Cited by 16Biomedical and Chemical ResearchClinical Laboratory Practices and Quality ControlRespiratory Support and Mechanisms

Accuracy of portable quantitative capnometers and capnographs under prehospital conditions

Biedler, Andreas E, Wilhelm, Wolfram, Kreuer, Sascha, Soltesz, Stefan, Bach, Friedhelm, Mertzlufft, Friedrich O, Molter, Gerd P·2003·The American Journal of Emergency Medicine

Abstract

This study was designed to assess the pCO(2) accuracy of portable mainstream (Tidal Wave, Novametrix; Propaq 106, Protocol) and sidestream capnometers (Capnocheck 8200, BCI; Capnocount mini, Weinmann; NPB-75, Nellcor Puritan Bennett; SC-210, Pryon) with respect to international standards and preclinical emergency conditions. Measurements were performed under temperature conditions of +22 degrees C and -20 degrees C using dry gas mixtures with different CO(2) concentrations (STPD) and in patients ventilated with pure oxygen (BTPS). Accuracy presented to be between +1% (Capnocheck) and +12% (Propaq) (STPD) and between -0.4% (Capnocheck) and +11% (Tidal Wave) (BTPS). The measurements were affected by low ambient temperature only in the NPB-75 (+15%). Our results indicate that portable quantitative capnometers are able to fulfill accuracy requirements as requested by international standards but can be affected by changing ambient temperatures.

Integrity signals

Registry

Crossref · 10.1016/j.ajem.2003.08.005

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Biedler, A. E., Wilhelm, W., Kreuer, S., Soltesz, S., Bach, F., Mertzlufft, F. O., & Molter, G. P.
Affiliations
  • Universitätsklinikum des Saarlandes (DE)
  • Klinikum Bielefeld (DE)
  • Klinikum Leverkusen (DE)
Corresponding author
Biedler, Andreas E
Venue
The American Journal of Emergency Medicine
Publisher
Elsevier BV
Published
2003-11
Volume
21
Issue
7
Pages
520-524
ISSN
0735-6757 (ISSN-L)
OpenAlex
W2168190041
Cited by
16
References
14
Citations by year
2024: 1 · 2023: 1 · 2017: 1 · 2015: 1 · 2013: 3 · 2012: 1
FWCI
0.32
Type
journal article
Language
en
Open access
closed
Locations
  • The American Journal of Emergency Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Biomedical and Chemical Research
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
capnometer, capnography, end-tidal carbon dioxide, measurement accuracy, prehospital care, portable monitoring device, ambient temperature effects, oxygen ventilation
MeSH terms
Emergency Treatment, Equipment Design, Humans, Statistics, Nonparametric, Capnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review