Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective To quantify fetal cardiovascular parameters with Spatio-Temporal Image Correlation (STIC) and Virtual Organ Computed-aided AnaLysis (VOCAL™) utilizing the sub-feature: “Contour Finder: Trace”. Study Design A cross-sectional study was designed consisting of patients with normal pregnancies between 19 and 40 weeks of gestation. After STIC datasets were acquired, analysis was performed offline (4DView) and the following cardiovascular parameters were evaluated: ventricular volume in end systole and end diastole, stroke volume, cardiac output, and ejection fraction. To account for fetal size, cardiac output was also expressed as a function of head circumference, abdominal circumference, or femoral diaphysis length. Regression models were fitted for each cardiovascular parameter to assess the effect of gestational age and paired comparisons were made between the left and right ventricles. Results 1) Two hundred and seventeen patients were retrospectively identified, of whom 184 had adequate STIC datasets (85% acceptance); 2) ventricular volume, stroke volume, cardiac output, and adjusted cardiac output increased with gestational age; whereas, the ejection fraction decreased as gestation advanced; 3) the right ventricle was larger than the left in both systole (Right: 0.50 ml, IQR: 0.2 – 0.9; vs. Left: 0.27 ml, IQR: 0.1 – 0.5; p<0.001) and diastole (Right: 1.20 ml, IQR: 0.7 – 2.2; vs. Left: 1.03 ml, IQR: 0.5 – 1.7; p<0.001); 4) there were no differences between the left and right ventricle with respect to stroke volume, cardiac output, or adjusted cardiac output; and 5) the left ventricular ejection fraction was greater than the right (Left: 72.2%, IQR: 64 – 78; vs. Right: 62.4%, IQR: 56 – 69; p<0.001). Conclusion Fetal echocardiography, utilizing STIC and VOCAL™ with the sub-feature: “Contour Finder: Trace”, allows assessment of fetal cardiovascular parameters. Normal fetal cardiovascular physiology is characterized by ventricular volumes that are larger on the right and ejection fractions that are greater for the left ventricle resulting in similar left and right ventricular stroke volume and cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Spatio‐temporal image correlation (STIC): new technology for evaluation of the fetal heart
DeVore, G. R., Falkensammer, P., Sklansky, M. S., & Platt, L. D. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.217 · Cited by 362
Progression of Doppler abnormalities in intrauterine growth restriction
Turan, O. M., Turan, S., Gungor, S., Berg, C., Moyano, D., Gembruch, U., Nicolaides, K. H., Harman, C. R., & Baschat, A. A. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5386 · Cited by 353
Ecology and energetics of encephalization in hominid evolution
Foley, R. A., & Lee, P. C. (1991) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1991.0111 · Cited by 244
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
“Nevertheless, various applications of this technology have enhanced the quantitative measurement of fetal cardiac chamber volumes and ejection fractions.(253) Clinically, the technique has the potential to improve screening of low-risk pregnancies for CHD, particularly when combined with telemedicine and algorithms to…”
MethodSelf-citationYeo, L., & Romero, R. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12563 · Cited by 110
Self-citationUltrasound assessment of fetal cardiac function
Crispi, F., Valenzuela‐Alcaraz, B., Cruz‐Lemini, M., & Gratacós, E. (2013) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/j.2205-0140.2013.tb00242.x · Cited by 70
Gembicki, M., Hartge, D. R., Dracopoulos, C., & Weichert, J. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15105 · Cited by 31
Metadata
- Authors
- Hamill, N., Yeo, L., Romero, R., Hassan, S. S., Myers, S. A., Mittal, P., Kusanovic, J. P., Balasubramaniam, M., Chaiworapongsa, T., Vaisbuch, E., Espinoza, J., Gotsch, F., Goncalves, L. F., & Lee, W.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 205
- Issue
- 1
- Pages
- 76.e1-76.e10
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W2043135690
- Cited by
- 85
- References
- 4
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.