CoChat

A deep eutectic solvent modified magnetic β-cyclodextrin particle for solid-phase extraction of trypsin

Xu, Fangting, Wang, Yuzhi, Liu, Ziwei, Wei, Xiaoxiao, Chen, Jing, He, Xiyan, Li, Heqiong, Zhou, Yigang · 2020 · Analytica Chimica Acta
Cited by 39

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

An environmentally friendly deep eutectic solvent (DES) composed of trifluoroacetamide and benzyltrimethylammonium chloride modified β-cyclodextrin (CD) grafted magnetic beads (MB-NH2@CD@DES) were synthesized for the first time and applied to the solid-phase extraction of trypsin. Among the five trypsin extractants prepared in this work (MB, MB-NH2, MB-NH2@CD, MB-NH2@DES, MB-NH2@CD@DES), the extractant MB-NH2@CD@DES with higher extraction capacity for trypsin was selected as final extractant. The extraction capacity of MB-NH2@CD@DES for trypsin can reach up to 549.87 mg⋅g-1 under the optimized conditions. The Langmuir adsorption equilibrium was found fitted better with equilibrium relation between MB-NH2@CD@DES and trypsin than Freundlich adsorption equilibrium. And a superior extraction for trypsin was verified by comparing the extraction capacity of MB-NH2@CD@DES for trypsin and four other common proteins. Compared with some reported trypsin extractants, the MB-NH2@CD@DES had a shorter extraction process, higher extraction capacity, more convenient operation of separation, a safer and more environmentally friendly synthesis process. With the optimized eluent, a great elution rate (74.32%) of trypsin was achieved. The absolute recovery of trypsin in trypsin standard solution was calculated to be 16.8%. And the extraction capacity of MB-NH2@CD@DES toward trypsin still maintained well after ten times recycling and reuse. The detection limit (LOD) and quantitative limit (LOQ) were 0.072 mg⋅mL-1 and 0.240 mg⋅mL-1 respectively. By sodium dodecyl sulfate polyacrylamide gel electrophoresis experiment, the extraction ability of MB-NH2@CD@DES to trypsin from real sample was fully demonstrated. All above results showed the potential of fabricated MB-NH2@CD@DES as a superior extractant for trypsin from real complex samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.aca.2020.09.005

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Xu, F., Wang, Y., Liu, Z., Wei, X., Chen, J., He, X., Li, H., & Zhou, Y.
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2020-11
Volume
1137
Pages
125-135
ISSN
0003-2670 (ISSN-L)
OpenAlex
W3083799779
Cited by
39
References
7
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.