CoChat

Cervical pessary to prevent preterm birth in women with twin gestation and sonographic short cervix: a multicenter randomized controlled trial (PECEP-Twins)

Open access
Goya, Maria, de la Calle, Maria, Pratcorona, Laia, Merced, Carme, Rodó, Carlota, Muñoz, Begoña, Juan, Miquel, Serrano, Ariana, Llurba, Elisa, Higueras, Teresa, Carreras, Elena, Cabero, Luis, Arevalo, Silvia, Aviles, Maite, Calero, Ines, Casellas, Manuel, Folch, Marina, García, Itziar, Sanchez, Maria A., Sagalá, Juan, Suy, Anna, Magdaleno, Fernando, Bartha, Jose Luis, Pascual, Josep R., Inglés, Montserrat, Cavallé, Pere, Comas, Carmina · 2016 · American Journal of Obstetrics and Gynecology
Cited by 219

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

BACKGROUND Spontaneous preterm birth (SPB) is the leading cause of perinatal morbidity and mortality. In twins, the rate of preterm birth is higher than in singletons; interventions to prevent preterm birth are needed in this high-risk population. OBJECTIVE We sought to test whether a cervical pessary reduces the preterm birth rate in twin pregnancies with sonographic short cervix. STUDY DESIGN A prospective, open-label, multicenter, randomized clinical trial was conducted in 5 hospitals in Spain. The ethics committees of all participating hospitals approved the protocol. The trial was registered as ClinicalTrials.gov, number NCT01242410. Eligible women were scanned in Spain. The primary outcome was SPB <34 weeks of gestation. Neonatal morbidity and mortality were also evaluated. RESULTS Cervical length was measured in 2287 women; 137 pregnant women with a sonographic cervical length ≤25 mm (of 154 detected with a short cervix) were randomly assigned to receive a cervical pessary or expectant management (1:1 ratio). SPB <34 weeks of gestation was significantly less frequent in the pessary group than in the expectant management group (11/68 [16.2%] vs 26/66 [39.4%]; relative risk, 0.41; 95% confidence interval, 0.22-0.76). Pessary use was associated with a significant reduction in the rate of birthweight <2500 g (P = .01). No significant differences were observed in composite neonatal morbidity outcome (8/136 [5.9%] vs 12/130 [9.1%]; relative risk, 0.64; 95% confidence interval, 0.27-1.50) or neonatal mortality (none) between the groups. No serious adverse effects associated with the use of a cervical pessary were observed. CONCLUSION The insertion of a cervical pessary was associated with a significant reduction in the SPB rate. We propose the use of a cervical pessary for preventing preterm birth in twin pregnancies of mothers with a short cervix.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajog.2015.11.012

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 219

Metadata

Authors
Goya, M., de la Calle, M., Pratcorona, L., Merced, C., Rodó, C., Muñoz, B., Juan, M., Serrano, A., Llurba, E., Higueras, T., Carreras, E., Cabero, L., Arevalo, S., Aviles, M., Calero, I., Casellas, M., Folch, M., García, I., Sanchez, M. A., Sagalá, J., Suy, A., Magdaleno, F., Bartha, J. L., Pascual, J. R., Inglés, M., Cavallé, P., & Comas, C.
Venue
American Journal of Obstetrics and Gynecology
Publisher
Elsevier BV
Published
2016-02
Volume
214
Issue
2
Pages
145-152
ISSN
0002-9378 (ISSN-L)
OpenAlex
W2180466195
Cited by
219
References
33
FWCI
25.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.