Bioreactor technologies to support liver function in vitro
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Liver is a central nexus integrating metabolic and immunologic homeostasis in the human body, and the direct or indirect target of most molecular therapeutics. A wide spectrum of therapeutic and technological needs drive efforts to capture liver physiology and pathophysiology in vitro, ranging from prediction of metabolism and toxicity of small molecule drugs, to understanding off-target effects of proteins, nucleic acid therapies, and targeted therapeutics, to serving as disease models for drug development. Here we provide perspective on the evolving landscape of bioreactor-based models to meet old and new challenges in drug discovery and development, emphasizing design challenges in maintaining long-term liver-specific function and how emerging technologies in biomaterials and microdevices are providing new experimental models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Hepatic Stellate Cells: Protean, Multifunctional, and Enigmatic Cells of the Liver
Friedman, S. L. (2008) · Physiological Reviews · doi:10.1152/physrev.00013.2007 · Cited by 2,842 · cited 1×
“Quiescent hepatic stellate cells comprise 5–8% of total liver cells, are present within the space of Disse at a ratio of approximately 1 stellate cell for 6 hepatocytes, store 80% of body vitamin A, and participate in hepatic wound healing, regulation of sinusoidal blood flow, angiogenesis and hepatocyte growth [13].”
The gut flora as a forgotten organ
O'Hara, A. M., & Shanahan, F. (2006) · The EMBO Reports · doi:10.1038/sj.embor.7400731 · Cited by 2,791
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Endotoxin tolerance: new mechanisms, molecules and clinical significance
Biswas, S. K., & Lopez-Collazo, E. (2009) · Trends in Immunology · doi:10.1016/j.it.2009.07.009 · Cited by 1,318
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280 · cited 2×
“Excellent perspective on how these types of microfluidic systems for slice culture and other forms of culture, including limitations of the PDMS materials and possible mitigations of these limitations [64], is provided in recent reviews by Groothuis and co-workers [1,3,143].”
Crispe, I. N. (2009) · Annual Review of Immunology · doi:10.1146/annurev.immunol.021908.132629 · Cited by 986
Toll‐like receptors and adaptor molecules in liver disease: Update†
Seki, E., & Brenner, D. A. (2008) · Hepatology · doi:10.1002/hep.22306 · Cited by 722
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Cited by
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
A decade of progress in tissue engineering
Khademhosseini, A., & Langer, R. (2016) · Nature Protocols · doi:10.1038/nprot.2016.123 · Cited by 747
Three-dimensional cell culture systems as an in vitro platform for cancer and stem cell modeling
Chaicharoenaudomrung, N., Kunhorm, P., & Noisa, P. (2019) · World Journal of Stem Cells · doi:10.4252/wjsc.v11.i12.1065 · Cited by 360
Factors involved in cancer metastasis: a better understanding to “seed and soil” hypothesis
Liu, Q., Zhang, H., Jiang, X., Qian, C., Liu, Z., & Luo, D. (2017) · Molecular Cancer · doi:10.1186/s12943-017-0742-4 · Cited by 332
In silico clinical trials: how computer simulation will transform the biomedical industry
Viceconti, M., Henney, A., & Morley-Fletcher, E. (2016) · International Journal of Clinical Trials · doi:10.18203/2349-3259.ijct20161408 · Cited by 289
Metadata
- Authors
- Ebrahimkhani, M. R., Neiman, J. A. S., Raredon, M. S. B., Hughes, D. J., & Griffith, L. G.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 69-70
- Pages
- 132-157
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2273947099
- Cited by
- 135
- References
- 32
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioreactor technologies to support liver function in vitro. https://app.cochat.ai/papers/10.1016/j.addr.2014.02.011
- The paper
- Ebrahimkhani, M. R., Neiman, J. A. S., Raredon, M. S. B., Hughes, D. J., & Griffith, L. G. (2014). Bioreactor technologies to support liver function in vitro. Advanced Drug Delivery Reviews. https://doi.org/10.1016/j.addr.2014.02.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.