The DOI matches its Crossref record.
Imaging the Infant Retina with a Hand-held Spectral-Domain Optical Coherence Tomography Device
Abstract
PURPOSE To evaluate and treat infant retina through the use of a hand-held spectral-domain optical coherence tomography (SD OCT) device in selected cases of Shaken Baby syndrome (SBS). DESIGN Observational case series. METHODS A novel SD OCT system was optimized and evaluated for infant imaging. An adult eye was imaged with both a standard clinical SD OCT system and the hand-held system. Four eyes of two infants with a history of SBS were imaged with the hand-held system. One infant was imaged again during follow-up examinations. Robust image processing algorithms were developed to create high-quality images. Images were assessed for usefulness in demonstrating pertinent morphologic features. RESULTS The novel SD OCT unit proved effective for data acquisition and comparable with conventional chin-rest SD OCT. Rapid data acquisition limited motion artifact within the B-scan, although there was slight motion between B scans. The SD OCT images provided previously unseen details with regard to the morphologic features of retinal lesions in these infant eyes. This information influenced prognosis and management. CONCLUSIONS As with adults, the hand-held customized SD OCT proved to be an invaluable tool in the differentiation of disease processes or injury in these eyes under study. SD OCT imaging systems may be considered a useful adjunct to RetCam fundus photography for assessment and clinical management in cases of SBS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sparsity based denoising of spectral domain optical coherence tomography images
Fang, L., Li, S., Nie, Q., Izatt, J. A., Toth, C. A., & Farsiu, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000927 · Cited by 268
Self-citationIntraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Metadata
- Authors
- Scott, A. W., Farsiu, S., Enyedi, L. B., Wallace, D. K., & Toth, C. A.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 147
- Issue
- 2
- Pages
- 364-373.e2
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2050341950
- Cited by
- 177
- References
- 0
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging the Infant Retina with a Hand-held Spectral-Domain Optical Coherence Tomography Device. https://app.cochat.ai/papers/10.1016/j.ajo.2008.08.010
- The paper
- Scott, A. W., Farsiu, S., Enyedi, L. B., Wallace, D. K., & Toth, C. A. (2009). Imaging the Infant Retina with a Hand-held Spectral-Domain Optical Coherence Tomography Device. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2008.08.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.