Imaging the Infant Retina with a Hand-held Spectral-Domain Optical Coherence Tomography Device
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE To evaluate and treat infant retina through the use of a hand-held spectral-domain optical coherence tomography (SD OCT) device in selected cases of Shaken Baby syndrome (SBS). DESIGN Observational case series. METHODS A novel SD OCT system was optimized and evaluated for infant imaging. An adult eye was imaged with both a standard clinical SD OCT system and the hand-held system. Four eyes of two infants with a history of SBS were imaged with the hand-held system. One infant was imaged again during follow-up examinations. Robust image processing algorithms were developed to create high-quality images. Images were assessed for usefulness in demonstrating pertinent morphologic features. RESULTS The novel SD OCT unit proved effective for data acquisition and comparable with conventional chin-rest SD OCT. Rapid data acquisition limited motion artifact within the B-scan, although there was slight motion between B scans. The SD OCT images provided previously unseen details with regard to the morphologic features of retinal lesions in these infant eyes. This information influenced prognosis and management. CONCLUSIONS As with adults, the hand-held customized SD OCT proved to be an invaluable tool in the differentiation of disease processes or injury in these eyes under study. SD OCT imaging systems may be considered a useful adjunct to RetCam fundus photography for assessment and clinical management in cases of SBS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pyramid approach to subpixel registration based on intensity
Thevenaz, P., Ruttimann, U. E., & Unser, M. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.650848 · Cited by 3,078
Fast and Robust Multiframe Super Resolution
Farsiu, S., Robinson, M. D., Elad, M., & Milanfar, P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.834669 · Cited by 2,090
Self-citationKernel Regression for Image Processing and Reconstruction
Takeda, H., Farsiu, S., & Milanfar, P. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.888330 · Cited by 1,340
Self-citationOptical Coherence Tomography Use in Evaluation of the Vitreoretinal Interface: A Review
Mirza, R. G., Johnson, M. W., & Jampol, L. M. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.04.007 · Cited by 158
Perimacular retinal folds from childhood head trauma
Lantz, P., Sinal, S. H., Stanton, C. A., & Weaver, R. G. (2004) · BMJ · doi:10.1136/bmj.328.7442.754 · Cited by 136
Ultrahigh-Resolution Optical Coherence Tomography of Surgically Closed Macular Holes
Ko, T. H., Witkin, A. J., Fujimoto, J. G., Chan, A. Y., Rogers, A. H., Baumal, C. R., Schuman, J. S., Drexler, W., Reichel, E., & Duker, J. S. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.6.827 · Cited by 119
Retinal proliferation in response to vitreous hemoglobin or iron.
Burke, J. M., & Smith, J. M. (1981) · PubMed · Cited by 69
Stopa, M., Bower, B. A., Davies, E., Izatt, J. A., & Toth, C. A. (2008) · Retina · doi:10.1097/iae.0b013e3181567798 · Cited by 58
Self-citationConstrained, globally optimal, multi-frame motion estimation
Farsiu, S., Elad, M., & Milanfar, P. (2005) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssp.2005.1628814 · Cited by 38
Self-citationPathogenesis of the Vitreous Cloud Emanating From Subretinal Hemorrhage
LINCOFF, H. A. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.1.91 · Cited by 23
Cited by
Sparsity based denoising of spectral domain optical coherence tomography images
Fang, L., Li, S., Nie, Q., Izatt, J. A., Toth, C. A., & Farsiu, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000927 · Cited by 268
Self-citationFast Acquisition and Reconstruction of Optical Coherence Tomography Images via Sparse Representation
Fang, L., Li, S., McNabb, R. P., Nie, Q., Kuo, A. N., Toth, C. A., Izatt, J. A., & Farsiu, S. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2271904 · Cited by 247
“To attain an HH image in the reference (learning) dataset, we employed a customized scanning pattern in which a sequence of densely sampled, repeated low-SNR-high-resolution (LH) B-scans from spatially very close positions are captured, registered, and averaged to create an HH image [37], [38].”
MethodSelf-citationKiernan, D. F., Mieler, W. F., & Hariprasad, S. M. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.08.037 · Cited by 246
Vajzovic, L., Hendrickson, A. E., O'Connell, R. V., Clark, L. A., Tran-Viet, D., Possin, D., Chiu, S. J., Farsiu, S., & Toth, C. A. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2012.05.004 · Cited by 238
Self-citationDynamics of Human Foveal Development after Premature Birth
Maldonado, R. S., O'Connell, R. V., Sarin, N., Freedman, S. F., Wallace, D. K., Cotten, C. M., Winter, K. P., Stinnett, S., Chiu, S. J., Izatt, J. A., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.05.028 · Cited by 218
Self-citationChavala, S. H., Farsiu, S., Maldonado, R., Wallace, D. K., Freedman, S. F., & Toth, C. A. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.06.003 · Cited by 172
Self-citationDAYANI, P. N., MALDONADO, R., FARSIU, S., & TOTH, C. A. (2009) · Retina · doi:10.1097/iae.0b013e3181b266bc · Cited by 160
Self-citationIntraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Metadata
- Authors
- Scott, A. W., Farsiu, S., Enyedi, L. B., Wallace, D. K., & Toth, C. A.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 147
- Issue
- 2
- Pages
- 364-373.e2
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2050341950
- Cited by
- 177
- References
- 10
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.