CoChat

Hybrid electrospun rapamycin-loaded small-diameter decellularized vascular grafts effectively inhibit intimal hyperplasia

Yang, Yang, Lei, Dong, Zou, Huanxue, Huang, Shixing, Yang, Qi, Li, Sen, Qing, Feng-Ling, Ye, Xiaofeng, You, Zhengwei, Zhao, Qiang · 2019 · Acta Biomaterialia
Cited by 85

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

For the surgical treatment of coronary artery disease, renal artery stenosis and other peripheral vascular diseases, there is significant demand for small diameter (inner diameter <6 mm) vascular grafts. However, autologous grafts are not always available when the substitute vascular grafts are severely diseased. In our previous work, hybrid small-diameter vascular grafts were successfully fabricated by combining electrospun polycaprolactone (PCL) and decellularized rat aorta (DRA). However, histological assessments of these grafts revealed the development of intimal hyperplasia, indicating potential negative impacts on the long-term patency of these grafts. To address this challenge, PCL nanofibers blended with rapamycin (RM) were electrospun outside the decellularized vascular graft to fabricate a RM-loaded hybrid tissue-engineered vascular graft (RM-HTEV), endowing the graft with a drug delivery function to prevent intimal hyperplasia. RM-HTEV possessed superior mechanical properties compared to DRA and exhibited a sustained drug release profile. To evaluate the applicability of RM-HTEV in vivo, abdominal aorta transplantation was performed on rats. Doppler sonography showed that the grafts were functional for up to 8 weeks in vivo. Moreover, histological analysis of explanted grafts 12 weeks postimplantation demonstrated that RM-HTEV significantly decreased neo-intimal hyperplasia compared with HTEV, without impairing reendothelialization and M2 macrophage polarization. Overall, RM-HTEV represents a promising strategy for developing small-diameter vascular grafts with great clinical translational potential. STATEMENT OF SIGNIFICANCE: In this study, a new type of rapamycin-loaded hybrid tissue-engineered vascular graft (RM-HTEV) was fabricated using electrospinning technology. The unique hybrid bi-layer structure endowed the RM-HTEV with multi-functionality: the exterior rapamycin-loaded electrospun PCL nanofibrous layer enhanced the mechanical properties of the graft and possessed drug releasing property; the interior decellularized aorta layer with porous structure could facilitate cell proliferation and migration. In in vivo implantation experiment, RM-HTEV exhibited satisfying long-term patency rate and significantly inhibited intimal hyperplasia without impairing re-endothelialization and M2 macrophage polarization. This strategy is expected to be a promising strategy for developing bioactive small-diameter vascular grafts with great clinical translational potential.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.actbio.2019.06.037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 85

Metadata

Authors
Yang, Y., Lei, D., Zou, H., Huang, S., Yang, Q., Li, S., Qing, F.-L., Ye, X., You, Z., & Zhao, Q.
Venue
Acta Biomaterialia
Publisher
Elsevier BV
Published
2019-10
Volume
97
Pages
321-332
ISSN
1742-7061 (ISSN-L)
OpenAlex
W2937507052
Cited by
85
References
2
FWCI
9.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.