Superimposition of 3-dimensional cone-beam computed tomography models of growing patients
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Introduction The objective of this study was to evaluate a new method for superimposition of 3-dimensional (3D) models of growing subjects. Methods Cone-beam computed tomography scans were taken before and after Class III malocclusion orthopedic treatment with miniplates. Three observers independently constructed 18 3D virtual surface models from cone-beam computed tomography scans of 3 patients. Separate 3D models were constructed for soft-tissue, cranial base, maxillary, and mandibular surfaces. The anterior cranial fossa was used to register the 3D models of before and after treatment (about 1 year of follow-up). Results Three-dimensional overlays of superimposed models and 3D color-coded displacement maps allowed visual and quantitative assessment of growth and treatment changes. The range of interobserver errors for each anatomic region was 0.4 mm for the zygomatic process of maxilla, chin, condyles, posterior border of the rami, and lower border of the mandible, and 0.5 mm for the anterior maxilla soft-tissue upper lip. Conclusions Our results suggest that this method is a valid and reproducible assessment of treatment outcomes for growing subjects. This technique can be used to identify maxillary and mandibular positional changes and bone remodeling relative to the anterior cranial fossa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 2×
“htm) computes the rigid registration (translation and rotation) that optimally aligns before and after treatment gray level CBCT data sets with subvoxel accuracy at the anterior cranial base.(15) The registration used the best anatomic fit of anterior cranial base structures that have completed growth by age 7(7,16-18…”
Method
Cited by
Li, L., Liu, H., Cheng, H., Han, Y., Wang, C., Chen, Y., Song, J., & Liu, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094378 · Cited by 92
Gazzani, F., Ruellas, A. C. D. O., Faltin, K., Franchi, L., Cozza, P., Bigliazzi, R., Cevidanes, L. H. S., & Lione, R. (2018) · BioMed Research International · doi:10.1155/2018/2568235 · Cited by 17
“3D analysis allows the clinician to rotate the 3D volumes and to observe multiple views in space rather than one sagittal view [8, 16].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Cevidanes, L. H. C., Heymann, G., Cornelis, M. A., DeClerck, H. J., & Tulloch, J. F. C.
- Venue
- American Journal of Orthodontics and Dentofacial Orthopedics
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 136
- Issue
- 1
- Pages
- 94-99
- ISSN
- 0889-5406 (ISSN-L)
- OpenAlex
- W2096834599
- Cited by
- 198
- References
- 2
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.