CoChat

Special Report of the Society for Maternal-Fetal Medicine Placenta Accreta Spectrum Ultrasound Marker Task Force: Consensus on definition of markers and approach to the ultrasound examination in pregnancies at risk for placenta accreta spectrum

Open access
Shainker, Scott A., Coleman, Beverly, Timor-Tritsch, Ilan E., Bhide, Amarnath, Bromley, Bryann, Cahill, Alison G., Gandhi, Manisha, Hecht, Jonathan L., Johnson, Katherine M., Levine, Deborah, Mastrobattista, Joan, Philips, Jennifer, Platt, Lawrence D., Shamshirsaz, Alireza A., Shipp, Thomas D., Silver, Robert M., Simpson, Lynn L., Copel, Joshua A., Abuhamad, Alfred · 2021 · American Journal of Obstetrics and Gynecology
Cited by 159

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Placenta accreta spectrum includes the full range of abnormal placental attachment to the uterus or other structures, encompassing placenta accreta, placenta increta, placenta percreta, morbidly adherent placenta, and invasive placentation. The incidence of placenta accreta spectrum has increased in recent years, largely driven by increasing rates of cesarean delivery. Prenatal detection of placenta accreta spectrum is primarily made by ultrasound and is important to reduce maternal morbidity associated with the condition. Despite a large body of research on various placenta accreta spectrum ultrasound markers and their screening performance, inconsistencies in the literature persist. In response to the need for standardizing the definitions of placenta accreta spectrum markers and the approach to the ultrasound examination, the Society for Maternal-Fetal Medicine convened a task force with representatives from the American Institute of Ultrasound in Medicine, the American College of Obstetricians and Gynecologists, the American College of Radiology, the International Society of Ultrasound in Obstetrics and Gynecology, the Society for Radiologists in Ultrasound, the American Registry for Diagnostic Medical Sonography, and the Gottesfeld-Hohler Memorial Ultrasound Foundation. The goals of the task force were to assess placenta accreta spectrum sonographic markers on the basis of available data and expert consensus, provide a standardized approach to the prenatal ultrasound evaluation of the uterus and placenta in pregnancies at risk of placenta accreta spectrum, and identify research gaps in the field. This manuscript provides information on the Placenta Accreta Spectrum Task Force process and findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajog.2020.09.001

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 159

Metadata

Authors
Shainker, S. A., Coleman, B., Timor-Tritsch, I. E., Bhide, A., Bromley, B., Cahill, A. G., Gandhi, M., Hecht, J. L., Johnson, K. M., Levine, D., Mastrobattista, J., Philips, J., Platt, L. D., Shamshirsaz, A. A., Shipp, T. D., Silver, R. M., Simpson, L. L., Copel, J. A., & Abuhamad, A.
Venue
American Journal of Obstetrics and Gynecology
Publisher
Elsevier BV
Published
2021-01
Volume
224
Issue
1
Pages
B2-B14
ISSN
0002-9378 (ISSN-L)
OpenAlex
W3116279953
Cited by
159
References
15
FWCI
16.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.