Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 361

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

High discordance of chest x-ray and computed tomography for detection of pulmonary opacities in ED patients: implications for diagnosing pneumonia

Open access
Self, Wesley H., Courtney, D. Mark, McNaughton, Candace D., Wunderink, Richard G., Kline, Jeffrey A.·2013·The American Journal of Emergency Medicine

Abstract

Objective To evaluate the diagnostic performance of chest x-ray (CXR) compared to computed tomography (CT) for detection of pulmonary opacities in adult emergency department (ED) patients. Methods We conducted an observational cross sectional study of adult patients presenting to 12 EDs in the United States from July 1, 2003 through November 30, 2006 who underwent both CXR and chest CT for routine clinical care. CXRs and CT scans performed on the same patient were matched. CXRs and CT scans were interpreted by attending radiologists and classified as containing pulmonary opacities if the final radiologist report noted opacity, infiltrate, consolidation, pneumonia, or bronchopneumonia. Using CT as a criterion standard, the diagnostic test characteristics of CXR to detect pulmonary opacities were calculated. Results The study cohort included 3,423 patients. Shortness of breath, chest pain and cough were the most common complaints, with 96.1% of subjects reporting at least one of these symptoms. Pulmonary opacities were visualized on 309 (9.0%) CXRs and 191 (5.6 %) CT scans. CXR test characteristics for detection of pulmonary opacities included: sensitivity 43.5% (95% CI: 36.4%–50.8%); specificity 93.0% (95% CI: 92.1%–93.9%); positive predictive value 26.9% (95% CI: 22.1%–32.2%); and negative predictive value 96.5% (95% CI: 95.8%–97.1%). Conclusion In this multicenter cohort of adult ED patients with acute cardiopulmonary symptoms, CXR demonstrated poor sensitivity and positive predictive value for detecting pulmonary opacities. Reliance on CXR to identify pneumonia may lead to significant rates of misdiagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajem.2012.08.041

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 361

Metadata

Authors
Self, W. H., Courtney, D. M., McNaughton, C. D., Wunderink, R. G., & Kline, J. A.
Venue
The American Journal of Emergency Medicine
Publisher
Elsevier BV
Published
2013-02
Volume
31
Issue
2
Pages
401-405
ISSN
0735-6757 (ISSN-L)
OpenAlex
W2009245149
Cited by
361
References
19
FWCI
5.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High discordance of chest x-ray and computed tomography for detection of pulmonary opacities in ED patients: implications for diagnosing pneumonia. https://app.cochat.ai/papers/10.1016/j.ajem.2012.08.041
The paper
Self, W. H., Courtney, D. M., McNaughton, C. D., Wunderink, R. G., & Kline, J. A. (2013). High discordance of chest x-ray and computed tomography for detection of pulmonary opacities in ED patients: implications for diagnosing pneumonia. The American Journal of Emergency Medicine. https://doi.org/10.1016/j.ajem.2012.08.041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.