Reproducibility of Vessel Density, Fractal Dimension, and Foveal Avascular Zone Using 7 Different Optical Coherence Tomography Angiography Devices
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spaide, R. F., Klancnik, J. M., & Cooney, M. J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.3616 · Cited by 1,620
A review of optical coherence tomography angiography (OCTA)
de Carlo, T. E., Romano, A., Waheed, N. K., & Duker, J. S. (2015) · International Journal of Retina and Vitreous · doi:10.1186/s40942-015-0005-8 · Cited by 1,126
Kim, A. Y., Chu, Z., Shahidzadeh, A., Wang, R. K., Puliafito, C. A., & Kashani, A. H. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18904 · Cited by 502
Balaratnasingam, C., Inoue, M., Ahn, S., McCann, J., Dhrami-Gavazi, E., Yannuzzi, L. A., & Freund, K. B. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.07.008 · Cited by 367
Fractal Analysis of the Vascular Tree in the Human Retina
Masters, B. R. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140100 · Cited by 316
Quantitative Confocal Imaging of the Retinal Microvasculature in the Human Retina
Tan, P. E. Z., Yu, P. K., Balaratnasingam, C., Cringle, S. J., Morgan, W. H., McAllister, I. L., & Yu, D.-Y. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10017 · Cited by 205
Quantitative Morphometry of Perifoveal Capillary Networks in the Human Retina
Chan, G., Balaratnasingam, C., Yu, P. K., Morgan, W. H., McAllister, I. L., Cringle, S. J., & Yu, D.-Y. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10265 · Cited by 195
Al‐Sheikh, M., Tepelus, T. C., Nazikyan, T., & Sadda, S. R. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308764 · Cited by 154
You, Q. S., Freeman, W. R., Weinreb, R. N., Zangwill, L. M., Manalastas, P. I. C., Saunders, L. J., & Nudleman, E. (2016) · Retina · doi:10.1097/iae.0000000000001407 · Cited by 136
Zhang, Q., Chen, C., Chu, Z., Zheng, F., Miller, A., Roisman, L., Dias, J. R. D. O., Yehoshua, Z., Schaal, K. B., Feuer, W. J., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20977 · Cited by 108
Guo, J., She, X., Liu, X., et al. (2017) · Ophthalmologica · doi:10.1159/000453112 · Cited by 53
Cited by
Towards standardizing retinal optical coherence tomography angiography: a review
Sampson, D. M., Dubis, A. M., Chen, F. K., Zawadzki, R. J., & Sampson, D. D. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00740-9 · Cited by 179
The eye, the kidney, and cardiovascular disease: old concepts, better tools, and new horizons
Farrah, T. E., Dhillon, B., Keane, P. A., Webb, D. J., & Dhaun, N. (2020) · Kidney International · doi:10.1016/j.kint.2020.01.039 · Cited by 171
“with unique retinal layer segmentation algorithms and so metrics are not interchangeable across devices.(157,158) Finally, maximizing the yield of data from complex OCT and OCT-A images will require similar advancement and investment in imaging analysis methodology, which, given the advent of artificial intelligence i…”
BackgroundA New Approach to Staging Diabetic Eye Disease
Channa, R., Wolf, R. M., Simo, R., Brigell, M., Fort, P., Curcio, C., Lynch, S., Verbraak, F., Abramoff, M. D., Abramoff, M. D., et al. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2023.100420 · Cited by 26
“76 e 78 With improved technology, artifacts associated with OCTA have decreased, but the presence of DME makes OCTA measurements less reliable.”
Metadata
- Authors
- Corvi, F., Pellegrini, M., Erba, S., Cozzi, M., Staurenghi, G., & Giani, A.
- Venue
- American Journal of Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 186
- Pages
- 25-31
- ISSN
- 0002-9394 (ISSN-L)
- OpenAlex
- W2768390170
- Cited by
- 219
- References
- 11
- FWCI
- 22.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.