The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Electrically conductive 3D printed Ti3C2T MXene-PEG composite constructs for cardiac tissue engineering
Open accessAbstract
Tissue engineered cardiac patches have great potential as a therapeutic treatment for myocardial infarction (MI). However, for successful integration with the native tissue and proper function of the cells comprising the patch, it is crucial for these patches to mimic the ordered structure of the native extracellular matrix and the electroconductivity of the human heart. In this study, a new composite construct that can provide both conductive and topographical cues for human induced pluripotent stem cell derived cardiomyocytes (iCMs) is developed for cardiac tissue engineering applications. The constructs are fabricated by 3D printing conductive titanium carbide (Ti3C2Tx) MXene in pre-designed patterns on polyethylene glycol (PEG) hydrogels, using aerosol jet printing, at a cell-level resolution and then seeded with iCMs and cultured for one week with no signs of cytotoxicity. The results presented in this work illustrate the vital role of 3D-printed Ti3C2Tx MXene on aligning iCMs with a significant increase in MYH7, SERCA2, and TNNT2 expressions, and with an improved synchronous beating as well as conduction velocity. This study demonstrates that 3D printed Ti3C2Tx MXene can potentially be used to create physiologically relevant cardiac patches for the treatment of MI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lian, X., Zhang, J., Azarin, S. M., Zhu, K., Hazeltine, L. B., Bao, X., Hsiao, C., Kamp, T. J., & Palecek, S. P. (2013) · Nature Protocols · doi:10.1038/nprot.2012.150 · Cited by 1,748
Carbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946
Self-citationThoniyot, P., Tan, M. J., Karim, A. A., Young, D. J., & Loh, X. J. (2015) · Advanced Science · doi:10.1002/advs.201400010 · Cited by 928
Structural and Functional Maturation of Cardiomyocytes Derived from Human Pluripotent Stem Cells
Lundy, S. D., Zhu, W.-Z., Regnier, M., & Laflamme, M. A. (2013) · Stem Cells and Development · doi:10.1089/scd.2012.0490 · Cited by 738
Cardiomyocyte Maturation: New Phase in Development
Guo, Y., & Pu, W. T. (2020) · Circulation Research · doi:10.1161/circresaha.119.315862 · Cited by 653
Bejleri, D., Streeter, B. W., Nachlas, A. L. Y., Brown, M. E., Gaetani, R., Christman, K. L., & Davis, M. E. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800672 · Cited by 255
Controlling the contractile strength of engineered cardiac muscle by hierarchal tissue architecture
Feinberg, A. W., Alford, P. W., Jin, H., Ripplinger, C. M., Werdich, A. A., Sheehy, S. P., Grosberg, A., & Parker, K. K. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.043 · Cited by 240
Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium
Turnbull, I. C., Karakikes, I., Serrao, G. W., Backeris, P., Lee, J., Xie, C., Senyei, G., Gordon, R. E., Li, R. A., Akar, F. G., et al. (2014) · The FASEB Journal · doi:10.1096/fj.13-228007 · Cited by 184
Self-Organization of Muscle Cell Structure and Function
Grosberg, A., Kuo, P.-L., Guo, C.-L., Geisse, N. A., Bray, M.-A., Adams, W. J., Sheehy, S. P., & Parker, K. K. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1001088 · Cited by 116
Engineered cardiac organoid chambers: toward a functional biological model ventricle
Lee, E. J., Kim, D. E., Azeloglu, E. U., & Costa, K. D. (2008) · Tissue Engineering Part A · doi:10.1089/tea.2007.0351 · Cited by 84
Cited by
A review of etching methods of MXene and applications of MXene conductive hydrogels
Zhou, C., Zhao, X., Xiong, Y., Tang, Y., Ma, X., Tao, Q., Sun, C., & Xu, W. (2022) · European Polymer Journal · doi:10.1016/j.eurpolymj.2022.111063 · Cited by 287
Maleki, A., Ghomi, M., Nikfarjam, N., Akbari, M., Sharifi, E., Shahbazi, M., Kermanian, M., Seyedhamzeh, M., Nazarzadeh Zare, E., Mehrali, M., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202203430 · Cited by 262
Emerging technologies for cardiac tissue engineering and artificial hearts
Sun, L., Wang, Y., Xu, D., & Zhao, Y. (2023) · Smart Medicine · doi:10.1002/smmd.20220040 · Cited by 44
Engineering the cardiac tissue microenvironment
Ronan, G., Bahcecioglu, G., Aliyev, N., & Zorlutuna, P. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0ea7 · Cited by 4
Self-citation
Metadata
- Authors
- Basara, G., Saeidi-Javash, M., Ren, X., Bahcecioglu, G., Wyatt, B. C., Anasori, B., Zhang, Y., & Zorlutuna, P.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2022-02
- Volume
- 139
- Pages
- 179-189
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W3113546541
- Cited by
- 162
- References
- 11
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrically conductive 3D printed Ti3C2T MXene-PEG composite constructs for cardiac tissue engineering. https://app.cochat.ai/papers/10.1016/j.actbio.2020.12.033
- The paper
- Basara, G., Saeidi-Javash, M., Ren, X., Bahcecioglu, G., Wyatt, B. C., Anasori, B., Zhang, Y., & Zorlutuna, P. (2022). Electrically conductive 3D printed Ti3C2T MXene-PEG composite constructs for cardiac tissue engineering. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2020.12.033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.