Cited by 443Advanced Sensor and Energy Harvesting MaterialsElectrochemical sensors and biosensorsAnalytical Chemistry and Sensors

A wearable multisensing patch for continuous sweat monitoring

Open access
Anastasova, Salzitsa, Crewther, Blair, Bembnowicz, Pawel, Curto, Vincenzo, Ip, Henry MD, Rosa, Bruno, Yang, Guang-Zhong·2017·Biosensors and Bioelectronics

Abstract

In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the platform is designed such that continuous flow of sweat can pass through an array of flexible microneedle type of sensors (50µm diameter) incorporated in a microfluidic channel. Potentiometric sodium ion sensors were developed using a polyvinyl chloride (PVC) functional membrane deposited on an electrochemically deposited internal layer of Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer. The pH sensing layer is based on a highly sensitive membrane of iridium oxide (IrOx). The amperometric-based lactate sensor consists of doped enzymes deposited on top of a semipermeable copolymer membrane and outer polyurethane layers. Real-time data were collected from human subjects during cycle ergometry and treadmill running. A detailed comparison of sodium, lactate and cortisol from saliva is reported, demonstrating the potential of the multi-sensing platform for tracking these outcomes. In summary, a fully integrated sensor for continuous, simultaneous and selective measurement of sweat metabolites, electrolytes and temperature was achieved using a flexible microfluidic platform. This system can also transmit information wirelessly for ease of collection and storage, with the potential for real-time data analytics.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2016.09.038

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z.
Affiliations
  • Imperial College London (GB)
  • Instytut Sportu (PL)
Corresponding author
Anastasova, Salzitsa
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2017-07
Volume
93
Pages
139-145
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2521475794
Cited by
443
References
28
Citations by year
2026: 31 · 2025: 39 · 2024: 42 · 2023: 43 · 2022: 55 · 2021: 68 · 2020: 58 · 2019: 57 · 2018: 42 · 2017: 8
FWCI
17.17
Type
journal article
Language
en
Update notices
erratum (2017-08-15)
Open access
Locations
  • Biosensors and Bioelectronics (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Spiral (Imperial College London) (submittedVersion, cc-by-nc-nd)
  • Spiral (Imperial College London) (submittedVersion, other-oa)
Funders
  • Elite Sport Performance Research in Training with Pervasive Sensing Programme (EP/H009744/1)
  • Engineering and Physical Sciences Research Council
  • UK Sports Council
  • Smart Sensing for Surgery Project (EP/L014149/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
wearable sensors, sweat monitoring, flexible microfluidics, lactate sensing, sodium ion detection, pH sensing, PEDOT, microneedle sensors, cortisol, exercise monitoring, wireless data transmission, human performance monitoring
MeSH terms
Electrolytes, Humans, Hydrogen-Ion Concentration, Iridium, Polymers, Polyvinyl Chloride, Sweat, Biosensing Techniques, Bridged Bicyclo Compounds, Heterocyclic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review