The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Heparin coatings for improving blood compatibility of medical devices
Open accessAbstract
Blood contact with biomaterials triggers activation of multiple reactive mechanisms that can impair the performance of implantable medical devices and potentially cause serious adverse clinical events. This includes thrombosis and thromboembolic complications due to activation of platelets and the coagulation cascade, activation of the complement system, and inflammation. Numerous surface coatings have been developed to improve blood compatibility of biomaterials. For more than thirty years, the anticoagulant drug heparin has been employed as a covalently immobilized surface coating on a variety of medical devices. This review describes the fundamental principles of non-eluting heparin coatings, mechanisms of action, and clinical applications with focus on those technologies which have been commercialized. Because of its extensive publication history, there is emphasis on the CARMEDA ® BioActive Surface (CBAS ® Heparin Surface), a widely used commercialized technology for the covalent bonding of heparin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Temporal Aspects of Heparin-Induced Thrombocytopenia
Warkentin, T. E., & Kelton, J. G. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104263441704 · Cited by 977
Encyclopedia of Biomaterials and Biomedical Engineering
(2008) · CRC Press eBooks · doi:10.1201/9780429154065 · Cited by 700
Bertrand, M. E., Legrand, V., Boland, J., Fleck, E., Bonnier, J., Emmanuelson, H., Vrolix, M., Missault, L., Chierchia, S., Casaccia, M., et al. (1998) · Circulation · doi:10.1161/01.cir.98.16.1597 · Cited by 583
Medical device‐induced thrombosis: what causes it and how can we prevent it?
Jaffer, I. H., Fredenburgh, J. C., Hirsh, J., & Weitz, J. I. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12961 · Cited by 557
The separation of active and inactive forms of heparin
Lam, L. H., Silbert, J. E., & Rosenberg, R. D. (1976) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(76)90558-1 · Cited by 492
Delayed-Onset Heparin-Induced Thrombocytopenia and Thrombosis
Warkentin, T. E., & Kelton, J. G. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-7-200110020-00009 · Cited by 467
Heparin Bonding on Colloidal Graphite Surfaces
Gott, V. L., Whiffen, J. D., & Dutton, R. C. (1963) · Science · doi:10.1126/science.142.3597.1297 · Cited by 457
Cited by
Osman, A. I., Chen, Z., Elgarahy, A. M., Farghali, M., Mohamed, I. M. A., Priya, A. K., Hawash, H. B., & Yap, P. (2024) · Advanced Energy and Sustainability Research · doi:10.1002/aesr.202400011 · Cited by 365
Metadata
- Authors
- Biran, R., & Pond, D.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 112
- Pages
- 12-23
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2563390568
- Cited by
- 334
- References
- 75
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heparin coatings for improving blood compatibility of medical devices. https://app.cochat.ai/papers/10.1016/j.addr.2016.12.002
- The paper
- Biran, R., & Pond, D. (2017). Heparin coatings for improving blood compatibility of medical devices. Advanced Drug Delivery Reviews. https://doi.org/10.1016/j.addr.2016.12.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.