Glaucoma Screening in Nepal: Cup-to-Disc Estimate With Standard Mydriatic Fundus Camera Compared to Portable Nonmydriatic Camera
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose To compare cup to disc ratio (CDR) measurements from images taken with a portable, 45° non-mydriatic fundus camera to images from a traditional table-top mydriatic fundus camera. Design Prospective, cross sectional, comparative instrument validation study. Methods Setting Clinic-based. Study Population 422 eyes of 211 subjects were recruited from the Tilganga Institute of Ophthalmology (Kathmandu, Nepal). Two masked readers measured CDR and noted possible evidence of glaucoma (CDR ≥0.7 or the presence of a notch or disc hemorrhage) from fundus photographs taken with a non-mydriatic portable camera and a mydriatic standard camera. Each image was graded twice. Main Outcome Measures Effect of camera modality on CDR measurement, inter- and intra-observer agreement for each camera for the diagnosis of glaucoma. Results 196 eyes (46.5%) were diagnosed with glaucoma by chart review. 41.2%–59.0% of eyes were remotely diagnosed with glaucoma over grader, repeat measurement, and camera modality. There was no significant difference in CDR measurement between cameras after adjusting for grader and measurement order (estimate=0.004, 95% confidence interval (CI), 0.003–0.011, p=0.24). There was moderate inter-observer reliability for the diagnosis of glaucoma (Pictor (κ=0.54, CI, 0.46–0.61); Topcon (κ=0.63, CI, 0.55–0.70) and moderate intra-observer agreement upon repeat grading (Pictor (κ=0.63 and 0.64, for Graders 1 and 2, respectively); Topcon (κ=0.72 and 0.80, for Graders 1 and 2, respectively). Conclusions A portable, non-mydriatic, fundus camera can facilitate remote evaluation of disc images on par with standard mydriatic fundus photography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040
Tham, Y.-C., Li, X., Wong, T. Y., Quigley, H. A., Aung, T., & Cheng, C.-Y. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.013 · Cited by 7,159
Racial Differences in the Cause-Specific Prevalence of Blindness in East Baltimore
Sommer, A., Tielsch, J. M., Katz, J., Quigley, H. A., Gottsch, J. D., Javitt, J. C., Martone, J. F., Royall, R. M., Witt, K. A., & Ezrine, S. (1991) · New England Journal of Medicine · doi:10.1056/nejm199111143252004 · Cited by 764
Muñoz, B. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.6.819 · Cited by 521
Prevalence of open-angle glaucoma and ocular hypertension in Latinos
Varma, R., Ying-Lai, M., Francis, B. A., Nguyen, B. B.-T., Deneen, J., Wilson, M. R., & Azen, S. P. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.01.025 · Cited by 483
Cited by
Li, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830
Digital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“Thus, detection of early disease requires experienced ophthalmologists curtailing the cost-effectiveness in glaucoma screening (Fleming et al., 2005; Moyer et al., 2013; Miller et al., 2017; Pizzi et al., 2018).”
BackgroundChristopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
A Review of Deep Learning for Screening, Diagnosis, and Detection of Glaucoma Progression
Thompson, A. C., Jammal, A. A., & Medeiros, F. A. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.42 · Cited by 195
Metadata
- Authors
- Miller, S. E., Thapa, S., Robin, A. L., Niziol, L. M., Ramulu, P. Y., Woodward, M. A., Paudyal, I., Pitha, I., Kim, T. N., & Newman-Casey, P. A.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 182
- Pages
- 99-106
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2739090751
- Cited by
- 42
- References
- 4
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glaucoma Screening in Nepal: Cup-to-Disc Estimate With Standard Mydriatic Fundus Camera Compared to Portable Nonmydriatic Camera. https://app.cochat.ai/papers/10.1016/j.ajo.2017.07.010
- The paper
- Miller, S. E., Thapa, S., Robin, A. L., Niziol, L. M., Ramulu, P. Y., Woodward, M. A., Paudyal, I., Pitha, I., Kim, T. N., & Newman-Casey, P. A. (2017). Glaucoma Screening in Nepal: Cup-to-Disc Estimate With Standard Mydriatic Fundus Camera Compared to Portable Nonmydriatic Camera. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2017.07.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.