CoChat

Standard long IV catheters versus extended dwell catheters: A randomized comparison of ultrasound-guided catheter survival

Open access
Bahl, Amit, Hang, Bophal, Brackney, Abigail, Joseph, Steven, Karabon, Patrick, Mohammad, Ammanee, Nnanabu, Ijeoma, Shotkin, Paul · 2019 · The American Journal of Emergency Medicine
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Establishing peripheral intravenous (IV) access is a vital step in providing emergency care. Ten to 30% of Emergency Department (ED) patients have difficult vascular access (DVA). Even after cannulation, early failure of US-guided IV catheters is a common complication. The primary goal of this study was to compare survival of a standard long IV catheter to a longer extended dwell catheter. METHODS: This study was a prospective, randomized comparative evaluation of catheter longevity. Two catheters were used in the comparison: [1] a standard long IV catheter, the 4.78 cm 20 gauge Becton Dickinson (BD); and [2] a 6 cm 3 French (19.5 gauge) Access Scientific POWERWAND™ extended dwell catheter (EDC). Adult DVA patients in the ED with vein depths of 1.20 cm-1.60 cm and expected hospital admissions of at least 24 h were recruited. RESULTS: 120 patients were enrolled. Ultimately, 70 patients were included in the survival analysis, with 33 patients in the EDC group and 37 patients in the standard long IV group. EDC catheters had lower rates of failure (p = 0.0016). Time to median catheter survival was 4.04 days for EDC catheters versus 1.25 days for the standard long IV catheter. Multivariate survival analysis also showed a significant survival benefit for the EDC catheter (p = 0.0360). CONCLUSION: A longer extended dwell catheter represents a viable and favorable alternative to the standard longer IVs used for US-guided cannulation of veins >1.20 cm in depth. These catheters have significantly improved survival rates with similar insertion success characteristics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajem.2018.07.031

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 70

Metadata

Authors
Bahl, A., Hang, B., Brackney, A., Joseph, S., Karabon, P., Mohammad, A., Nnanabu, I., & Shotkin, P.
Venue
The American Journal of Emergency Medicine
Publisher
Elsevier BV
Published
2019-04
Volume
37
Issue
4
Pages
715-721
ISSN
0735-6757 (ISSN-L)
OpenAlex
W2884925441
Cited by
70
References
3
FWCI
9.01
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standard long IV catheters versus extended dwell catheters: A randomized comparison of ultrasound-guided catheter survival. https://app.cochat.ai/papers/10.1016/j.ajem.2018.07.031
The paper
Bahl, A., Hang, B., Brackney, A., Joseph, S., Karabon, P., Mohammad, A., Nnanabu, I., & Shotkin, P. (2019). Standard long IV catheters versus extended dwell catheters: A randomized comparison of ultrasound-guided catheter survival. The American Journal of Emergency Medicine. https://doi.org/10.1016/j.ajem.2018.07.031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.