A Cascaded Deep Learning–Based Artificial Intelligence Algorithm for Automated Lesion Detection and Classification on Biparametric Prostate Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Rationale and objectives: Prostate MRI improves detection of clinically significant prostate cancer; however, its diagnostic performance has wide variation. Artificial intelligence (AI) has the potential to assist radiologists in the detection and classification of prostatic lesions. Herein, we aimed to develop and test a cascaded deep learning detection and classification system trained on biparametric prostate MRI using PI-RADS for assisting radiologists during prostate MRI read out. Materials and Methods: T2-weighted, diffusion-weighted (ADC maps, high b value DWI) MRI scans obtained at 3 Tesla from two institutions (n = 1043 in-house and n = 347 Prostate-X, respectively) acquired between 2015 to 2019 were used for model training, validation, testing. All scans were retrospectively reevaluated by one radiologist. Suspicious lesions were contoured and assigned a PI-RADS category. A 3D U-Net-based deep neural network was used to train an algorithm for automated detection and segmentation of prostate MRI lesions. Two 3D residual neural network were used for a 4-class classification task to predict PI-RADS categories 2 to 5 and BPH. Training and validation used 89% (n = 1290 scans) of the data using 5 fold cross-validation, the remaining 11% (n = 150 scans) were used for independent testing. Algorithm performance at lesion level was assessed using sensitivities, positive predictive values (PPV), false discovery rates (FDR), classification accuracy, Dice similarity coefficient (DSC). Additional analysis was conducted to compare AI algorithm's lesion detection performance with targeted biopsy results. Results: Median age was 66 years (IQR = 60-71), PSA 6.7 ng/ml (IQR = 4.7-9.9) from in-house cohort. In the independent test set, algorithm correctly detected 111 of 198 lesions leading to 56.1% (49.3%-62.6%) sensitivity. PPV was 62.7% (95% CI 54.7%-70.7%) with FDR of 37.3% (95% CI 29.3%-45.3%). Of 79 true positive lesions, 82.3% were tumor positive at targeted biopsy, whereas of 57 false negative lesions, 50.9% were benign at targeted biopsy. Median DSC for lesion segmentation was 0.359. Overall PI-RADS classification accuracy was 30.8% (95% CI 24.6%-37.8%). Conclusion: Our cascaded U-Net, residual network architecture can detect, classify cancer suspicious lesions at prostate MRI with good detection, reasonable classification performance metrics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
Çiçek, Ö., Abdulkadir, A., Lienkamp, S. S., Brox, T., & Ronneberger, O. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_49 · Cited by 7,945
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Turkbey, B., Rosenkrantz, A. B., Haider, M. A., Padhani, A. R., Villeirs, G., Macura, K. J., Tempany, C. M., Choyke, P. L., Cornud, F., Margolis, D. J., et al. (2019) · European Urology · doi:10.1016/j.eururo.2019.02.033 · Cited by 2,544
Self-citation
Cited by
Sunoqrot, M. R. S., Saha, A., Hosseinzadeh, M., Elschot, M., & Huisman, H. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00288-8 · Cited by 76
“Deep learning AI models are being incorporated in products that provide human interface software that aims to help improve workflow and reduce diagnostic performance variability [45, 47, 60, 71].”
BackgroundMethodMachine learning in prostate MRI for prostate cancer: current status and future opportunities
Li, H., Lee, C. H., Chia, D., Lin, Z., Huang, W., & Tan, C. H. (2022) · Diagnostics · doi:10.3390/diagnostics12020289 · Cited by 74
“[100] proposed a cascaded DL model for lesion detection and scoring on bpMRI.”
MethodSimon, B. D., Ozyoruk, K. B., Gelikman, D. G., Harmon, S. A., & Türkbey, B. (2024) · Diagnostic and Interventional Radiology · doi:10.4274/dir.2024.242631 · Cited by 73
Self-citationBelue, M. J., Harmon, S. A., Lay, N. S., Daryanani, A., Phelps, T. E., Choyke, P. L., & Turkbey, B. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2022.05.022 · Cited by 27
Self-citation
Metadata
- Authors
- Mehralivand, S., Yang, D., Harmon, S. A., Xu, D., Xu, Z., Roth, H., Masoudi, S., Sanford, T. H., Kesani, D., Lay, N. S., Merino, M. J., Wood, B. J., Pinto, P. A., Choyke, P. L., & Turkbey, B.
- Venue
- Academic Radiology
- Publisher
- Elsevier BV
- Published
- 2022-08
- Volume
- 29
- Issue
- 8
- Pages
- 1159-1168
- ISSN
- 1076-6332 (ISSN-L)
- OpenAlex
- W3202670079
- Cited by
- 73
- References
- 4
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Cascaded Deep Learning–Based Artificial Intelligence Algorithm for Automated Lesion Detection and Classification on Biparametric Prostate Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1016/j.acra.2021.08.019
- The paper
- Mehralivand, S., Yang, D., Harmon, S. A., Xu, D., Xu, Z., Roth, H., Masoudi, S., Sanford, T. H., Kesani, D., Lay, N. S., Merino, M. J., Wood, B. J., Pinto, P. A., Choyke, P. L., & Turkbey, B. (2022). A Cascaded Deep Learning–Based Artificial Intelligence Algorithm for Automated Lesion Detection and Classification on Biparametric Prostate Magnetic Resonance Imaging. Academic Radiology. https://doi.org/10.1016/j.acra.2021.08.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.