The DOI matches its Crossref record; 121 of the 121 references it cites were found in a registry or an index.
Review of titanium surface modification techniques and coatings for antibacterial applications
Abstract
Implanted biomaterials play a key role in the current success of orthopedic and dental procedures. Pure titanium and its alloys are the most commonly used materials for permanent implants in contact with bone. However, implant-related infections remain among the leading reasons for failure. The most critical pathogenic event in the development of infection on biomaterials is biofilm formation, which starts immediately after bacterial adhesion. In the last decade, numerous studies reported the ability of titanium surface modifications and coatings to minimize bacterial adhesion, inhibit biofilm formation and provide effective bacterial killing to protect implanted biomaterials. In the present review, the different strategies to prevent infection onto titanium surfaces are reported: surface modification and coatings by antibiotics, antimicrobial peptides, inorganic antibacterial metal elements and antibacterial polymers. STATEMENT OF SIGNIFICANCE: Implanted biomaterials play a key role in the current success of orthopedic and dental procedures. Pure titanium and its alloys are the most commonly used materials for permanent implants in contact with bone. Microbial infection is one of the main causes of implant failure. Currently, the global infection risk is 2-5% in orthopedic surgery. Numerous solutions exist to render titanium surfaces antibacterial. The LBPS team is an expert on the functionalization of titanium surfaces by using bioactive polymers to improve the biologiocal response. In this review, the different strategies to prevent infection are reported onto titanium and titanium alloy surfaces such as surface modification by antibiotics, antimicrobial peptides, inorganic antibacterial metal elements and antibacterial polymers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Titanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510
TiO2 Photocatalysis: A Historical Overview and Future Prospects
Hashimoto, K., Irie, H., & Fujishima, A. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.8269 · Cited by 3,367
Transfer of Large-Area Graphene Films for High-Performance Transparent Conductive Electrodes
Li, X., Zhu, Y., Cai, W., Borysiak, M., Han, B., Chen, D., Piner, R. D., Colombo, L., & Ruoff, R. S. (2009) · Nano Letters · doi:10.1021/nl902623y · Cited by 3,081
Treatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257
Fleming, A. (1929) · PubMed Central · Cited by 1,647
A review of the biomaterials technologies for infection-resistant surfaces
Campoccia, D., Montanaro, L., & Arciola, C. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.089 · Cited by 1,358
Photocatalytic disinfection using titanium dioxide: spectrum and mechanism of antimicrobial activity
Foster, H. A., Ditta, I. B., Varghese, S., & Steele, A. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3213-7 · Cited by 1,164
The significance of infection related to orthopedic devices and issues of antibiotic resistance
Campoccia, D., Montanaro, L., & Arciola, C. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.044 · Cited by 1,109
Plasma source ion-implantation technique for surface modification of materials
Conrad, J. R., Radtke, J. L., Dodd, R. A., Worzala, F. J., & Tran, N. C. (1987) · Journal of Applied Physics · doi:10.1063/1.339055 · Cited by 1,107
Arciola, C. R., Campoccia, D., Speziale, P., Montanaro, L., & Costerton, J. W. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.031 · Cited by 1,047
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
Antibacterial Coatings: Challenges, Perspectives, and Opportunities
Cloutier, M., Mantovani, D., & Rosei, F. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.002 · Cited by 813
Antibacterial nano-structured titania coating incorporated with silver nanoparticles
Zhao, L., Wang, H., Huo, K., Cui, L., Zhang, W., Ni, H., Zhang, Y., Wu, Z., & Chu, P. K. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.040 · Cited by 772
The relationship between the nanostructure of titanium surfaces and bacterial attachment
Puckett, S. D., Taylor, E., Raimondo, T., & Webster, T. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.081 · Cited by 683
Influence of engineered titania nanotubular surfaces on bone cells
Popat, K. C., Leoni, L., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.020 · Cited by 598
Chen, W., Liu, Y., Courtney, H. S., Bettenga, M., Agrawal, C. M., Bumgardner, J. D., & Ong, J. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.003 · Cited by 594
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Chua, P.-H., Neoh, K.-G., Kang, E.-T., & Wang, W. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.019 · Cited by 483
Peri-implant Inflammation Defined by the Implant-Abutment Interface
Broggini, N., McManus, L. M., Hermann, J. S., Medina, R., Schenk, R. K., Buser, D., & Cochran, D. L. (2006) · Journal of Dental Research · doi:10.1177/154405910608500515 · Cited by 480
Harris, L. G., Tosatti, S., Wieland, M., Textor, M., & Richards, R. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.033 · Cited by 393
Mei, S., Wang, H., Wang, W., Tong, L., Pan, H., Ruan, C., Ma, Q., Liu, M., Yang, H., Zhang, L., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.005 · Cited by 368
Kazemzadeh-Narbat, M., Kindrachuk, J., Duan, K., Jenssen, H., Hancock, R. E. W., & Wang, R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.035 · Cited by 343
Hardes, J., von Eiff, C., Streitbuerger, A., Balke, M., Budny, T., Henrichs, M. P., Hauschild, G., & Ahrens, H. (2010) · Journal of Surgical Oncology · doi:10.1002/jso.21498 · Cited by 337
Influence of surface modifications to titanium on antibacterial activity in vitro
Yoshinari, M., Oda, Y., Kato, T., & Okuda, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00392-6 · Cited by 331
A novel antibacterial titania coating: Metal ion toxicity and in vitro surface colonization
Heidenau, F., Mittelmeier, W., Detsch, R., Haenle, M., Stenzel, F., Ziegler, G., & Gollwitzer, H. (2005) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-005-4422-3 · Cited by 324
Mudunkotuwa, I. A., & Grassian, V. H. (2010) · Journal of the American Chemical Society · doi:10.1021/ja106091q · Cited by 297
Antimicrobial titanium/silver PVD coatings on titanium
Ewald, A., Glückermann, S. K., Thull, R., & Gbureck, U. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-22 · Cited by 281
Osteogenic activity and antibacterial effect of zinc ion implanted titanium
Jin, G., Cao, H., Qiao, Y., Meng, F., Zhu, H., & Liu, X. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.02.025 · Cited by 258
Titanium Oxide Antibacterial Surfaces in Biomedical Devices
Visai, L., De Nardo, L., Punta, C., Melone, L., Cigada, A., Imbriani, M., & Arciola, C. R. (2011) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000050 · Cited by 243
Diameter of titanium nanotubes influences anti-bacterial efficacy
Ercan, B., Taylor, E., Alpaslan, E., & Webster, T. J. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/29/295102 · Cited by 240
The Peri‐Implantitis: Implant Surfaces, Microstructure, and Physicochemical Aspects
Mouhyi, J., Dohan Ehrenfest, D. M., & Albrektsson, T. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2009.00244.x · Cited by 237
Plaque formation on surface modified dental implants: An in vitro study
Größner‐Schreiber, B., Griepentrog, M., Haustein, I., Müller, W., Briedigkeit, H., Göbel, U. B., & Lange, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120601.x · Cited by 213
Bio-inspired stable antimicrobial peptide coatings for dental applications
Holmberg, K. V., Abdolhosseini, M., Li, Y., Chen, X., Gorr, S.-U., & Aparicio, C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.017 · Cited by 210
Chen, W., Oh, S., Ong, A. P., Oh, N., Liu, Y., Courtney, H. S., Appleford, M., & Ong, J. L. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31197 · Cited by 206
Wafa, H., Grimer, R. J., Reddy, K., Jeys, L., Abudu, A., Carter, S. R., & Tillman, R. M. (2015) · The Bone & Joint Journal · doi:10.1302/0301-620x.97b2.34554 · Cited by 196
Chen, R., Willcox, M. D. P., Ho, K. K. K., Smyth, D., & Kumar, N. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.063 · Cited by 188
Hu, X., Neoh, K.-G., Shi, Z., Kang, E.-T., Poh, C., & Wang, W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.006 · Cited by 182
Surface-Grafted, Environmentally Sensitive Polymers for Biofilm Release
Ista, L. K., Pérez-Luna, V. H., & López, G. P. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.4.1603-1609.1999 · Cited by 174
Controlled release of vancomycin from thin sol–gel films on titanium alloy fracture plate material
Radin, S., & Ducheyne, P. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.035 · Cited by 172
Engineered Chimeric Peptides as Antimicrobial Surface Coating Agents toward Infection-Free Implants
Yazici, H., O’Neill, M. B., Kacar, T., Wilson, B. R., Oren, E. E., Sarikaya, M., & Tamerler, C. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b03697 · Cited by 172
Surface modification of biomaterials using plasma immersion ion implantation and deposition
Lü, T., Qiao, Y., & Liu, X. (2012) · Interface Focus · doi:10.1098/rsfs.2012.0003 · Cited by 162
Antibiotic resistance in human peri‐implantitis microbiota
Rams, T. E., Degener, J. E., & Winkelhoff, A. J. V. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12160 · Cited by 160
Hydrophobic polycationic coatings that inhibit biofilms and support bone healing during infection
Schaer, T. P., Stewart, S., Hsu, B. B., & Klibanov, A. M. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.038 · Cited by 160
Wang, R., Neoh, K. G., Shi, Z., Kang, E. T., Tambyah, P. A., & Chiong, E. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23342 · Cited by 160
Vancomycin Covalently Bonded to Titanium Beads Kills Staphylococcus aureus
Jose, B., Antoci, V., Zeiger, A. R., Wickstrom, E., & Hickok, N. J. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.06.013 · Cited by 159
Resistance to antimicrobial peptides in Gram-negative bacteria
Gruenheid, S., & Moual, H. L. (2012) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.2012.02528.x · Cited by 157
Yao, X., Zhang, X., Wu, H., Tian, L., Ma, Y., & Tang, B. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.12.083 · Cited by 156
Maddikeri, R. R., Tosatti, S. G. P., Schuler, M., Chessari, S., Textor, M., Richards, R. G., & Harris, L. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31323 · Cited by 154
Bacterial Adhesion on Titanium Nitride-coated and Uncoated Implants: An In Vivo Human Study
Scarano, A., Piattelli, M., Vrespa, G., Caputi, S., & Piattelli, A. (2003) · Journal of Oral Implantology · doi:10.1563/1548-1336(2003)029<0080:baotna>2.3.co;2 · Cited by 150
Gallardo-Moreno, A. M., Pacha‐Olivenza, M. A., Saldaña, L., Pérez-Giraldo, C., Bruque, J. M., Vilaboa, N. E., & González-Martín, M. L. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.028 · Cited by 148
de Ávila, É. D., Lima, B. P., Sekiya, T., Torii, Y., Ogawa, T., Shi, W., & Lux, R. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.030 · Cited by 144
He, S., Zhou, P., Wang, L., Xiong, X., Zhang, Y., Deng, Y., & Wei, S. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0169 · Cited by 142
Lv, H., Chen, Z., Yang, X., Cen, L., Zhang, X., & Gao, P. (2014) · Journal of Dentistry · doi:10.1016/j.jdent.2014.06.003 · Cited by 142
Cao, H., Qiao, Y., Liu, X., Lü, T., Cui, T., Meng, F., & Chu, P. K.-H. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.017 · Cited by 142
Godoy‐Gallardo, M., Mas‐Moruno, C., Yu, K., Manero, J. M., Gil, F. J., Kizhakkedathu, J. N., & Rius, D. R. (2014) · Biomacromolecules · doi:10.1021/bm501528x · Cited by 138
Malizos, K. N., Blauth, M., Danita, A., Capuano, N., Mezzoprete, R., Logoluso, N., Drago, L., & Romanò, C. L. (2017) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-017-0442-2 · Cited by 134
Sol-gel Chemistry in Medicinal Science
Coradin, T., Boissière, M., & Livage, J. (2006) · Current Medicinal Chemistry · doi:10.2174/092986706789803044 · Cited by 133
Bacterial adhesion mechanisms on dental implant surfaces and the influencing factors
Han, A., Tsoi, J. K. H., Rodrigues, F. P., Leprince, J. G., & Palin, W. M. (2016) · International Journal of Adhesion and Adhesives · doi:10.1016/j.ijadhadh.2016.03.022 · Cited by 132
Synthesis and Antimicrobial Activity of a Silver‐Hydroxyapatite Nanocomposite
Díaz, M., Barba, F., Miranda, M., Guitián, F., Torrecillas, R., & Moya, J. S. (2009) · Journal of Nanomaterials · doi:10.1155/2009/498505 · Cited by 131
Introduction to surface coating and modification for metallic biomaterials
Nouri, A., & Wen, C. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-303-4.00001-6 · Cited by 129
Staphylococcus aureus adhesion to different treated titanium surfaces
Harris, L. G., & Richards, R. G. (2004) · Journal of Materials Science Materials in Medicine · doi:10.1023/b:jmsm.0000021093.84680.bb · Cited by 128
Chen, X., Hirt, H., Li, Y., Gorr, S., & Aparicio, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111579 · Cited by 126
Modified implant surfaces show different biofilm compositions under in vivo conditions
Größner‐Schreiber, B., Teichmann, J., Hannig, M., Dörfer, C. E., Wenderoth, D. F., & Ott, S. J. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01729.x · Cited by 119
Groessner‐Schreiber, B., Hannig, M., Dück, A., Griepentrog, M., & Wenderoth, D. F. (2004) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2004.00171.x · Cited by 115
An Antibacterial Surface on Dental Implants, Based on the Photocatalytic Bactericidal Effect
Suketa, N., Sawase, T., Kitaura, H., Naito, M., Baba, K., Nakayama, K., Wennerberg, A., & Atsuta, M. (2005) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2005.tb00053.x · Cited by 113
Liu, W., Su, P., Chen, S., Wang, N., Ma, Y., Liu, Y., Wang, J., Zhang, Z., Li, H., & Webster, T. J. (2014) · Nanoscale · doi:10.1039/c4nr01531b · Cited by 113
Yoshinari, M., Kato, T., Matsuzaka, K., Hayakawa, T., & Shiba, K. (2009) · Biofouling · doi:10.1080/08927010903216572 · Cited by 112
Müller, R., Abke, J., Schnell, E., Scharnweber, D., Kujat, R., Englert, C., Taheri, D., Nerlich, M. N., & Angele, P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.019 · Cited by 109
Brohede, U., Forsgren, J., Roos, S., Mihranyan, A., Engqvist, H., & Strømme, M. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3749-6 · Cited by 101
de Waal, Y. C. M., Raghoebar, G. M., Meijer, H. J. A., Winkel, E. G., & Winkelhoff, A. J. V. (2014) · Clinical Oral Implants Research · doi:10.1111/clr.12419 · Cited by 100
Antimicrobial dental implant functionalization strategies —A systematic review
Grischke, J., Eberhard, J., & Stiesch, M. (2016) · Dental Materials Journal · doi:10.4012/dmj.2015-314 · Cited by 99
Gomes, F., Teixeira, P., & de Oliveira, R. P. S. (2013) · Biofouling · doi:10.1080/08927014.2013.848858 · Cited by 98
Jia, Z., Shi, Y., Xiong, P., Zhou, W., Cheng, Y., Zheng, Y., Xi, T., & Wei, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05198 · Cited by 95
Antibacterial burst-release from minimal Ag-containing plasma polymer coatings
Guimond-Lischer, S., Körner, E., Balazs, D. J., Shen, D., Wick, P., Grieder, K., Haas, D., Heuberger, M. P., & Hegemann, D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0596 · Cited by 90
Nano-Ag-loaded hydroxyapatite coatings on titanium surfaces by electrochemical deposition
Lu, X., Zhang, B., Wang, Y., Zhou, X., Weng, J., Qu, S., Feng, B., Watari, F., Ding, Y., & Leng, Y. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0366 · Cited by 90
Zhou, L., Lai, Y., Huang, W., Huang, S., Xu, Z., Chen, J., & Wu, D. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.03.008 · Cited by 89
Silver/hydroxyapatite composite coatings on porous titanium surfaces by sol‐gel method
Qu, J. H., Lu, X., Li, D., Ding, Y., Leng, Y., Weng, J., Qu, S., Feng, B., & Watari, F. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31784 · Cited by 86
Biofilm formation on titanium implants counteracted by grafting gallium and silver ions
Cochis, A., Azzimonti, B., Valle, C. D., Chiesa, R., Arciola, C. R., & Rimondini, L. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35270 · Cited by 84
Kucharíková, S., Gerits, E., Brucker, K. D., Braem, A., Čeh, K., Majdič, G., Španić, T., Pogorevc, E., Verstraeten, N., Tournu, H., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkv437 · Cited by 84
Bioactive polymer grafting onto titanium alloy surfaces
Michiardi, A., Hélary, G., Nguyen, P.-C. T., Gamble, L. J., Anagnostou, F., Castner, D. G., & Migonney, V. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.08.043 · Cited by 82
Self-citationShibata, Y., Suzuki, D., Omori, S., Tanaka, R., Murakami, A., Kataoka, Y., Baba, K., Kamijo, R., & Miyazaki, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.07.098 · Cited by 78
Yucesoy, D. T., Hnilova, M., Boone, K., Arnold, P. M., Snead, M. L., & Tamerler, C. (2015) · JOM · doi:10.1007/s11837-015-1350-7 · Cited by 78
Xu, J., Li, Y., Zhou, X., Li, Y., Gao, Z., Song, Y., & Schmuki, P. (2016) · Chemistry - A European Journal · doi:10.1002/chem.201505173 · Cited by 77
In situ analysis of multispecies biofilm formation on customized titanium surfaces
Fröjd, V., de Paz, L. C., Andersson, M., Wennerberg, A., Davies, J. R., & Svensäter, G. (2011) · Molecular Oral Microbiology · doi:10.1111/j.2041-1014.2011.00610.x · Cited by 76
Ti-GO-Ag nanocomposite: the effect of content level on the antimicrobial activity and cytotoxicity
Jin, J., Zhang, L., Shi, M., Zhang, Y., & Wang, Q. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s134843 · Cited by 76
Huang, Y., Zha, G., Luo, Q., Zhang, J., Zhang, F., Li, X., Zhao, S., Zhu, W., & Li, X. (2014) · Scientific Reports · doi:10.1038/srep06172 · Cited by 71
Chua, P. H., Neoh, K. G., Shi, Z., & Kang, E. T. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31854 · Cited by 69
Qian, W., Qiu, J., Su, J., & Liu, X. (2017) · Biomaterials Science · doi:10.1039/c7bm00931c · Cited by 68
Dubey, N., Ellepola, K., Decroix, F. E. D., Morin, J. L. P., Neto, A. C., Seneviratne, C. J., & Rosa, V. (2018) · Nanotoxicology · doi:10.1080/17435390.2018.1434911 · Cited by 68
Ren, N., Li, R., Chen, L., Wang, G., Liu, D., Wang, Y., Zheng, L., Tang, W., Yu, X., Jiang, H., et al. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm32434b · Cited by 66
Peyre, J., Humblot, V., Méthivier, C., Berjeaud, J., & Pradier, C. (2012) · The Journal of Physical Chemistry B · doi:10.1021/jp305597y · Cited by 64
Antimicrobial megaprostheses supported with iodine
Shirai, T., Tsuchiya, H., Nishida, H., Yamamoto, N., Watanabe, K., Nakase, J., Terauchi, R., Arai, Y., Fujiwara, H., & Kubo, T. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328214539365 · Cited by 63
Interaction of the antimicrobial peptide melimine with bacterial membranes
Rasul, R., Cole, N., Balasubramanian, D., Chen, R., Kumar, N., & Willcox, M. D. P. (2010) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2010.02.005 · Cited by 61
Faot, F., Cavalcanti, Y. W., Bertolini, M., Pinto, L. D. R., da Silva, W. J., & Cury, A. A. D. B. (2014) · BMC Oral Health · doi:10.1186/1472-6831-14-77 · Cited by 59
Lin, N., Huang, X., Zou, J., Zhang, X., Qin, L., Fan, A., & Tang, B. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.07.046 · Cited by 54
Proia, L. A., Hayden, M. K., Kammeyer, P. L., et al. (2004) · Clinical Infectious Diseases · doi:10.1086/422320 · Cited by 53
Bronk, J., Russell, B. H., Rivera, J. J., Pasqualini, R., Arap, W., Höök, M., & Barbu, E. M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.04.005 · Cited by 51
Self‐Assembled Antimicrobial and Biocompatible Copolymer Films on Titanium
Pfaffenroth, C., Winkel, A., Dempwolf, W., Gamble, L. J., Castner, D. G., Stiesch, M., & Menzel, H. (2011) · Macromolecular Bioscience · doi:10.1002/mabi.201100124 · Cited by 51
Unosson, E., Rius, D. R., Welch, K., & Engqvist, H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.09.048 · Cited by 49
Ta-doped multifunctional bioactive nanostructured films
Shtansky, D. V., Gloushankova, N. A., Bashkova, I. A., Kharitonova, M. A., Moizhess, T. G., Шевейко, А. Н., Kiryukhantsev–Korneev, P. V., Osaka, A., Mavrin, B. N., & Levashov, E. A. (2008) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2008.01.003 · Cited by 48
Mesoporous TiO2 implants for loading high dosage of antibacterial agent
Park, S. W., Lee, D., Choi, Y.-S., Jeon, H. B., Lee, C., Moon, J.-H., & Kwon, I. K. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.02.111 · Cited by 48
Liu, H., Wang, Wang, Boughton, & Sun (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s45742 · Cited by 46
Tetracycline tethered to titanium inhibits colonization by G ram‐negative bacteria
Davidson, H. M., Poon, M., Saunders, R., Shapiro, I. M., Hickok, N. J., & Adams, C. S. (2014) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33310 · Cited by 44
Cabal, B., Cafini, F., Esteban‐Tejeda, L., Alou, L., Bartolomé, J. F., Sevillano, D., López‐Píriz, R., Torrecillas, R., & Moya, J. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0042393 · Cited by 42
Córdoba, A., Hierro-Oliva, M., Pacha-Olivenza, M., Fernández-Calderón, M., Perelló, J., Isern, B., Gónzalez-Martín, M., Monjo, M., & Ramis, J. M. (2016) · ACS Applied Materials and Interfaces · doi:10.1021/acsami.6b02533 · Cited by 40
Si-doped multifunctional bioactive nanostructured films
Shtansky, D. V., Gloushankova, N. A., Шевейко, А. Н., Kiryukhantsev–Korneev, P. V., Bashkova, I. A., Mavrin, B. N., Ignatov, S. G., Filippovich, S. Y., & Rojas, T. C. (2010) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2010.07.063 · Cited by 39
Ji, M.-K., Park, S.-W., Lee, K.-M., et al. (2015) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2015.7.2.166 · Cited by 38
Cheng, H., Mao, L., Xu, X., Zeng, Y., Lan, D., Hu, H., Wu, X., You, H., Yang, X., Li, R., et al. (2014) · Biomaterials Science · doi:10.1039/c4bm00263f · Cited by 37
Alcheikh, A., Pavon‐Djavid, G., Hélary, G., Petite, H., Migonney, V., & Anagnostou, F. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-4932-3 · Cited by 35
Self-citationAntibacterial activity of a new broad‐spectrum antibiotic covalently bound to titanium surfaces
Gerits, E., Kucharíková, S., Dijck, P. V., Erdtmann, M., Krona, A., Lövenklev, M., Fröhlich, M., Dovgan, B., Impellizzeri, F., Braem, A., et al. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23238 · Cited by 35
Guimond-Lischer, S., Ren, Q., Braissant, O., Gruner, P. J., Wampfler, B., & Maniura‐Weber, K. (2016) · Biointerphases · doi:10.1116/1.4943225 · Cited by 34
Lee, J., Moon, S., Kim, K., & Kim, K.-N. (2012) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2011.654256 · Cited by 32
Felgueiras, H. P., Aissa, I. B., Evans, M. D. M., & Migonney, V. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-015-5596-y · Cited by 29
Self-citationAntibacterial activities of TiO 2 nanotubes on Porphyromonas gingivalis
Shi, X., Xu, Q., Tian, A., Tian, Y., Xue, X., Sun, H.-J., Yang, H., & Dong, C. (2015) · RSC Advances · doi:10.1039/c5ra00804b · Cited by 26
Ready, D. R., Theodoridis, G., Green, I., Ciric, L., Pratten, J. R., Tay, W. M., & McDonald, A. V. (2015) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2015.01.020 · Cited by 20
Calließ, T., Sluszniak, M., Winkel, A., Pfaffenroth, C., Dempwolf, W., Heuer, W., Menzel, H., Windhagen, H., & Stiesch, M. (2012) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2011-0041 · Cited by 19
Ioannidis, A., Thurnheer, T., Hofer, D., Sahrmann, P., Guggenheim, B., & Schmidlin, P. R. (2014) · Clinical Oral Implants Research · doi:10.1111/clr.12436 · Cited by 12
Fabrication and bioactivity evaluation of porous anodised TiO2 films in vitro
Teng, F., Li, J., Wu, Y., Chen, H., Zhang, Q., Hu, W., & Ou, G. (2014) · BioScience Trends · doi:10.5582/bst.2014.01035 · Cited by 8
Functionalization of Biomaterials and Applications
Falentin‐Daudre, C. (2014) · Biomaterials · doi:10.1002/9781119043553.ch6 · Cited by 6
Cited by
Mechano-bactericidal actions of nanostructured surfaces
Linklater, D. P., Baulin, V. A., Juodkazis, S., Crawford, R. J., Stoodley, P., & Ivanova, E. P. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-020-0414-z · Cited by 578
Masters, E. A., Trombetta, R. P., de Mesy Bentley, K. L., Boyce, B. F., Gill, A. L., Gill, S. R., Nishitani, K., Ishikawa, M., Morita, Y., Ito, H., et al. (2019) · Bone Research · doi:10.1038/s41413-019-0061-z · Cited by 575
Flieger, J., Flieger, W., Baj, J., & Maciejewski, R. (2021) · Materials · doi:10.3390/ma14154135 · Cited by 441
Surface Design for Antibacterial Materials: From Fundamentals to Advanced Strategies
Li, W., Thian, E. S., Wang, M., Wang, Z., & Ren, L. (2021) · Advanced Science · doi:10.1002/advs.202100368 · Cited by 429
The Impact of Dental Implant Surface Modifications on Osseointegration and Biofilm Formation
Kligman, S., Ren, Z., Chung, C.-H., Perillo, M. A., Chang, Y.-C., Koo, H., Zheng, Z., & Li, C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10081641 · Cited by 387
Metadata
- Authors
- Chouirfa, H., Bouloussa, H., Migonney, V., & Falentin-Daudré, C.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 83
- Pages
- 37-54
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2898513708
- Cited by
- 1,031
- References
- 121
- FWCI
- 81.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.