Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Antimicrobial peptide melimine coating for titanium and its in vivo antibacterial activity in rodent subcutaneous infection models

Open access
Chen, Renxun, Willcox, Mark D.P., Ho, Kitty Ka Kit, Smyth, Daniel, Kumar, Naresh·2016·Biomaterials

Abstract

Implant-associated infections represent a significant health problem and financial burden on healthcare systems. Current strategies for the treatment or prevention of such infections are still inadequate and new strategies are needed in this era of antibiotic resistance. Melimine, a synthetic antimicrobial peptide with broad spectrum activity against bacteria, fungi and protozoa, has been shown to be a promising candidate for development as antimicrobial coating for biomedical devices and implants. In this study, the in vitro and in vivo antimicrobial activity of melimine-coated titanium was tested. The titanium surface was amine-functionalised with 3-aminopropyltriethoxysilane (APTES) followed by reaction with a bifunctional linker 4-(N-maleimidomethyl)cyclohexane-1-carboxylic 3-sulfo-n-hydroxysuccinimide ester (Sulfo-SMCC) to yield a maleimide functionalised surface. Melimine was then tethered to the surface via a thioether linkage through a Michael addition reaction of the cysteine at its N-terminus with the maleimide moiety. Melimine coating significantly reduced in vitro adhesion and biofilm formation of Pseudomonas aeruginosa by up to 62% and Staphylococcus aureus by up to 84% on the titanium substrates compared to the blank (p < 0.05). The activity was maintained after ethylene oxide gas sterilisation. The coating was also challenged in both mouse and rat subcutaneous infection models and was able to reduce the bacterial load by up to 2 log10 compared to the uncoated surface (p < 0.05). Melimine coating is a promising candidate for development as a surface antimicrobial that can withstand industrial sterilisation while showing good biocompatibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2016.01.063

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Chen, R., Willcox, M. D. P., Ho, K. K. K., Smyth, D., & Kumar, N.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2016-04
Volume
85
Pages
142-151
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2288616517
Cited by
188
References
0
FWCI
10.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Antimicrobial peptide melimine coating for titanium and its in vivo antibacterial activity in rodent subcutaneous infection models. https://app.cochat.ai/papers/10.1016/j.biomaterials.2016.01.063
The paper
Chen, R., Willcox, M. D. P., Ho, K. K. K., Smyth, D., & Kumar, N. (2016). Antimicrobial peptide melimine coating for titanium and its in vivo antibacterial activity in rodent subcutaneous infection models. Biomaterials. https://doi.org/10.1016/j.biomaterials.2016.01.063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.