Hydralazine vs nifedipine for acute hypertensive emergency in pregnancy: a randomized controlled trial
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background There is a paucity of good quality evidence regarding the best therapeutic option for acute control of blood pressure during acute hypertensive emergency of pregnancy. Objective We sought to compare the efficacy of intravenously administered hydralazine and oral nifedipine for acute blood pressure control in acute hypertensive emergency of pregnancy. Study Design In this double‐blind, randomized, controlled trial, pregnant women (≥24 weeks period of gestation) with sustained increase in systolic blood pressure of ≥160 mm Hg or diastolic blood pressure of ≥110 mm Hg were randomized to receive intravenous hydralazine injection in doses of 5, 10, 10, and 10 mg and a placebo tablet or oral nifedipine (10 mg tablet up to 4 doses) and intravenous saline injection every 20 minutes until the target blood pressure of 150 mm Hg systolic and ≤100 mm Hg diastolic was achieved. Crossover treatment was administered if the initial treatment failed. The primary outcome of the study was time necessary to achieve target blood pressure. The secondary outcomes were the number of dosages required, adverse maternal and neonatal effects, and perinatal outcome. Results From December 2014 through September 2015, we enrolled 60 patients. The median time to achieve target blood pressure was 40 minutes in both groups (intravenous hydralazine and oral nifedipine) (interquartile interval 5 and 40 minutes, respectively, P = .809). The median dose requirement in both groups was 2 (intravenous hydralazine and oral nifedipine) (interquartile range 1 and 2 doses, respectively, P = .625). Intravenous hydralazine was associated with statistically significantly higher occurrence of vomiting (9/30 vs 2/30, respectively, P = .042). No serious adverse maternal or perinatal side effects were witnessed in either group. Conclusion Both intravenous hydralazine and oral nifedipine are equally effective in lowering of blood pressure in acute hypertensive emergency of pregnancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CONSORT 2010 Statement: Updated Guidelines for Reporting Parallel Group Randomized Trials
Schulz, K. F., Altman, D. G., & Moher, D. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181d9d421 · Cited by 519
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
ACOG Practice Bulletin No. 203: Chronic Hypertension in Pregnancy
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003020 · Cited by 871
Gestational Hypertension and Preeclampsia: An Overview of National and International Guidelines
Tsakiridis, I., Giouleka, S., Arvanitaki, A., Giannakoulas, G., Papazisis, G., Mamopoulos, A., Athanasiadis, A., & Dagklis, T. (2021) · Obstetrical & Gynecological Survey · doi:10.1097/ogx.0000000000000942 · Cited by 64
Metadata
- Authors
- Sharma, C., Soni, A., Gupta, A., Verma, A., & Verma, S.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 217
- Issue
- 6
- Pages
- 687.e1-687.e6
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W2752490304
- Cited by
- 43
- References
- 1
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.