The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Abstract
The introduction of helical single-detector row computed tomography (CT) and, more recently, multi-detector row CT has greatly increased the clinical indications for CT. Correspondingly, CT examinations now account for greater than one-half of the radiation dose due to medical procedures in the population of North America. The level of CT radiation dose, especially in the pediatric population, is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT. A table of reference dose values is provided. Given the wide variation documented in chest CT radiation exposure, the authors suggest that reference standards be promoted to minimize excessive CT radiation exposure. In addition, further research into the complex relationship between radiation exposure, image quality, and diagnostic accuracy should be encouraged in order to establish the minimum radiation dose necessary to provide adequate diagnostic information for standard clinical questions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cited by
MacMahon, H., Austin, J. H. M., Gamsu, G., Herold, C. J., Jett, J. R., Naidich, D. P., Patz, E. F., & Swensen, S. J. (2005) · Radiology · doi:10.1148/radiol.2372041887 · Cited by 1,574
Evaluation of Individuals With Pulmonary Nodules: When Is It Lung Cancer?
Gould, M. K., Donington, J., Lynch, W. R., Mazzone, P. J., Midthun, D. E., Naidich, D. P., & Wiener, R. S. (2013) · Chest · doi:10.1378/chest.12-2351 · Cited by 1,450
Interstitial lung disease guideline
Wells, A. U., Hirani, N., & on behalf of the BTS Interstitial Lung Disease Guideline Group, A. S. O. T. B. T. S. S. O. C. C. (2008) · Thorax · doi:10.1136/thx.2008.101691 · Cited by 866
Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?
Gould, M. K., Fletcher, J., Iannettoni, M. D., Lynch, W. R., Midthun, D. E., Naidich, D. P., & Ost, D. E. (2007) · Chest · doi:10.1378/chest.07-1353 · Cited by 503
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Metadata
- Authors
- Mayo, J. R., Aldrich, J., & Müller, N. L.
- Venue
- Radiology
- Published
- 2003-07
- Volume
- 228
- Issue
- 1
- Pages
- 15-21
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2081187499
- Cited by
- 359
- References
- 1
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation Exposure at Chest CT: A Statement of the Fleischner Society. https://app.cochat.ai/papers/10.1148/radiol.2281020874
- The paper
- Mayo, J. R., Aldrich, J., & Müller, N. L. (2003). Radiation Exposure at Chest CT: A Statement of the Fleischner Society. Radiology. https://doi.org/10.1148/radiol.2281020874
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.