, respectively. Additionally, the lowest detected amount of chloride, bromide and iodide ions were 3.0·10 −6 M, 5.0·10 −6 M and 5.0·10 −6 M, respectively. Taking into account the relevance of the determination of chloride ion concentration in sweat, the voltammetric method for the determination of halides has been successfully transferred to a Gore-Tex ® support to build a first approach to a wearable sensor that facilitates the quantification of this ion in sweat samples. The Gore-Tex ® sensor provides a good reproducibility (RSD = 1.61%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat
Morgan, R. M., Patterson, M. J., & Nimmo, M. A. (2004) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2004.01305.x · Cited by 192
Cited by
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Ye, H., Cheng, J., & Yu, K. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.10.056 · Cited by 191
Li, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119
Metadata
- Authors
- Bujes-Garrido, J., Izquierdo-Bote, D., Heras, A., Colina, A., & Arcos-Martínez, M. J.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 1012
- Pages
- 42-48
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2791247850
- Cited by
- 59
- References
- 3
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.