Opportunities and challenges in utilizing electronic health records for infection surveillance, prevention, and control
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
There are unique patient safety challenges in the prevention and control of health care-associated infections (HAI). It is estimated that approximately 2 million HAI occur every year in the United States, and each infection increases the risk of death by as much as 6 times. This amounts to an estimated 90,000 deaths annually and $4.5 billion excess health care costs. The emergence of specific multidrug-resistant organisms (MDRO), the growing number of immunocompromised patients, and the increasing number of invasive procedures and medical device implantations are posing new challenges for infection control. How many of these HAI are preventable remains unclear, but payers such as the Centers for Medicare Medicare & Medicaid Services have already enacted rules that preclude reimbursement for certain conditions that are attributed to hospitalization, eg, catheter-associated urinary tract infections. Initiatives such as the Institute for Healthcare Improvement’s 100,000 and 5 Millions Lives Campaigns, The Joint Commission’s National Patient Safety Goals, and guidelines for public reporting of HAI reflect growing concern over HAI and the need for their prevention. Many such initiatives are evidence based and have shown to reduce the rate of HAI. For example, adherence to the ‘‘bundle’’ (hand hygiene, full-barrier precautions during insertion of catheter, using chlorhexidine antiseptic to clean the skin, avoiding the femoral site, and removing unnecessary catheters)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387 · cited 2×
“0 DTD ymic1268 11 M was recently shown to reduce significantly the rates of catheter-related bloodstream infections among patients receiving care in intensive care units.(5) However, creating a successful culture of safety requires a significant investment in both education of health care personnel and infrastructure…”
BackgroundGarg, A. X., Adhikari, N. K. J., McDonald, H., Rosas-Arellano, M. P., Devereaux, P. J., Beyene, J., Sam, J., & Haynes, R. B. (2005) · JAMA · doi:10.1001/jama.293.10.1223 · Cited by 2,936
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260 · cited 2×
“CPOE can support process improvement, increase accuracy and legibility of the order, and integrate CDS into the order-entry process.(9,10) CDS can provide alerts for drug-drug, drug-allergy, and drug-food interactions based on routinely updated drug formularies.”
BackgroundTypes of Unintended Consequences Related to Computerized Provider Order Entry
Campbell, E. M., Sittig, D. F., Ash, J. S., Guappone, K. P., & Dykstra, R. H. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2042 · Cited by 823
Computer Physician Order Entry: Benefits, Costs, and Issues
Kuperman, G. J., & Gibson, R. F. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-1-200307010-00010 · Cited by 438 · cited 1×
“CPOE can support process improvement, increase accuracy and legibility of the order, and integrate CDS into the order-entry process.(9,10) CDS can provide alerts for drug-drug, drug-allergy, and drug-food interactions based on routinely updated drug formularies.”
BackgroundImproving Preventive Care by Prompting Physicians
Balas, E. A. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.3.301 · Cited by 385 · cited 2×
“CDS can also be customized to generate reminders to enhance vaccination rates and preventive screening that have shown to be more effective and less expensive than the paper-based reminders.(11,12) It is estimated that such computerized reminders to providers at the point of care can lead to a 6.”
Background
Cited by
Reeves, J. J., Hollandsworth, H. M., Torriani, F. J., Taplitz, R., Abeles, S., Tai-Seale, M., Millen, M., Clay, B. J., & Longhurst, C. A. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa037 · Cited by 429
“17 Unfortunately, despite the recent Ebola epidemic, the infrastructure for outbreak management was not present in many US health systems and their EHR applications.”
Secondary Use of Electronic Health Record: Opportunities and Challenges
Shah, S. M., & Khan, R. A. (2020) · IEEE Access · doi:10.1109/access.2020.3011099 · Cited by 158
Spiranovic, C., Matthews, A., Scanlan, J., & Kirkby, K. C. (2016) · Advances in Mental Health · doi:10.1080/18387357.2015.1063635 · Cited by 37
“Atreja et al. (2008) also acknowledge various impediments to widespread implementation of EHRs for these purposes, including costs, lack of interoperability standards and the risk of unintended and adverse consequences in cases of poor implementation.”
BackgroundMethodApplication of telemedicine in COVID-19: a bibliometric analysis
Lan, X., Yu, H., & Cui, L. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.908756 · Cited by 28
Metadata
- Authors
- Atreja, A., Gordon, S. M., Pollock, D. A., Olmsted, R. N., & Brennan, P. J.
- Venue
- American Journal of Infection Control
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 36
- Issue
- 3
- Pages
- S37-S46
- ISSN
- 0196-6553 (ISSN-L)
- OpenAlex
- W2035450555
- Cited by
- 57
- References
- 6
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.