The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Direct laser processing of a tantalum coating on titanium for bone replacement structures
Open accessAbstract
Recently, tantalum is gaining more attention as a new metallic biomaterial as it has been shown to be bioactive and biologically bond to the bone. However, relatively high cost of manufacture and inability to produce a modular all tantalum implant has limited'its widespread acceptance. In this study, we have successfully deposited Ta coating on Ti using Laser Engineered Net Shaping (LENS™) to enhance osseointegration properties. In vitro biocompatibility study, using human osteoblast cell line hFOB, showed excellent cellular adherence and growth with abundant extracellular matrix formation on Ta coating surface compare to Ti surface. Six times higher living cell density was observed on Ta coating than on Ti control surface during MMT assay. High surface energy and wettability of Ta surface were observed to contribute to its significantly better cell-materials interactions. Also, these dense Ta coatings do not suffer from low fatigue resistance due to the absence of porosity and sharp interface between the coating and the substrate, which is a major concern for porous coatings used for enhanced/early biological fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novel bioactive materials with different mechanical properties
Kokubo, T., Kim, H.-M., & Kawashita, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00044-9 · Cited by 1,914
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
Bobyn, J. D., Stackpool, G. J., Hacking, S. A., Tanzer, M., & Krygier, J. J. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b5.0810907 · Cited by 1,037
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Matsuno, H. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00275-1 · Cited by 828
Webb, K., Hlady, V., & Tresco, P. A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<422::aid-jbm12>3.0.co;2-k · Cited by 689
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
Self-citationLow stiffness porous Ti structures for load-bearing implants
Krishna, B. V., Bose, S., & Bandyopadhyay, A. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.03.008 · Cited by 441
Self-citationSurface modifications and cell–materials interactions with anodized Ti
DAS, K., BOSE, S., & BANDYOPADHYAY, A. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.12.003 · Cited by 324
Self-citationTissue response to porous tantalum acetabular cups
Bobyn, J., Toh, K.-K., Hacking, S. A., Tänzer, M., & Krygier, J. J. (1999) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(99)90062-1 · Cited by 281
Redey, S. A., Nardin, M., Bernache-Assolant, D., Rey, C., Delannoy, P., Sedel, L., & Marie, P. J. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000605)50:3<353::aid-jbm9>3.0.co;2-c · Cited by 240
Cited by
Svetlizky, D., Das, M., Zheng, B., Vyatskikh, A. L., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.020 · Cited by 1,371
Self-citationThijs, L., Montero Sistiaga, M. L., Wauthle, R., Xie, Q., Kruth, J.-P., & Van Humbeeck, J. (2013) · Acta Materialia · doi:10.1016/j.actamat.2013.04.036 · Cited by 672
Metallic Biomaterials: Current Challenges and Opportunities
Prasad, K., Bazaka, O., Chua, M., Rochford, M., Fedrick, L., Spoor, J., Symes, R., Tieppo, M., Collins, C., Cao, A., et al. (2017) · Materials · doi:10.3390/ma10080884 · Cited by 662
Additive manufacturing of functionally graded metallic materials using laser metal deposition
Yan, L., Chen, Y., & Liou, F. (2020) · Additive Manufacturing · doi:10.1016/j.addma.2019.100901 · Cited by 367
Laser-based directed energy deposition (DED-LB) of advanced materials
Svetlizky, D., Zheng, B., Vyatskikh, A., Das, M., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2022) · Materials Science and Engineering: A · doi:10.1016/j.msea.2022.142967 · Cited by 331
Self-citation
Metadata
- Authors
- Balla, V. K., Banerjee, S., Bose, S., & Bandyopadhyay, A.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 6
- Issue
- 6
- Pages
- 2329-2334
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2006563583
- Cited by
- 333
- References
- 15
- FWCI
- 14.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct laser processing of a tantalum coating on titanium for bone replacement structures. https://app.cochat.ai/papers/10.1016/j.actbio.2009.11.021
- The paper
- Balla, V. K., Banerjee, S., Bose, S., & Bandyopadhyay, A. (2010). Direct laser processing of a tantalum coating on titanium for bone replacement structures. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2009.11.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.