The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Ultrahigh-strength titanium gyroid scaffolds manufactured by selective laser melting (SLM) for bone implant applications
Abstract
Abstract Commercially pure titanium (CP–Ti) gyroid scaffolds with interconnected pores and high porosities in the range of 68–73% and three different unit cell sizes of 2, 2.5, and 3 mm were manufactured by selective laser melting (SLM) for bone implant applications. The microstructure and mechanical properties of the scaffolds with different unit cell sizes and sample orientations were evaluated. The microstructure of as-built struts was dominated by massive martensite and the average microhardness of the struts was 2.27 GPa, which is ∼50% higher than that of dense cast CP–Ti. The elastic modulus and yield strength of the as-built scaffolds ranged from 1465 to 2676 MPa and from 44.9 to 56.5 MPa, respectively, values which are close to the elastic modulus of trabecular bone and presumably strong enough to bear the physiological loading of implants. The as-built scaffolds exhibited excellent ductility up to 50% strain and no sign of fracture up to 20–30% strain under compression. The dominant compressive response of the scaffolds was observed by formation of a plastic hinge which led to rotation of the struts about the plastic hinges followed by development of local shear bands in struts in the long plateau region. These SLM-manufactured gyroid CP–Ti scaffolds with significantly enhanced hardness and compressive strength exhibited an elastic modulus close to that of trabecular bone and offer a promising improvement on CP–Ti scaffolds for bone implant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
A study of the microstructural evolution during selective laser melting of Ti–6Al–4V
Thijs, L., Verhaeghe, F., Craeghs, T., Humbeeck, J. V., & Kruth, J.-P. (2010) · Acta Materialia · doi:10.1016/j.actamat.2010.02.004 · Cited by 2,929
Ashby, M., Evans, A., Fleck, N., Gibson, L., Hutchinson, J., Wadley, H., & Delale, F. (2001) · Applied Mechanics Reviews · doi:10.1115/1.1421119 · Cited by 2,694
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Self-citationXu, W., Brandt, M., Sun, S., Elambasseril, J., Liu, Q., Latham, K., Xia, K., & Qian, M. (2015) · Acta Materialia · doi:10.1016/j.actamat.2014.11.028 · Cited by 1,245
Self-citationGu, D., Hagedorn, Y.-C., Meiners, W., Meng, G., Batista, R. J. S., Wissenbach, K., & Poprawe, R. (2012) · Acta Materialia · doi:10.1016/j.actamat.2012.04.006 · Cited by 1,089
Formation and control of martensite in Ti-6Al-4V alloy produced by selective laser melting
Yang, J., Yu, H., Yin, J., Gao, M. X., Wang, Z., & Zeng, X. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.06.117 · Cited by 913
Bobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
Manufacture by selective laser melting and mechanical behavior of commercially pure titanium
Attar, H., Calin, M., Zhang, L. C., Scudino, S., & Eckert, J. (2014) · Materials Science and Engineering: A · doi:10.1016/j.msea.2013.11.038 · Cited by 744
Cited by
SLM lattice structures: Properties, performance, applications and challenges
Maconachie, T., Leary, M., Lozanovski, B., Zhang, X., Qian, M., Faruque, O., & Brandt, M. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.108137 · Cited by 1,497
Self-citationReview on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
Multifunctional Mechanical Metamaterials Based on Triply Periodic Minimal Surface Lattices
Al-Ketan, O., & Abu Al-Rub, R. K. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201900524 · Cited by 887
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
Yuan, L., Ding, S., & Wen, C. (2019) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.12.003 · Cited by 593
Self-citation
Metadata
- Authors
- Ataee, A., Li, Y., Brandt, M., & Wen, C.
- Venue
- Acta Materialia
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 158
- Pages
- 354-368
- ISSN
- 1359-6454 (ISSN-L)
- OpenAlex
- W2885940131
- Cited by
- 383
- References
- 65
- FWCI
- 20.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh-strength titanium gyroid scaffolds manufactured by selective laser melting (SLM) for bone implant applications. https://app.cochat.ai/papers/10.1016/j.actamat.2018.08.005
- The paper
- Ataee, A., Li, Y., Brandt, M., & Wen, C. (2018). Ultrahigh-strength titanium gyroid scaffolds manufactured by selective laser melting (SLM) for bone implant applications. Acta Materialia. https://doi.org/10.1016/j.actamat.2018.08.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.